Validation of UHPLC-ESI-MS/MS Method for Determining Steviol Glycoside and Its Derivatives in Foods and Beverages

被引:3
作者
Phungsiangdee, Yollada [1 ,2 ]
Chaothong, Pimpuk [2 ]
Karnpanit, Weeraya [3 ]
Tanaviyutpakdee, Pharrunrat [2 ]
机构
[1] Mahidol Univ, Inst Nutr, Master Sci Program Toxicol & Nutr Food Safety, Nakhon Pathom 73170, Thailand
[2] Mahidol Univ, Food Toxicol Unit, Inst Nutr, Putthamonthon 73170, Nakhon Pathom, Thailand
[3] Western Sydney Univ, Sch Sci, Locked Bag 1797, Penrith, NSW 2751, Australia
关键词
steviol glycoside; UHPLC-ESI-MS/MS; validation of method; foods and beverages; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; ELECTROSPRAY-IONIZATION; REBAUDIANA BERTONI; CORE-SHELL; PREPARATIVE SEPARATION; DITERPENE GLYCOSIDES; HPLC METHOD; PERFORMANCE;
D O I
10.3390/foods12213941
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The aim of this study was to validate a method for determining nine types of steviol glycoside and its derivatives in food and beverage products, using ultrahigh-performance liquid chromatography tandem mass spectrometry with electrospray ionization (UHPLC ESI MS/MS). The performance characteristics of the analysis method were determined along with their suitability for the intended use. Coefficient of determination (R2) calibration curves from 0.2 to 1.0 mg L-1 were in the ranges of 0.9911-0.9990, 0.9939-1.0000 and 0.9973-0.9999 for a beverage, yogurt and snack, respectively. Intra-day precisions in terms of percent relative standard deviation (% RSD) of concentration, at 0.2, 0.5 and 1.0 mg L-1, for the beverage, yogurt and snack were lower than 15% (1.1-9.3%). At all concentrations, percentage recoveries were in the accepted range of 70-120%. For the matrix effect study, matrix-matched calibration was used for all compounds, obtaining a linear concentration range from 0.2 mg L-1 to 1.0 mg L-1. Almost all matrix-matched results presented as percentage recoveries were within the accepted range of 80-120%. The limit of detection (LOD) for steviol glycosides ranged from 0.003 to 0.078 mu g g-1, while the limit of quantitation (LOQ) ranged from 0.011 to 0.261 mu g g-1. These results indicate that the modified test method can be applied to determine the presence of steviol glycoside and its derivatives in a wide range of sample matrices.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Comprehensive assay of flavanones in citrus juices and beverages by UHPLC-ESI-MS/MS and derivatization chemistry
    Di Donna, Leonardo
    Taverna, Domenico
    Mazzotti, Fabio
    Benabdelkamel, Hicham
    Attya, Mohamed
    Napoli, Anna
    Sindona, Giovanni
    FOOD CHEMISTRY, 2013, 141 (03) : 2328 - 2333
  • [2] Development and validation of UHPLC-ESI-MS/MS method for the determination of selected cardiovascular drugs, polyphenols and their metabolites in human urine
    Magiera, Sylwia
    Baranowska, Irena
    Kusa, Jacek
    TALANTA, 2012, 89 : 47 - 56
  • [3] Development and validation of a UHPLC-ESI-MS/MS method for the simultaneous quantification of mammal lysophosphatidylcholines and lysophosphatidylethanolamines in serum
    Suarez-Garcia, Susana
    Arola, Lluis
    Pascual-Serrano, Aida
    Arola-Arnal, Anna
    Aragones, Gerard
    Blade, Cinta
    Suarez, Manuel
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1055 : 86 - 97
  • [4] Total Analysis of the Major Secoiridoids in Extra Virgin Olive Oil: Validation of an UHPLC-ESI-MS/MS Method
    Lozano-Castellon, Julian
    Lopez-Yerena, Anallely
    Olmo-Cunillera, Alexandra
    Jauregui, Olga
    Perez, Maria
    Lamuela-Raventos, Rosa Ma
    Vallverdu-Queralt, Anna
    ANTIOXIDANTS, 2021, 10 (04)
  • [5] COMPARISON OF ELISA WITH UHPLC-ESI-MS/MS METHOD FOR THE DETERMINATION OF AFLATOXIN Mi IN MILK
    Ibrahimi, Arieta Camaj
    Arbneshi, Tahir
    Meyer, Karsten
    Berisha, Bajram
    Hajrulai-Musliu, Zehra
    Haziri, Arben
    Isa, Aferdita Camaj
    INTERNATIONAL JOURNAL OF ECOSYSTEMS AND ECOLOGY SCIENCE-IJEES, 2021, 11 (03): : 593 - 598
  • [6] Characterization of epimerization and composition of heparin and dalteparin using a UHPLC-ESI-MS/MS method
    Zhang, Tianji
    Liu, Xin
    Li, Hongmei
    Wang, Zhangjie
    Chi, Lianli
    Li, Jin-Ping
    Tan, Tianwei
    CARBOHYDRATE POLYMERS, 2019, 203 : 87 - 94
  • [7] A sensitive UHPLC-ESI-MS/MS method for the determination of tropane alkaloids in herbal teas and extracts
    Cirlini, Martina
    Cappucci, Valentina
    Galaverna, Gianni
    Dall'Asta, Chiara
    Bruni, Renato
    FOOD CONTROL, 2019, 105 : 285 - 291
  • [8] Simultaneous determination of eight components in Angelica sinensis based on UHPLC-ESI-MS/MS method for quality evaluation
    Gui, Qiaodi
    Zheng, Jie
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (02)
  • [9] The determination of 22 natural brassinosteroids in a minute sample of plant tissue by UHPLC-ESI-MS/MS
    Tarkowska, Danuse
    Novak, Ondrej
    Oklestkova, Jana
    Strnad, Miroslav
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (24) : 6799 - 6812
  • [10] UHPLC-ESI-MS/MS Quantitative Analyses of Multicomponent Hu Gan Tablets
    Liang, Jun
    Guo, Xin-Dong
    Han, Fang
    MOLECULES, 2019, 24 (23):