摘要
The aim of this study was to validate a method for determining nine types of steviol glycoside and its derivatives in food and beverage products, using ultrahigh-performance liquid chromatography tandem mass spectrometry with electrospray ionization (UHPLC ESI MS/MS). The performance characteristics of the analysis method were determined along with their suitability for the intended use. Coefficient of determination (R2) calibration curves from 0.2 to 1.0 mg L-1 were in the ranges of 0.9911-0.9990, 0.9939-1.0000 and 0.9973-0.9999 for a beverage, yogurt and snack, respectively. Intra-day precisions in terms of percent relative standard deviation (% RSD) of concentration, at 0.2, 0.5 and 1.0 mg L-1, for the beverage, yogurt and snack were lower than 15% (1.1-9.3%). At all concentrations, percentage recoveries were in the accepted range of 70-120%. For the matrix effect study, matrix-matched calibration was used for all compounds, obtaining a linear concentration range from 0.2 mg L-1 to 1.0 mg L-1. Almost all matrix-matched results presented as percentage recoveries were within the accepted range of 80-120%. The limit of detection (LOD) for steviol glycosides ranged from 0.003 to 0.078 mu g g-1, while the limit of quantitation (LOQ) ranged from 0.011 to 0.261 mu g g-1. These results indicate that the modified test method can be applied to determine the presence of steviol glycoside and its derivatives in a wide range of sample matrices.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Development and validation of a rapid LC-ESI-MS/MS method for quantification of fluoxetine and its application to MS binding assays
    Hess, Marielle
    Hoefner, Georg
    Wanner, Klaus Theodor
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (10) : 3505 - 3515
  • [32] Rapid Characterization of Insulin Modifications and Sequence Variations by Proteinase K Digestion and UHPLC-ESI-MS
    Yang, Rong-Sheng
    Tang, Weijuan
    Sheng, Huaming
    Meng, Fanyu
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (05) : 853 - 858
  • [33] Effects of Antioxidants on Rapeseed Oil Oxidation in an Artificial Digestion Model Analyzed by UHPLC-ESI-MS
    Tarvainen, Marko
    Phuphusit, Aleksandra
    Suomela, Jukka-Pekka
    Kuksis, Arnis
    Kallio, Heikki
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (14) : 3564 - 3579
  • [34] Development of a Bioanalytical Method by UHPLC-ESI-TQD-MS for the Quantification of Digoxin in Plasma
    Agrawal, Gopal Prasad
    Soni, Kanchan
    REVISTA BRASILEIRA DE FARMACOGNOSIA-BRAZILIAN JOURNAL OF PHARMACOGNOSY, 2023, 33 (04): : 747 - 755
  • [35] High-Throughput Assay of Oleopentanedialdheydes in Extra Virgin Olive Oil by the UHPLC-ESI-MS/MS and Isotope Dilution Methods
    Di Donna, Leonardo
    Benabdelkamel, Hicham
    Mazzotti, Fabio
    Napoli, Anna
    Nardi, Monica
    Sindona, Giovanni
    ANALYTICAL CHEMISTRY, 2011, 83 (06) : 1990 - 1995
  • [36] One step salting-out assisted liquid-liquid extraction followed by UHPLC-ESI-MS/MS for the analysis of isoflavones in soy milk
    Park, Hee Jeong
    Jung, Mun Yhung
    FOOD CHEMISTRY, 2017, 229 : 797 - 804
  • [37] Novel in-source fragments used to identify linear microcystins with C-terminal arginine by UHPLC-ESI-MS/MS
    Thenuwara, Sharmila I.
    Westrick, Judy A.
    Isailovic, Dragan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 500
  • [38] Determination and pharmacokinetic study of two triterpenoid saponins in rat plasma after oral administration of the extract of Aralia elata leaves by UHPLC-ESI-MS/MS
    Wang, Zhibin
    Wu, Qiong
    Meng, Yonghai
    Sun, Yichun
    Wang, Qi
    Yang, Chunjuan
    Wang, Qiuhong
    Yang, Bingyou
    Kuang, Haixue
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 985 : 164 - 171
  • [39] An ultrasensitive UHPLC-ESI-MS/MS method augmented with a controlled microwave derivatization reaction for quantitation of vitamin D3 and its major metabolites in COVID-19 patients
    Ahmed, Sameh A.
    Khojah, Hani M. J.
    Al-Thagfan, Sultan S.
    Alahmadi, Yaser M.
    Mohammed, Yasser A.
    TALANTA, 2022, 246
  • [40] Development of a targeted method for twenty-three metabolites related to polyphenol gut microbial metabolism in biological samples, using SPE and UHPLC-ESI-MS/MS
    Gasperotti, Mattia
    Masuero, Domenico
    Guella, Graziano
    Mattivi, Fulvio
    Vrhovsek, Urska
    TALANTA, 2014, 128 : 221 - 230