Effect of ambient temperature, metabolic heat and clothing insulation on the required external active heating for the survival of humans exposed to sub-zero temperatures

被引:3
作者
Dupade, Vikrant [1 ]
Premachandran, B. [1 ]
Rengasamy, R. S. [2 ]
Talukdar, Prabal [1 ]
机构
[1] Indian Inst Technol Delhi, Dept Mech Engn, New Delhi 110016, India
[2] Indian Inst Technol Delhi, Dept Text & Fibre Engn, New Delhi, India
关键词
Active heating; clothing insulation; metabolic heat; cold climatic condition; PHASE-CHANGE MATERIALS; COLD; TEXTILES; MANAGEMENT; FABRICS;
D O I
10.1080/00405000.2022.2109108
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Active heating in extremely cold weather clothing would be useful to save the life of an injured or sick person due to low metabolic rate. A fully dressed thermal manikin is useful in evaluating the performance of the active heating ensemble. The thermal manikin tests are time-consuming and could be done only after making the complete ensemble. An experiment that is designed to evaluate the performance of an active heating fabric fixed to a set of layers of extreme cold climate clothing using a guarded hot plate instrument would save a lot of time as it skips the processes of garmenting and subsequent evaluation on the thermal manikin. In this work, a guarded hot plate placed inside a cold chamber is used to investigate the external heating required for the prolonged comfort of the wearer at various sub-zero ambient temperatures, clothing insulation and metabolic heat. A plain woven active heating fabric sandwiched between a knitted fabric and nonwoven of different insulation/thickness is used to perform experiments. The external heat required to keep the test plate (representing the human skin) at 307 +/- 1 K (34 +/- 1 degrees C) is measured at different experimental conditions. Further, a one-dimensional numerical model based on coupled conduction-radiation heat transfer with heat generation was developed and validated with experimental results. The experimental temperature profiles match well with the numerical temperature profiles at different locations, justifying the numerical methodology adopted in this work. This suggests that the developed numerical model would also be useful to estimate the required active heating as per the wearer's requirement and an available power source. Both the experimental and numerical results suggest that the external active heating required to maintain test plate (skin) temperatures within the human skin comfortable range is a function of ambient temperature, metabolic heat and clothing (nonwoven) insulation.
引用
收藏
页码:1125 / 1134
页数:10
相关论文
共 50 条
  • [1] Akbar A. R., 2016, American Journal of Polymer Science Engineering, V4, P133
  • [2] Flexible heating fabrics with temperature perception based on fine copper wire and fusible interlining fabrics
    Bai Yanyan
    Li Hongxia
    Gan Shijin
    Li Yafang
    Liu Hao
    Chen Li
    [J]. MEASUREMENT, 2018, 122 : 192 - 200
  • [3] Mid-infrared emissivity of nylon, cotton, acrylic, and polyester fabrics as a function of moisture content
    Belliveau, Raymond
    Dejong, Stephanie
    Boltin, Nicholas D.
    Lu, Zhenyu
    Cassidy, Brianna M.
    Morgan, Stephen L.
    Myrick, M. L.
    [J]. TEXTILE RESEARCH JOURNAL, 2020, 90 (13-14) : 1431 - 1445
  • [4] Biem J, 2003, CAN MED ASSOC J, V168, P305
  • [5] BUDD GM, 1989, SCAND J WORK ENV HEA, V15, P15
  • [6] Chambers P.A., 2006, Personal cooling or warming system using closed loop fluid flow U.S. Patent No, Patent No. [US7000682B2), 70006822]
  • [7] LOCAL HEATING SOURCE FOR SHALLOW-WATER DIVERS
    CHAN, CYL
    BURTON, DR
    [J]. JOURNAL OF POWER SOURCES, 1981, 6 (03) : 291 - 304
  • [8] Effects of local heating on thermal comfort of standing people in extremely cold environments
    Deng, Yue
    Cao, Bin
    Liu, Bin
    Zhu, Yingxin
    [J]. BUILDING AND ENVIRONMENT, 2020, 185
  • [9] The effect of direct and indirect hand heating on finger blood flow and dexterity during cold exposure
    Ducharme, MB
    Brajkovic, D
    Frim, J
    [J]. JOURNAL OF THERMAL BIOLOGY, 1999, 24 (5-6) : 391 - 396
  • [10] Estimation of Temperature-Dependent Effective Thermal Conductivity and Specific Heat of Thermally Bonded High Bulk Nonwoven Exposed to Sub-Zero Temperature
    Dupade, Vikrant
    Premachandran, B.
    Rengasamy, R. S.
    Talukdar, Prabal
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (06)