Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T

被引:0
作者
Vymazal, Josef [1 ]
Ryznarova, Zuzana [1 ]
Rulseh, Aaron M. [1 ]
机构
[1] Na Homolce Hosp, Dept Radiol, Roentgenova 2, Prague 15030, Czech Republic
关键词
Brain metastasis; Imaging sequences; Magnetic resonance imaging; Radiosurgery; ENHANCEMENT; TUMORS; DIMEGLUMINE; GADOBUTROL;
D O I
10.1186/s13244-024-01643-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Accurate detection of metastatic brain lesions (MBL) is critical due to advances in radiosurgery. We compared the results of three readers in detecting MBL using T1-weighted 2D spin echo (SE) and sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences with whole-brain coverage at both 1.5 T and 3 T. Methods Fifty-six patients evaluated for MBL were included and underwent a standard protocol (1.5 T, n = 37; 3 T, n = 19), including postcontrast T1-weighted SE and SPACE. The rating was performed by three raters in two sessions > six weeks apart. The true number of MBL was determined using all available imaging including follow-up. Intraclass correlations for intra-rater and inter-rater agreement were calculated. Signal intensity ratios (SIR; enhancing lesion, white matter) were determined on a subset of 46 MBL > 4 mm. A paired t-test was used to evaluate postcontrast sequence order and SIR. Reader accuracy was evaluated by the coefficient of determination. Results A total of 135 MBL were identified (mean/subject 2.41, SD 6.4). The intra-rater agreement was excellent for all 3 raters (ICC = 0.97-0.992), as was the inter-rater agreement (ICC = 0.995 SE, 0.99 SPACE). Subjective qualitative ratings were lower for SE images; however, signal intensity ratios were higher in SE sequences. Accuracy was high in all readers for both SE (R-2 0.95-0.96) and SPACE (R-2 0.91-0.96) sequences. Conclusions Although SE sequences are superior to gradient echo sequences in the detection of small MBL, they have long acquisition times and frequent artifacts. We show that T1-weighted SPACE is not inferior to standard thin-slice SE sequences in the detection of MBL at both imaging fields. Critical relevance statement Our results show the suitability of 3D T1-weighted turbo spin echo (TSE) sequences (SPACE, CUBE, VISTA) in the detection of brain metastases at both 1.5 T and 3 T.
引用
收藏
页数:8
相关论文
共 22 条
  • [11] THEORETICAL-ANALYSIS OF GADOPENTETATE DIMEGLUMINE ENHANCEMENT IN T1-WEIGHTED IMAGING OF THE BRAIN - COMPARISON OF 2-DIMENSIONAL SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO SEQUENCES
    MUGLER, JP
    BROOKEMAN, JR
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 761 - 769
  • [12] Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla
    Nöbauer-Huhmann, IM
    Ba-Ssalamah, A
    Mlynarik, V
    Barth, M
    Schöggl, A
    Heimberger, K
    Matula, C
    Fog, A
    Kaider, A
    Trattnig, S
    [J]. INVESTIGATIVE RADIOLOGY, 2002, 37 (03) : 114 - 119
  • [13] Detection of Small Metastatic Brain Tumors Comparison of 3D Contrast-Enhanced Whole-Brain Black-Blood Imaging and MP-RAGE Imaging
    Park, Jaeseok
    Kim, Jinna
    Yoo, Eunhye
    Lee, Hyunyeol
    Chang, Jong-Hee
    Kim, Eung Yeop
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 136 - 141
  • [14] A Comprehensive Review of MR Imaging Changes following Radiosurgery to 500 Brain Metastases
    Patel, T. R.
    McHugh, B. J.
    Bi, W. L.
    Minja, F. J.
    Knisely, J. P. S.
    Chiang, V. L.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1885 - 1892
  • [15] Pope Whitney B, 2018, Handb Clin Neurol, V149, P89, DOI 10.1016/B978-0-12-811161-1.00007-4
  • [16] Comparison between 1.5-and 3-T Magnetic Resonance Acquisitions for Direct Targeting Stereotactic Procedures for Deep Brain Stimulation: A Phantom Study
    Poulen, Gaetan
    Chan Seng, Emilie
    Menjot De Champfleur, Nicolas
    Cif, Laura
    Cyprien, Fabienne
    Perez, Jerome
    Coubes, Philippe
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2020, 98 (05) : 337 - 344
  • [17] R Core Team R Core Team, 2021, R: A Language and Environment for Statistical Computing
  • [18] Does Higher Gadolinium Concentration Play a Role in the Morphologic Assessment of Brain Tumors? Results of a Multicenter Intraindividual Crossover Comparison of Gadobutrol versus Gadobenate Dimeglumine (the MERIT Study)
    Seidl, Z.
    Vymazal, J.
    Mechl, M.
    Goyal, M.
    Herman, M.
    Colosimo, C.
    Pasowicz, M.
    Yeung, R.
    Paraniak-Gieszczyk, B.
    Yemen, B.
    Anzalone, N.
    Citterio, A.
    Schneider, G.
    Bastianello, S.
    Ruscalleda, J.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1050 - 1058
  • [19] Usefulness of double dose contrast-enhanced magnetic resonance imaging for clear delineation of gross tumor volume in stereotactic radiotherapy treatment planning of metastatic brain tumors: a dose comparison study
    Subedi, Kalloo Sharma
    Takahashi, Takeo
    Yamano, Takafumi
    Saitoh, Jun-ichi
    Nishimura, Keiichiro
    Suzuki, Yoshiyuki
    Ohno, Tatsuya
    Nakano, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2013, 54 (01) : 135 - 139
  • [20] The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis
    Suh, Chong Hyun
    Jung, Seung Chai
    Kim, Kyung Won
    Pyo, Junhee
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2016, 129 (02) : 363 - 371