A Method of Damage Detection Efficiency Enhancement of PZT Sensor Networks under Influence of Environmental and Operational Conditions

被引:2
作者
Dziendzikowski, Michal [1 ]
Heesch, Mateusz [2 ]
Gorski, Jakub [2 ]
Kowalczyk, Kamil [1 ]
Dragan, Krzysztof [1 ]
Dworakowski, Ziemowit [2 ]
机构
[1] Aif Force Inst Technol, Airworthiness Div, Ul Ks Boleslawa 6, PL-01494 Warsaw, Poland
[2] AGH Univ Sci & Technol, Fac Mech Engn & Robot, Dept Robot & Mechatron, PL-30059 Krakow, Poland
关键词
structural health monitoring; damage detection capabilities enhancement; environmental and operational conditions compensation; PZT transducers applications; TEMPERATURE COMPENSATION METHOD; PERFORMANCE; WAVES; LOAD;
D O I
10.3390/s23010369
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two performance parameters are particularly important for the assessment of structural health monitoring (SHM) systems, i.e., their damage detection capabilities and risk of false positive indications due to varying environmental and operational conditions (EOCs). A reduced ratio of false-positive indications can be of significant importance for particular applications, for example, in aerospace, where the costs of unplanned maintenance procedures can be very high. In such cases, the reduction of the false calls ratio can be critical for the possibility of the practical application of the system, apart from damage detection efficiency and system costs. Among various sensor technologies, PZT networks are proven to be one of the most universal approaches to SHM, and they were successfully applied in different scenarios. Moreover, many EOCs which may have an impact on the risk of false positive indications have been identified. Over the years, different approaches to the influence of EOCs compensation have been proposed. Compensation methods can be tailored to the particular way in which a given measurement condition, for example, ambient temperature, alters signals acquired by the PZT network or can be formulated to be also applied in the more general case. In the paper, a method for enhancement of damage detection efficiency under influence of EOCs of general nature is proposed. The particular measurement condition affecting signals acquired by PZT sensors neither needs to be measured, which could be hard in some cases, but also nor even have to be identified. The efficiency of the proposed compensation algorithms is verified based on the example of experimental results obtained under varying temperatures.
引用
收藏
页数:18
相关论文
共 43 条
  • [11] EC Electronics, US
  • [12] Fraden J, 2010, HANDBOOK OF MODERN SENSORS: PHYSICS, DESIGNS, AND APPLICATIONS, FOURTH EDITION, P1, DOI 10.1007/978-1-4419-6466-3
  • [13] Giurgiutiu V, 2014, STRUCTURAL HEALTH MONITORING WITH PIEZOELECTRIC WAFER ACTIVE SENSORS, 2ND EDITION, P199, DOI 10.1016/B978-0-12-418691-0.00005-8
  • [14] Environmental and operational conditions effects on Lamb wave based structural health monitoring systems: A review
    Gorgin, Rahim
    Luo, Ying
    Wu, Zhanjun
    [J]. ULTRASONICS, 2020, 105
  • [15] Identification of damage in a suspension component using narrowband and broadband nonlinear signal processing techniques
    Haroon, Muhammad
    Adams, Douglas E.
    [J]. HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2007, 2007, 6532
  • [16] Heywang W, 2008, SPRINGER SER MATER S, V114, P1
  • [17] Damage detection sensitivity characterization of acousto-ultrasound-based structural health monitoring techniques
    Janapati, Vishnuvardhan
    Kopsaftopoulos, Fotis
    Li, Frank
    Lee, Sang Jun
    Chang, Fu-Kuo
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2016, 15 (02): : 143 - 161
  • [18] PZT based smart corrosion coupon using electromechanical impedance
    Li, Weijie
    Liu, Tiejun
    Zou, Dujian
    Wang, Jianjun
    Yi, Ting-Hua
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 129 : 455 - 469
  • [19] Non-destructive concrete strength evaluation using smart piezoelectric transducer-a comparative study
    Lim, Yee Yan
    Kwong, Kok Zee
    Liew, Willey Yun Hsien
    Soh, Chee Kiong
    [J]. SMART MATERIALS AND STRUCTURES, 2016, 25 (08)
  • [20] A methodology for structural health monitoring with diffuse ultrasonic waves in the presence of temperature variations
    Lu, YH
    Michaels, JE
    [J]. ULTRASONICS, 2005, 43 (09) : 717 - 731