Experimental and numerical study on shear behaviour of concrete-filled double-skin steel tubular structures

被引:2
|
作者
Ding, Ran [1 ]
Bai, Hao-hao [2 ]
Sun, Yun-lun [3 ,4 ]
Chen, Yan [5 ]
Fan, Jian-sheng [6 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[4] CNNC Shandong Nucl Energy Co Ltd, Yantai 265100, Peoples R China
[5] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[6] Chinergy Co LTD, Beijing 100193, Peoples R China
关键词
Concrete-filled double-skin steel tubular; (CFDST) structures; Deep beam; Shear mechanism; Shear strength formula; TUBES; CHS;
D O I
10.1016/j.engstruct.2024.117587
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concrete-filled double-skin steel tubular (CFDST) structures show high strength, large stiffness and convenient construction, which has been adopted in engineering practice more and more widely. However, the nonlinear shear behaviour of CFDST is still lack of research when the shear span ratio is low. This study conducts shear tests on four CFDST deep beams with large diameter of 1500 mm as well as low shear span ratio of 0.33 and 0.83, based on the application of CFDST in a typical nuclear engineering. The failure modes, load-displacement relations, concrete cracks and strains on steel tubes are carefully analysed. Then a refined nonlinear finite element model is built and the shear mechanism of the CFDST is revealed. The shear contribution of various components is obtained including the outer and inner steel tubes, the in-filled concrete, the stiffeners. Parametric analysis is further conducted to find the influence of key design parameters including hollow ratio, material strength and thickness of steel plate. Finally, based on test results and finite element analysis, a shear capacity formula considering the superposition of concrete, steel tube and stiffeners is proposed. It is demonstrated that the CFDST beams show typical shear failure for shear span ratio of 0.33 while shear-flexure failure for shear span ratio of 0.83. The shear strength is high with satisfied ductility. The proposed formula gives accurate prediction which is verified by test results and finite element analysis.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Seismic behaviors of embedded double-skin concrete-filled steel tubular column to foundation connection
    NCREE, Taipei 106, Taiwan
    不详
    Hunan Daxue Xuebao, 2006, SUPPL. (52-62):
  • [32] Flexural behavior of circular rubberized concrete-filled double-skin steel tubular beams: Experiments
    Akter, Mumtahina
    Sulong, N. H. Ramli
    Ayough, Pouria
    Tafsirojjaman, T.
    Fawzia, Sabrina
    ENGINEERING STRUCTURES, 2024, 306
  • [33] Numerical investigation on the response of circular double-skin concrete-filled steel tubular slender columns subjected to biaxial bending
    Abu-Shamah, Awni
    Allouzi, Rabab
    STEEL AND COMPOSITE STRUCTURES, 2020, 37 (05): : 533 - 549
  • [34] Numerical analysis of circular double-skin concrete-filled stainless steel tubular short columns under axial loading
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    STRUCTURES, 2020, 24 : 754 - 765
  • [35] Study on the behavior of concrete-filled square double-skin steel tubular stub columns under axial loading
    Ding, Fa-xing
    Wang, Wen-jun
    Lu, De-ren
    Liu, Xue-mei
    STRUCTURES, 2020, 23 : 665 - 676
  • [36] Experimental study on Tapered Concrete-Filled Double Skin Steel Tubular columns under torsion
    Deng, Ran
    Zhou, Xu-Hong
    Wang, Yu-Hang
    Bai, Jiu-Lin
    Deng, Xiao-Wei
    THIN-WALLED STRUCTURES, 2022, 177
  • [37] Numerical analysis of square concrete-filled double skin steel tubular columns with rubberized concrete
    Ayough, Pouria
    Ibrahim, Zainah
    Sulong, N. H. Ramli
    Hsiao, Po-Chien
    Elchalakani, Mohamed
    STRUCTURES, 2021, 32 : 1026 - 1047
  • [38] Compressive behaviour of tapered concrete-filled double skin steel tubular stub columns
    Deng, Ran
    Zhou, Xu-Hong
    Deng, Xiao-Wei
    Ke, Ke
    Bai, Jiu-Lin
    Wang, Yu-Hang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184
  • [39] Experimental study on torsional behavior of tapered high strength thin-walled concrete-filled double-skin steel tubular columns
    Li, Bo -Fan
    Wang, Xian-Tie
    Lv, Bao-Hua
    Yan, Xi-Feng
    Yan, Chen-Zhuang
    STRUCTURES, 2023, 55 : 1823 - 1838
  • [40] Experimental behaviour of concrete-filled steel tubular members under lateral shear loads
    Ye, Yong
    Han, Lin-Hai
    Tao, Zhong
    Guo, Shu-Li
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 226 - 237