Experimental and numerical study on shear behaviour of concrete-filled double-skin steel tubular structures

被引:2
|
作者
Ding, Ran [1 ]
Bai, Hao-hao [2 ]
Sun, Yun-lun [3 ,4 ]
Chen, Yan [5 ]
Fan, Jian-sheng [6 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[4] CNNC Shandong Nucl Energy Co Ltd, Yantai 265100, Peoples R China
[5] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[6] Chinergy Co LTD, Beijing 100193, Peoples R China
关键词
Concrete-filled double-skin steel tubular; (CFDST) structures; Deep beam; Shear mechanism; Shear strength formula; TUBES; CHS;
D O I
10.1016/j.engstruct.2024.117587
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concrete-filled double-skin steel tubular (CFDST) structures show high strength, large stiffness and convenient construction, which has been adopted in engineering practice more and more widely. However, the nonlinear shear behaviour of CFDST is still lack of research when the shear span ratio is low. This study conducts shear tests on four CFDST deep beams with large diameter of 1500 mm as well as low shear span ratio of 0.33 and 0.83, based on the application of CFDST in a typical nuclear engineering. The failure modes, load-displacement relations, concrete cracks and strains on steel tubes are carefully analysed. Then a refined nonlinear finite element model is built and the shear mechanism of the CFDST is revealed. The shear contribution of various components is obtained including the outer and inner steel tubes, the in-filled concrete, the stiffeners. Parametric analysis is further conducted to find the influence of key design parameters including hollow ratio, material strength and thickness of steel plate. Finally, based on test results and finite element analysis, a shear capacity formula considering the superposition of concrete, steel tube and stiffeners is proposed. It is demonstrated that the CFDST beams show typical shear failure for shear span ratio of 0.33 while shear-flexure failure for shear span ratio of 0.83. The shear strength is high with satisfied ductility. The proposed formula gives accurate prediction which is verified by test results and finite element analysis.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] NUMERICAL ANALYSIS ON POST-FIRE CYCLIC BEHAVIOUR OF CONCRETE-FILLED DOUBLE-SKIN STEEL TUBE
    Li, Wei
    Chen, Bing
    Wang, Tao
    Zhou, Kan
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1581 - 1587
  • [22] Experimental Study of Concrete-Filled Double-Skin Steel Tubular Beams with RHS Inner and Outer Subjected to Pure Bending
    Huang, Hong
    Yang, Jian
    Xie, Li
    Zhang, Ange
    INNOVATION AND SUSTAINABILITY OF MODERN RAILWAY, 2012, : 187 - 192
  • [23] Numerical analysis of rectangular double-skin concrete-filled steel tubular slender columns incorporating interaction buckling
    Rizwan, Muhammad
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    ENGINEERING STRUCTURES, 2021, 245
  • [24] Numerical analysis of square concrete-filled double-skin tubular columns with outer stainless-steel tube
    Tuan Trung Le
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Phat Huynh
    Ngoc San Ha
    STRUCTURAL CONCRETE, 2022, 23 (05) : 2968 - 2985
  • [25] Study on the fire performance of concrete-filled double-skin tubular columns with external stainless steel tubes
    Li J.-Q.
    Wang R.
    Zhao H.
    Wang H.-W.
    Gongcheng Lixue/Engineering Mechanics, 2020, 37 (10): : 125 - 133
  • [26] Experimental study on square concrete-filled double skin steel tubular short columns
    Guo, Zhan
    Chen, Yu
    Wang, Yao
    Jiang, Minyang
    THIN-WALLED STRUCTURES, 2020, 156 (156)
  • [27] Experimental study on concrete-filled double-skin circular steel tubes under combined loadings
    School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang
    330013, China
    不详
    330013, China
    Jianzhu Jiegou Xuebao, 9 (53-59):
  • [28] Experimental and Numerical Study of the Concrete-Filled Double-Skin Columns With Stainless Steel Outer Tubes Subjected to Cyclic Loading
    Albozagre, Haitham
    Naghipour, Morteza
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2025, 34 (05):
  • [29] Seismic behavior of stiffened concrete-filled double-skin tubular columns
    Shekastehband, B.
    Mohammadbagheri, S.
    Taromi, A.
    STEEL AND COMPOSITE STRUCTURES, 2018, 27 (05): : 577 - 598
  • [30] An experimental behaviour of concrete-filled steel tubular columns
    Zeghiche, J
    Chaoui, K
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (01) : 53 - 66