Dose accuracy of the follitropin alfa pen injector 2.0, the follitropin alfa:lutropin alfa 2:1 combination pen injector 2.0 and the choriogonadotropin alfa pen injector 1.0 used for fertility treatment

被引:2
作者
Cottell, Evelyn [1 ]
Michalet, Damien [2 ]
Lispi, Monica [1 ,3 ]
Araujo, Thiago Dantas [2 ]
Gleixner, Ralf [2 ]
Longobardi, Salvatore [1 ,4 ]
D'Hooghe, Thomas [1 ,5 ,6 ,7 ]
机构
[1] Merck Healthcare KGaA, Darmstadt, Germany
[2] Ares Trading SA Eysins Affiliate Merck KGaA, Eysins, Switzerland
[3] Univ Modena & Reggio Emilia, Sch Clin & Expt Med, Unit Endocrinol, Modena, MO, Italy
[4] Merck Serono SpA, Global Clin Dev, Rome, Italy
[5] Katholieke Univ Leuven, Dept Dev & Regenerat, Lab Endometrium Endometriosis & Reprod Med, Leuven, Belgium
[6] Yale Univ, Med Sch, Dept Obstet Gynecol & Reprod Sci, New Haven, CT USA
[7] Merck KGaA, Frankfurter Str 250, D-64293 Darmstadt, Germany
关键词
Dose accuracy; pen injector; follitropin alfa; choriogonadotropin alfa; follitropin alfa/lutropin-alfa; PATIENT;
D O I
10.1080/17425247.2024.2311127
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
BackgroundThis study aimed to confirm that the incremental dose/clicks system dispenses accurate doses for the Merck family of fertility pen injectors. Research design and methodsSet doses (Vset) for three dose dial settings (minimum dose [Vmin], midpoint dose [Vmid] and maximum dose [Vmax] for the follitropin alfa, choriogonadotropin alfa [D2 classification: single use/variable dose], and follitropin alfa:lutropin-alfa 2:1 combination pen injectors) or a single Vset for the choriogonadotropin alfa (D1 classification: single use/single dose) were assessed. Last dose administered by the multi-dose device was assessed for the 900 IU, 450 IU, 300 IU and 150 IU follitropin alfa, and the 900:450 IU, 450:225 IU and 300:150 IU follitropin alfa:lutropin-alfa 2:1 combination pen presentations. ResultsDose accuracy tests for Vmin, Vmid and Vmax for the follitropin alfa and the follitropin alfa:lutropin-alfa 2:1 combination pen injectors, and last dose administered, were within acceptable limits according to ISO 11,608-1:2012/2014. Dose accuracy tests for the single use/single dose device classification and the single use/variable dose device classification of the choriogonadotropin alfa pen injector were also within the acceptable limits, according to ISO 11608-1:2000/2014. ConclusionsThe Merck family of fertility pen injectors functions reliably and the incremental dose/clicks system dispenses accurate doses.
引用
收藏
页码:337 / 346
页数:10
相关论文
共 19 条
[1]   A redesigned follitropin alfa pen injector for infertility: results of a market research study [J].
Abbotts, Carole ;
Salgado-Braga, Cristiana ;
Audibert-Gros, Celine .
PATIENT PREFERENCE AND ADHERENCE, 2011, 5 :315-331
[2]  
[Anonymous], Highlights of prescribing information - Victoza
[3]   A comparative, observational study evaluating dosing characteristics and ovarian response using the recombinant human follicle-stimulating hormone pen injector with small-dose dial in assisted reproductive technologies treatment in Asia: IMPROVE study [J].
Choi, Bum Chae ;
Zhou, Canquan ;
Ye, Hong ;
Sun, Yun ;
Zhong, Ying ;
Gong, Fei ;
Sini, Ivan ;
Abramova, Nadezda ;
Longobardi, Salvatore ;
Hickey, Miranda ;
D'Hooghe, Thomas .
REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2022, 20 (01)
[4]   The redesigned follitropin α pen injector for infertility treatment [J].
Christen, Michel ;
Schertz, Joan C. ;
Arriagada, Pablo ;
Keitel, Joachim ;
Mueller, Heiko .
EXPERT OPINION ON DRUG DELIVERY, 2011, 8 (06) :833-839
[5]   Satisfaction and usability of the recombinant chorionic gonadotropin prefilled pen: a survey in Italy [J].
Dallagiovanna, Chiara ;
Mensi, Laura ;
Di Gesaro, Luca ;
La Vecchia, Irene ;
Reschini, Marco .
DRUGS IN CONTEXT, 2022, 11
[6]  
EMA, 2023, NETHERLANDS EUROPEAN
[7]  
EMA, 2021, PERGOVERIS SUMMARY P
[8]  
EMA, 2021, OVITRELLE SUMMARY PR
[9]  
FDA, 2020, TECHNICAL CONSIDERAT
[10]  
ISO, 116081 ISO