masonry walls; strengthening; seismic performance; polyurethane; digital image correlation (DIC) technique; FAILURE MECHANISMS; SEISMIC BEHAVIOR; CYCLIC BEHAVIOR;
D O I
10.3390/buildings13102470
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to investigate the feasibility and effectiveness of spray-on polyurethane coating as a seismic strengthening method for rural masonry buildings. Three masonry wall specimens were tested under cyclic lateral loading, including a control specimen, a single-side strengthened specimen, and a double-side strengthened specimen. Digital image correlation (DIC) techniques were used to evaluate full-field strain, crack width, and failure progression in a non-contact manner. The seismic performances were compared in terms of failure mode, hysteretic behavior, skeleton curve, deformation performance, energy dissipation capacity, and stiffness degradation. Results indicated that a spray-on polyurethane coating effectively delayed the onset and progression of cracks, postponing the peak load and slowing strength and stiffness degradation. Compared to the unstrengthened specimen, the bearing capacity, ultimate displacement, and cumulative energy dissipation of the single-side strengthened specimen increased by 20%, 60%, and 514%, respectively. Compared to the single-side strengthened specimen, the double-side strengthened specimen BW-D exhibited improved integrity, deformation capacity, and energy dissipation capacity. Its ultimate displacement and cumulative energy dissipation increased by 28% and 10%, respectively.
引用
收藏
页数:15
相关论文
共 36 条
  • [1] Pseudo-static cyclic loading comparison of reinforced masonry walls strengthened with FRCM or NSM FRP
    Al-Jaberi, Zuhair
    Myers, John J.
    EIGawady, Mohamed A.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2018, 167 : 482 - 495
  • [2] SEISMIC BEHAVIOR OF UNREINFORCED AND CONFINED BRICK MASONRY WALLS BEFORE AND AFTER FERROCEMENT OVERLAY RETROFITTING
    Ashraf, Mohammad
    Khan, Akhtar Naeem
    Naseer, Amjad
    Ali, Qaisar
    Alam, Bashir
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2012, 6 (06) : 665 - 688
  • [3] Damage and performance evaluation of masonry buildings constructed in 1970s during the 2019 Albania earthquakes
    Bilgin, Huseyin
    Shkodrani, Neritan
    Hysenlliu, Marjo
    Ozmen, Hayri Baytan
    Isik, Ercan
    Harirchian, Ehsan
    [J]. ENGINEERING FAILURE ANALYSIS, 2022, 131
  • [4] Repair of Block Masonry Panels with CFRP Sheets
    Corradi, Marco
    Castori, Giulio
    Sisti, Romina
    Borri, Antonio
    Pesce, Giovanni Luca
    [J]. MATERIALS, 2019, 12 (15)
  • [5] Failure mechanisms of polymer-reinforced concrete masonry walls subjected to blast
    Davidson, JS
    Fisher, JW
    Hammons, MI
    Porter, JR
    Dinan, RJ
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2005, 131 (08): : 1194 - 1205
  • [6] Explosive testing of polymer retrofit masonry walls
    Davidson, JS
    Porter, JR
    Dinan, RJ
    Hammons, MI
    Connell, JD
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2004, 18 (02) : 100 - 106
  • [7] In-plane shear behavior of masonry panels strengthened with ultra-high ductile concrete (UHDC)
    Dong, Fangyuan
    Wang, Hanpeng
    Jiang, Fangming
    Xing, Qiong
    Yu, Jiangtao
    [J]. ENGINEERING STRUCTURES, 2022, 252
  • [8] In-plane seismic behavior of NSM strengthened adobe walls: Experimental evaluation of different reinforcements
    Eslami, Abolfazl
    Zahedi, Ali
    Banadaki, Hosein Mirabi
    [J]. ENGINEERING STRUCTURES, 2021, 246
  • [9] Cyclic shear-compression testing of brick masonry walls repaired and retrofitted with basalt textile reinforced mortar
    Garcia-Ramonda, Larisa
    Pela, Luca
    Roca, Pere
    Camata, Guido
    [J]. COMPOSITE STRUCTURES, 2022, 283
  • [10] In-plane shear behaviour by diagonal compression testing of brick masonry walls strengthened with basalt and steel textile reinforced mortars
    Garcia-Ramonda, Larisa
    Pela, Luca
    Roca, Pere
    Camata, Guido
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2020, 240 (240)