Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T

被引:0
作者
Vymazal, Josef [1 ]
Ryznarova, Zuzana [1 ]
Rulseh, Aaron M. [1 ]
机构
[1] Na Homolce Hosp, Dept Radiol, Roentgenova 2, Prague 15030, Czech Republic
关键词
Brain metastasis; Imaging sequences; Magnetic resonance imaging; Radiosurgery; ENHANCEMENT; TUMORS; DIMEGLUMINE; GADOBUTROL;
D O I
10.1186/s13244-024-01643-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Accurate detection of metastatic brain lesions (MBL) is critical due to advances in radiosurgery. We compared the results of three readers in detecting MBL using T1-weighted 2D spin echo (SE) and sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences with whole-brain coverage at both 1.5 T and 3 T. Methods Fifty-six patients evaluated for MBL were included and underwent a standard protocol (1.5 T, n = 37; 3 T, n = 19), including postcontrast T1-weighted SE and SPACE. The rating was performed by three raters in two sessions > six weeks apart. The true number of MBL was determined using all available imaging including follow-up. Intraclass correlations for intra-rater and inter-rater agreement were calculated. Signal intensity ratios (SIR; enhancing lesion, white matter) were determined on a subset of 46 MBL > 4 mm. A paired t-test was used to evaluate postcontrast sequence order and SIR. Reader accuracy was evaluated by the coefficient of determination. Results A total of 135 MBL were identified (mean/subject 2.41, SD 6.4). The intra-rater agreement was excellent for all 3 raters (ICC = 0.97-0.992), as was the inter-rater agreement (ICC = 0.995 SE, 0.99 SPACE). Subjective qualitative ratings were lower for SE images; however, signal intensity ratios were higher in SE sequences. Accuracy was high in all readers for both SE (R-2 0.95-0.96) and SPACE (R-2 0.91-0.96) sequences. Conclusions Although SE sequences are superior to gradient echo sequences in the detection of small MBL, they have long acquisition times and frequent artifacts. We show that T1-weighted SPACE is not inferior to standard thin-slice SE sequences in the detection of MBL at both imaging fields. Critical relevance statement Our results show the suitability of 3D T1-weighted turbo spin echo (TSE) sequences (SPACE, CUBE, VISTA) in the detection of brain metastases at both 1.5 T and 3 T.
引用
收藏
页数:8
相关论文
共 22 条
  • [1] Detection of Cerebral Metastases on Magnetic Resonance Imaging: Intraindividual Comparison of Gadobutrol with Gadopentetate Dimeglumine
    Anzalone, Nicoletta
    Gerevini, Simonetta
    Scotti, Roberta
    Vezzulli, Paolo
    Picozzi, Pieru
    [J]. ACTA RADIOLOGICA, 2009, 50 (08) : 933 - 940
  • [2] Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    Busse, Reed F.
    Brau, Anja C. S.
    Vu, Anthony
    Michelich, Charles R.
    Bayram, Ersin
    Kijowski, Richard
    Reeder, Scott B.
    Rowley, Howard A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 640 - 649
  • [3] CHAPPELL PM, 1994, AM J NEURORADIOL, V15, P37
  • [4] Fink Kathleen R, 2013, Surg Neurol Int, V4, pS209, DOI 10.4103/2152-7806.111298
  • [5] Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance Imaging of brain metastasis at 3-T magnetic resonance imaging
    Furutani, Kaori
    Harada, Masafumi
    Mawlan, Mahmut
    Nishitani, Hiromu
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (02) : 313 - 319
  • [6] ZAP-X Gyroscopic Radiosurgery System: A Preliminary Analysis of Clinical Applications within a Retrospective Case Series
    Hendricks, Benjamin K.
    DiDomenico, Joseph D.
    Barani, Igor J.
    Barranco, F. David
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2022, 100 (02) : 99 - 107
  • [7] Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Ohnari, Norihiro
    Moriya, Junji
    Kamada, Koji
    Hanamiya, Mai
    Sato, Toru
    Kitajima, Mika
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (09) : 2345 - 2351
  • [8] Consensus recommendations for a standardized brain tumor imaging protocol for clinical trials in brain metastases
    Kaufmann, Timothy J.
    Smits, Marion
    Boxerman, Jerrold
    Huang, Raymond
    Barboriak, Daniel P.
    Weller, Michael
    Chung, Caroline
    Tsien, Christina
    Brown, Paul D.
    Shankar, Lalitha
    Galanis, Evanthia
    Gerstner, Elizabeth
    van den Bent, Martin J.
    Burns, Terry C.
    Pamey, Ian F.
    Dunn, Gavin
    Brastianos, Priscilla K.
    Lin, Nancy U.
    Wen, Patrick Y.
    Ellingson, Benjamin M.
    [J]. NEURO-ONCOLOGY, 2020, 22 (06) : 757 - 772
  • [9] Komada Tomohiro, 2008, Magn Reson Med Sci, V7, P13, DOI 10.2463/mrms.7.13
  • [10] Dedicated isotropic 3-D T1 SPACE sequence imaging for radiosurgery planning improves brain metastases detection and reduces the risk of intracranial relapse
    Kutuk, Tugce
    Abrams, Kevin J.
    Tom, Martin C.
    Rubens, Muni
    Appel, Haley
    Sidani, Charif
    Hall, Matthew D.
    Tolakanahalli, Ranjini
    Wieczorek, Jay J.
    Gutierrez, Alonso N.
    McDermott, Michael W.
    Ahluwalia, Manmeet S.
    Mehta, Minesh P.
    Kotecha, Rupesh
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 173 : 84 - 92