An electrochemically cleanable pH electrode based on an electrodeposited iridium oxide-ruthenium oxide-titanium composite

被引:0
作者
Hu, Guangxing [1 ,2 ]
Diao, Yongxing [1 ,2 ]
Cui, Shuang [1 ,2 ]
Wang, Hongda [1 ,2 ,3 ]
Shi, Yan [1 ]
Li, Zhuang [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Qingdao Natl Lab Marine Sci & Technol, Qingdao 266200, Peoples R China
基金
中国国家自然科学基金;
关键词
WATER; SURFACE; OXYGEN; EVOLUTION;
D O I
10.1039/d3an01978k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biological contamination is an important issue in environmental pH detection, and our prepared electrochemically cleanable electrode may be an effective solution. By electrodepositing an iridium oxide-ruthenium oxide composite on a titanium sheet substrate, the electrode shows a sensitivity of 59.4 mV per pH in the pH range of 2-12 with high reproducibility, low hysteresis, high selectivity and high stability. It is worth mentioning that the electrode was proved to be electrochemically cleanable from biological contamination. When the cleaning time was 30 minutes, the electrode sensitivity rose from 50 to 58 mV per pH. Furthermore, the pH sensor, assembled from the prepared iridium-ruthenium oxide electrode and a home-made Ag/AgCl electrode, has similar electrode properties to those of commercial glass electrodes, but is also mechanically strong and electrochemically cleanable, which is promising for long-term deployment in natural environments. Biological contamination is an important issue in environmental pH detection, and our prepared electrochemically cleanable electrode may be an effective solution.
引用
收藏
页码:1327 / 1336
页数:10
相关论文
共 52 条
[21]   Low-Cost Flexible Glass-Based pH Sensor via Cold Atmospheric Plasma Deposition [J].
Kasi, Venkat ;
Sedaghat, Sotoudeh ;
Alcaraz, Alejandro M. ;
Maruthamuthu, Murali Kannan ;
Heredia-Rivera, Ulisses ;
Nejati, Sina ;
Nguyen, Juliane ;
Rahimi, Rahim .
ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (07) :9697-9710
[22]   Review on state-of-the-art in polymer based pH sensors [J].
Korostynska, Olga ;
Arshak, Khalil ;
Gill, Edric ;
Arshak, Arousian .
SENSORS, 2007, 7 (12) :3027-3042
[23]   Reviews the research on some dimensionally stable anodes (DSA) based on titanium [J].
Krstic, Vesna ;
Pesovski, Branka .
HYDROMETALLURGY, 2019, 185 :71-75
[24]   Assessing the Effect of Changing Ambient Air Temperature on Water Temperature and Quality in Drinking Water Distribution Systems [J].
Lai, Yuchuan ;
Dzombak, David A. .
WATER, 2021, 13 (14)
[25]   Inactivation of Microcystis aeruginosa by continuous electrochemical cycling process in tube using Ti/RuO2 electrodes [J].
Liang, WY ;
Qu, JH ;
Chen, LB ;
Liu, HJ ;
Lei, PJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (12) :4633-4639
[26]   Recent development and applications of optical and fiber-optic pH sensors [J].
Lin, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (09) :541-552
[27]   A titanium nitride nanotube array for potentiometric sensing of pH [J].
Liu, Mengyang ;
Ma, Yanling ;
Su, Lei ;
Chou, Kuo-Chih ;
Hou, Xinmei .
ANALYST, 2016, 141 (05) :1693-1699
[28]   Performance of IrOx pH Sensor Prepared by Electrochemical and Thermal Oxidation [J].
Liu, Xinyu ;
Pei, Yunxia ;
Wang, Yuanxia ;
Liu, Xiangju ;
Chen, Xuwei ;
Sun, Congtao ;
Liu, Nazhen .
IEEE SENSORS JOURNAL, 2022, 22 (13) :12560-12569
[29]   Anodically electrodeposited iridium oxide films microelectrodes for neural microstimulation and recording [J].
Lu, Yi ;
Wang, Tanyuan ;
Cai, Zhengxu ;
Cao, Yuliang ;
Yang, Hanxi ;
Duan, Yanwen Y. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01) :334-339
[30]   Response time of ion-selective electrodes -: Current usage versus IUPAC recommendations [J].
Maccà, C .
ANALYTICA CHIMICA ACTA, 2004, 512 (02) :183-190