Non-equilibrium CFD simulation of the wet-to-dry expansion of the siloxane MM in a converging-diverging nozzle

被引:4
作者
Ogrodniczak, Pawel [1 ]
White, Martin T. [1 ,2 ]
机构
[1] City Univ London, Energy Sustainabil & Net zero Res Ctr ESaAN, Sch Sci & Technol, Northampton Sq, London EC1V 0HB, England
[2] Univ Sussex, Thermo Fluid Mech Res Ctr, Sch Engn & Informat, Brighton BN1 9RH, England
关键词
Two-phase expansion; Wet-to-dry cycle; Flash boiling; Organic Rankine cycle; Non-equilibrium; FLASH CYCLE SYSTEM; EQUATION-OF-STATE; RELAXATION MODEL; CRITICAL FLOW; 2-PHASE; PERFORMANCE; HEAT; TURBINE; DESIGN;
D O I
10.1016/j.applthermaleng.2023.121158
中图分类号
O414.1 [热力学];
学科分类号
摘要
Wet-to-dry organic Rankine cycles could generate 30% higher power outputs in the temperature range of 150 to 250 degrees C compared to existing single-phase cycles. Since the expansion is only partially wet, turboexpanders could potentially be applied provided that the wet portion of the expansion is confined to the stator to avoid erosion in the rotor. To assess the feasibility of achieving complete evaporation in the stator, two-dimensional non-equilibrium numerical simulations of the wet-to-dry expansion of siloxane MM in a covering-diverging nozzle are performed for the first time. The simulation setup is first validated against published experimental data, and a sensitivity study is conducted concerning the selected interphase models. The model is then applied to simulate expansions from inlet pressures ranging from 478 to 1250 kPa and vapour qualities from 0.1 to 0.5. Moreover, the droplet number density was varied between 1010 and 1014. The results show that the evaporation rate, the extent of non-equilibrium effects and the flow's spatial uniformity are predominantly dependent on the droplet size. Expansions beginning with droplets smaller than 20 & mu;m resulted in complete mixture evaporation and negligible non-equilibrium effects in almost all investigated cases. For larger droplets, ranging from 40 to 100 & mu;m, full evaporation could only be achieved for inlet pressures above 750 kPa and inlet qualities above 0.3, whereas for lower pressures, the outlet vapour quality varied between 80 and 90%. For droplets larger than 200 & mu;m, there is a significant delay in evaporation resulting in outlet quality typically between 40 and 70%. Larger droplet flows are characterised by substantial velocity slip, temperature difference, phase separation and lateral velocity variations. Having said this, droplet breakup analysis indicates that droplets larger than 100 & mu;m are likely to undergo breakup, which could enhance the evaporation rate; however, this requires further investigation. In conclusion, high inlet pressures and high inlet qualities are preferred from the perspective of ensuring dry-vapour conditions at the nozzle outlet.
引用
收藏
页数:20
相关论文
共 72 条
[1]  
Abuaf N., 1981, STUDY NONEQUILIBRIUM, V1
[2]   Waste heat mapping: A UK study [J].
Albert, Max D. A. ;
Bennett, Katherine O. ;
Adams, Charlotte A. ;
Gluyas, Jon G. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 160
[3]  
[Anonymous], 2004, 3 INT S 2 PHAS FLOW
[4]  
ANSYS Inc, CFX-Solver Modelling Guide
[5]  
ANSYS Inc, CFX-Solver Theory Guide
[6]  
ANSYS Inc, ANSYS CFX
[7]  
Brodkey S, 1967, PHENOMENA FLUID MOTI
[8]   A flexible and multi-functional organic Rankine cycle system: Preliminary experimental study and advanced exergy analysis [J].
Chen, Jianyong ;
Zheng, Xiaosheng ;
Guo, Guiqi ;
Luo, Xianglong ;
Chen, Ying ;
Yang, Zhi .
ENERGY CONVERSION AND MANAGEMENT, 2019, 187 :339-355
[9]   Experimental performance of a rotating two-phase reaction turbine [J].
Date, Abhijit ;
Vahaji, Sara ;
Andrews, John ;
Akbarzadeh, Aliakbar .
APPLIED THERMAL ENGINEERING, 2015, 76 :475-483
[10]   Performance of a rotating two-phase turbine for combined power generation and desalination [J].
Date, Abhijit ;
Khaghani, Anna ;
Andrews, John ;
Akbarzadeh, Aliakbar .
APPLIED THERMAL ENGINEERING, 2015, 76 :9-17