The Effect of Aortic Angulation on Clinical Outcomes of Patients Undergoing Transcatheter Aortic Valve Replacement

被引:3
作者
Aktan, Adem [1 ]
Demir, Muhammed [2 ]
Guzel, Tuncay [3 ]
Karahan, Mehmet Zulkuf [4 ]
Aslan, Burhan [3 ]
Kilic, Raif [5 ]
Gunlu, Serhat [6 ]
Arslan, Bayram [7 ]
Ozbek, Mehmet [2 ]
Ertas, Faruk [2 ]
机构
[1] Mardin Training & Res Hosp, Dept Cardiol, Vali Ozan St, TR- 47000 Mardin, Turkiye
[2] Dicle Univ, Fac Med, Dept Cardiol, Diyarbakir, Turkiye
[3] Hlth Sci Univ, Gazi Yasargil Training & Res Hosp, Dept Cardiol, Diyarbakir, Turkiye
[4] Mardin Artuklu Univ, Fac Med, Dept Cardiol, Mardin, Turkiye
[5] Diyarlife Hosp, Dept Cardiol, Diyarbakir, Turkiye
[6] Baglar State Hosp, Dept Cardiol, Diyarbakir, Turkiye
[7] Ergani State Hosp, Dept Cardiol, Diyarbakir, Turkiye
关键词
Aortic Angulation; Aortic Stenosis; Transcatheter Aortic Valve Replacement; Logistic Models; 3-DIMENSIONAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; LEFT-VENTRICLE; IMPLANTATION; REGURGITATION; TAVR; ASSOCIATION; SOCIETY; UPDATE;
D O I
10.21470/1678-9741-2022-0436
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The aim of this study was to assess the impact of aortic angulation (AA) on periprocedural and in -hospital complications as well as mortality of patients undergoing Evolut (TM) R valve implantation. Methods: A retrospective study was conducted on 264 patients who underwent transfemoral-approach transcatheter aortic valve replacement with self-expandable valve at our hospital between August 2015 and August 2022. These patients underwent multislice computer tomography scans to evaluate AA. Transcatheter aortic valve replacement endpoints, device success, and clinical events were assessed according to the definitions provided by the Valve Academic Research Consortium -3. Cumulative events included paravalvular leak, permanent pacemaker implantation, new-onset stroke, and in -hospital mortality. Patients were divided into two groups, AA <= 48(degrees) and AA > 48(degrees), based on the mean AA measurement (48.3 +/- 8.8) on multislice computer tomography. Results: Multivariable logistic regression analysis was performed to identify predictors of cumulative events, utilizing variables with a P-value < 0.2 obtained from univariable logistic regression analysis, including AA, age, hypertension, chronic renal failure, and heart failure. AA (odds ratio [OR]: 1.73, 95% confidence interval [CI]: 0.89-3.38, P=0.104), age (OR: 1.04, 95% CI: 0.99-1.10, P=0.099), hypertension (OR: 1.66, 95% CI: 0.82-3.33, P=0.155), chronic renal failure (OR: 1.82, 95% CI: 0.92-3.61, P=0.084), and heart failure (OR: 0.57, 95% CI: 0.27-1.21, P=0.145) were not found to be significantly associated with cumulative events in the multivariable logistic regression analysis. Conclusion: This study demonstrated that increased AA does not have a significant impact on intraprocedural and periprocedural complications of patients with new generation self-expandable valves implanted.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Aortic Angulation Attenuates Procedural Success Following Self-Expandable But Not Balloon-Expandable TAVR [J].
Abramowitz, Yigal ;
Maeno, Yoshio ;
Chakravarty, Tarun ;
Kazuno, Yoshio ;
Takahashi, Nobuyuki ;
Kawamori, Hiroyuki ;
Mangat, Geeteshwar ;
Cheng, Wen ;
Jilaihawi, Hasan ;
Makkar, Raj R. .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) :964-972
[2]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[3]   Hypertrophic Left Ventricle With Small Cavity and Severe Aortic Angulation A Dangerous Association in Case of Transcatheter Aortic Valve Replacement [J].
Ancona, Marco B. ;
Hachinohe, Daisuke ;
Giannini, Francesco ;
Del Sole, Paolo A. ;
Regazzoli, Damiano ;
Mangieri, Antonio ;
Romano, Vittorio ;
Latib, Azeem ;
Ancona, Francesco ;
Monaco, Fabrizio ;
Castiglioni, Alessandro ;
Esposito, Antonio ;
Montorfano, Matteo ;
Colombo, Antonio .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) :E29-E30
[4]  
Aslan S, 2022, Koşuyolu Heart Journal, V25, P132, DOI 10.51645/khj.2022.m244
[5]   Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography [J].
Blanke, Philipp ;
Weir-McCall, Jonathan R. ;
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Jilaihawi, Hasan ;
Marwan, Mohamed ;
Norgaard, Bjarne L. ;
Piazza, Niccolo ;
Schoenhagen, Paul ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) :1-20
[6]   Correlation Between Aortic Angulation and Outcomes of Transcatheter Aortic Valve Replacement With New-Generation Valves [J].
Bob-Manuel, Tamunoinemi ;
Pour-Ghaz, Issa ;
Sharma, Arindam ;
Chinta, Viswanatha R. ;
Abader, Peter ;
Paulus, Basil ;
Khouzam, Rami N. ;
Ibebuogu, Uzoma N. .
CURRENT PROBLEMS IN CARDIOLOGY, 2021, 46 (02)
[7]  
Généreux P, 2021, EUR HEART J, V42, P1825, DOI [10.1093/eurheartj/ehaa799, 10.1016/j.jacc.2021.02.038]
[8]   Evolut Self-Expanding Transcatheter Aortic Valve Replacement in Patients with Extremely Horizontal Aorta (Aortic Root Angle ≥ 70°) Technical Aspects and Clinical Outcomes [J].
Kaneko, Umihiko ;
Hachinohe, Daisuke ;
Kobayashi, Ken ;
Shitan, Hidemasa ;
Mitsube, Keijiro ;
Furugen, Azusa ;
Kawamura, Takeshi ;
Koshima, Ryuji ;
Fujita, Tsutomu .
INTERNATIONAL HEART JOURNAL, 2020, 61 (05) :1059-1069
[9]   Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging [J].
Lang, Roberto M. ;
Badano, Luigi P. ;
Mor-Avi, Victor ;
Afilalo, Jonathan ;
Armstrong, Anderson ;
Ernande, Laura ;
Flachskampf, Frank A. ;
Foster, Elyse ;
Goldstein, Steven A. ;
Kuznetsova, Tatiana ;
Lancellotti, Patrizio ;
Muraru, Denisa ;
Picard, Michael H. ;
Rietzschel, Ernst R. ;
Rudski, Lawrence ;
Spencer, Kirk T. ;
Tsang, Wendy ;
Voigt, Jens-Uwe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (03) :233-271
[10]   Imaging in Transcatheter Aortic Valve Replacement (TAVR): Role of the radiologist [J].
Litmanovich D.E. ;
Ghersin E. ;
Burke D.A. ;
Popma J. ;
Shahrzad M. ;
Bankier A.A. .
Insights into Imaging, 2014, 5 (1) :123-145