An advanced LC-MS/MS protocol for simultaneous detection of pharmaceuticals and personal care products in the environment

被引:11
作者
Yao, Wenrui [1 ]
Ge, Jinfeng [1 ]
Hu, Qiaozhuan [1 ]
Ma, Jingying [1 ]
Yuan, Daohe
Fu, Xiaoli [1 ]
Qi, Yulin [1 ,2 ]
Volmer, Dietrich A. [3 ]
机构
[1] Tianjin Univ, Inst Surface Earth Syst Sci, Sch Earth Syst Sci, Tianjin, Peoples R China
[2] Tianjin Univ, Tianjin Bohai Rim Coastal Earth Crit Zone Natl Ob, Tianjin, Peoples R China
[3] Univ Berlin, Dept Chem, Berlin, Germany
基金
中国国家自然科学基金;
关键词
SOLID-PHASE EXTRACTION; WASTE-WATER; MASS-SPECTROMETRY; BOHAI SEA; PPCPS; ANTIBIOTICS; SURFACE; ONLINE; CHINA;
D O I
10.1002/rcm.9397
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The development of appropriate analytical screening techniques for pharmaceuticals and personal care products (PPCPs) is the basis for studying the distribution and environmental impact of emerging contaminants (ECs). Mass spectrometry-based screening methods vary with the complexity of the target compounds. It is challenging to balance both positive and negative ion quantification with a low detection limit. To establish a set of experimental methods including extraction, chromatography-separation and mass spectrometry screening is one of the most important topics in PPCP research. This paper describes a universal and efficient qualification and quantification protocol for the simultaneous detection of 34 PPCPs in different environmental samples in a single analytical data acquisition run. Methods Thirty-four representative PPCPs, which are widely distributed in the environment with high ecological toxicity and complex chemical structures, were selected as representative target ECs. The extraction of the target PPCPs was achieved using only one solid-phase extraction cartridge without the need to adjust the pH of samples. The enriched samples were detected by LC-MS/MS in both positive and negative ion modes simultaneously. The protocol was evaluated based on the accuracy, precision, detection limits and matrix effects. Results This method achieved simultaneous detection of PPCPs in both positive and negative ion modes, with a single analytical cycle of 12 min. The observed SPE recoveries were between 40% and 115%. The instrumental detection limits (IDL) varied from 0.01 to 1 pg, and the method detection limits (MDL) were between 0.002 and 3.323 ng/l in different matrices. Most of the PPCPs were subjected to matrix suppression below 30%. The method was successfully applied for quantitative analysis of the PPCPs in different environmental samples, including river samples, wastewater treatment plant (WWTP) samples and soil samples. Conclusions This protocol developed a rapid and efficient detection method to simultaneous qualitative and quantitative 34 representative PPCPs in the environment. The IDL ranged from 0.01 to 1 pg and the MDL ranged from 0.002 to 3.323 ng/l in different matrices. The detection limit was one order of magnitude lower compared to previous studies. The protocol also provided a wide application range for different environmental matrices, which permitted the migration and transformation of PPCPs to be explored.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Simultaneous assessment of endogenous thiol compounds by LC-MS/MS
    Sun, Yao
    Yao, Tong
    Guo, Xiucai
    Peng, Ying
    Zheng, Jiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1029 : 213 - 221
  • [22] Development of an LC-MS/MS peptide mapping protocol for the NISTmAb
    Trina Mouchahoir
    John E. Schiel
    Analytical and Bioanalytical Chemistry, 2018, 410 : 2111 - 2126
  • [23] Development of an LC-MS/MS peptide mapping protocol for the NISTmAb
    Mouchahoir, Trina
    Schiel, John E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (08) : 2111 - 2126
  • [24] Simultaneous stereoselective detection of chiral fungicides in soil by LC-MS/MS with fast sample preparation
    Chai, Tingting
    Jia, Qi
    Yang, Shuming
    Qiu, Jing
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (05) : 595 - 601
  • [25] Development of a solvent-free method for the simultaneous identification/quantification of drugs of abuse and their metabolites in environmental water by LC-MS/MS
    Martinez Bueno, M. J.
    Ucles, S.
    Hernando, M. D.
    Fernandez-Alba, A. R.
    TALANTA, 2011, 85 (01) : 157 - 166
  • [26] Determination of Pindone in Animal Products, Fishery Products, and Honey by LC-MS/MS
    Saito, Shizuka
    Sakai, Takatoshi
    Nemoto, Satoru
    Matsuda, Rieko
    FOOD HYGIENE AND SAFETY SCIENCE, 2011, 52 (05): : 294 - 298
  • [27] A SPE-LC-MS/MS METHOD FOR THE DETECTION OF LOW CONCENTRATIONS OF PHARMACEUTICALS IN INDUSTRIAL WASTE STREAMS
    Deegan, Ann-Marie
    Cullen, Mark
    Oelgemoeller, Michael
    Nolan, Kieran
    Tobin, John
    Morrissey, Anne
    ANALYTICAL LETTERS, 2011, 44 (17) : 2808 - 2820
  • [28] Determination of Diniconazole in Agricultural Products, Livestock and Marine Products by LC-MS/MS
    Asakura, Takayuki
    Kitamura, Mariko
    Seki, Wataru
    Iida, Tomonari
    Nakazat, Mitsuo
    Yasuda, Kazuo
    Nemoto, Satoru
    FOOD HYGIENE AND SAFETY SCIENCE, 2017, 58 (04): : 195 - 200
  • [29] Quantification of Pharmaceuticals and Personal Care Product Residues in Surface and Drinking Water Samples by SPE and LC-ESI-MS/MS
    Silveira, Maria Angelis K.
    Caldas, Sergiane S.
    Guilherme, Juliana R.
    Costa, Fabiane P.
    Guimaraes, Bruno de S.
    Cerqueira, Maristela B. R.
    Soares, Bruno M.
    Primel, Ednei G.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (09) : 1385 - 1395
  • [30] LABORATORY VALIDATION OF AN LC-MS/MS METHOD FOR SIMULTANEOUS DETERMINATION OF CARBAMATE RESIDUES IN VEGETABLES
    Hanh, Vu Thi
    Duong, Ngo Van
    ACTA SCIENTIARUM POLONORUM-TECHNOLOGIA ALIMENTARIA, 2023, 22 (04) : 385 - 394