Experimental and numerical study on shear behaviour of concrete-filled double-skin steel tubular structures

被引:2
|
作者
Ding, Ran [1 ]
Bai, Hao-hao [2 ]
Sun, Yun-lun [3 ,4 ]
Chen, Yan [5 ]
Fan, Jian-sheng [6 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[4] CNNC Shandong Nucl Energy Co Ltd, Yantai 265100, Peoples R China
[5] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[6] Chinergy Co LTD, Beijing 100193, Peoples R China
关键词
Concrete-filled double-skin steel tubular; (CFDST) structures; Deep beam; Shear mechanism; Shear strength formula; TUBES; CHS;
D O I
10.1016/j.engstruct.2024.117587
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concrete-filled double-skin steel tubular (CFDST) structures show high strength, large stiffness and convenient construction, which has been adopted in engineering practice more and more widely. However, the nonlinear shear behaviour of CFDST is still lack of research when the shear span ratio is low. This study conducts shear tests on four CFDST deep beams with large diameter of 1500 mm as well as low shear span ratio of 0.33 and 0.83, based on the application of CFDST in a typical nuclear engineering. The failure modes, load-displacement relations, concrete cracks and strains on steel tubes are carefully analysed. Then a refined nonlinear finite element model is built and the shear mechanism of the CFDST is revealed. The shear contribution of various components is obtained including the outer and inner steel tubes, the in-filled concrete, the stiffeners. Parametric analysis is further conducted to find the influence of key design parameters including hollow ratio, material strength and thickness of steel plate. Finally, based on test results and finite element analysis, a shear capacity formula considering the superposition of concrete, steel tube and stiffeners is proposed. It is demonstrated that the CFDST beams show typical shear failure for shear span ratio of 0.33 while shear-flexure failure for shear span ratio of 0.83. The shear strength is high with satisfied ductility. The proposed formula gives accurate prediction which is verified by test results and finite element analysis.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] Numerical study of circular double-skin concrete-filled aluminum tubular stub columns
    Patel, Vipulkumar Ishvarbhai
    Qing Quan Liang
    Hadi, Muhammad N. S.
    ENGINEERING STRUCTURES, 2019, 197
  • [12] Experimental investigation of concrete-filled double-skin stainless steel tubular beam-columns
    Zhou, Feng
    Li, Yingfei
    Dong, Baiping
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [13] Torsional behaviour of tapered concrete-filled double-skin steel tubular columns with large hollow ratios
    Deng, Ran
    Zhou, Xu-Hong
    Wen, Hao
    Li, Rong-Fu
    Ji, Wei-Dong
    Wang, Yu-Hang
    Ren, Wei
    THIN-WALLED STRUCTURES, 2023, 183
  • [14] Numerical Modeling of Concrete-Filled Double-Skin Steel Square Tubular Columns under Blast Loading
    Zhang, Fangrui
    Wu, Chengqing
    Zhao, Xiao-Ling
    Li, Zhong-Xian
    Heidarpour, Amin
    Wang, Hongwei
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (05)
  • [15] Experimental behaviour of concrete-filled double-skin corrugated steel tubes under eccentric compression
    Lu, Bo
    Yang, Hua
    Fang, Yong
    ENGINEERING STRUCTURES, 2025, 327
  • [16] Experimental and numerical study on hysteretic behaviour of concrete-filled double tubular columns
    Wang W.
    Chen Y.
    Ji S.
    Shi Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (01): : 128 - 138
  • [17] Numerical simulation of high strength circular double-skin concrete-filled steel tubular slender columns
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2018, 168 : 205 - 217
  • [18] Concrete-filled double-skin tubular columns under fire
    Yang, Y. F.
    Han, L. -H.
    MAGAZINE OF CONCRETE RESEARCH, 2008, 60 (03) : 211 - 222
  • [19] Investigation of Concrete-Filled Double-Skin Steel Tubular Columns with Ultrahigh-Strength Steel
    Hsiao, Po-Chien
    Hayashi, K. Kazuhiro
    Nishi, Ryousuke
    Lin, Xu-Chuan
    Nakashima, Masayoshi
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (07)
  • [20] Fire resistance of restrained circular concrete-filled double-skin steel tubular columns
    Zheng, Yong-Qian
    Liang, Wang-Geng
    Zhang, Xue-Li
    MAGAZINE OF CONCRETE RESEARCH, 2022, 74 (11) : 557 - 571