Universal Synthetic Aperture Sequence for Anatomic, Functional, and Super Resolution Imaging

被引:8
作者
Jensen, Jorgen Arendt [1 ]
Tomov, Borislav Gueorguiev [1 ]
Haslund, Lars Emil [1 ]
Panduro, Nathalie Sarup [2 ]
Sorensen, Charlotte Mehlin [2 ]
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[2] Univ Copenhagen, Dept Biomed Sci, DK-2200 Copenhagen, Denmark
基金
欧洲研究理事会;
关键词
Fast imaging; flow imaging; medical ultrasound; synthetic aperture (SA); PART II; ULTRASOUND; MOTION; PERFORMANCE; ELASTICITY; DOPPLER; DESIGN; PHASE;
D O I
10.1109/TUFFC.2023.3280803
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Synthetic aperture (SA) can be used for both anatomic and functional imaging, where tissue motion and blood velocity are revealed. Often, sequences optimized for anatomic B-mode imaging are different from functional sequences, as the best distribution and number of emissions are different. B-mode sequences demand many emissions for a high contrast, whereas flow sequences demand short sequences for high correlations yielding accurate velocity estimates. This article hypothesizes that a single, universal sequence can be developed for linear array SA imaging. This sequence yields high-quality linear and nonlinear B-mode images as well as accurate motion and flow estimates for high and low blood velocities and super-resolution images. Interleaved sequences with positive and negative pulse emissions for the same spherical virtual source were used to enable flow estimation for high velocities and make continuous long acquisitions for low-velocity estimation. An optimized pulse inversion (PI) sequence with 2 x 12 virtual sources was implemented for four different linear array probes connected to either a Verasonics Vantage 256 scanner or the SARUS experimental scanner. The virtual sources were evenly distributed over the whole aperture and permuted in emission order for making flow estimation possible using 4, 8, or 12 virtual sources. The frame rate was 208 Hz for fully independent images for a pulse repetition frequency of 5 kHz, and recursive imaging yielded 5000 images per second. Data were acquired from a phantom mimicking the carotid artery with pulsating flow and the kidney of a Sprague-Dawley rat. Examples include anatomic high contrast B-mode, non-linear B-mode, tissue motion, power Doppler, color flow mapping (CFM), vector velocity imaging, and super-resolution imaging (SRI) derived from the same dataset and demonstrate that all imaging modes can be shown retrospectively and quantitative data derived from it.
引用
收藏
页码:708 / 720
页数:13
相关论文
共 62 条
  • [1] [Anonymous], 2005, IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
  • [2] A New Ultrasonic Synthetic Aperture Tissue Harmonic Imaging System
    Bae, Moo-Ho
    Lee, Han-Woo
    Park, Sung Bae
    Yoon, Ra-Young
    Jeong, Min Hye
    Kim, Deok Gon
    Jeong, Mok-Kun
    Kim, Yung-Gil
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1258 - +
  • [3] Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    Bercoff, J
    Tanter, M
    Fink, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) : 396 - 409
  • [4] Brock-Fischer G. A., 1996, U.S. Patent, Patent No. 5577505
  • [5] EXPERIMENTAL 2 MHZ SYNTHETIC APERTURE SONAR SYSTEM INTENDED FOR MEDICAL USE
    BURCKHARDT, CB
    GRANDCHAMP, PA
    HOFFMANN, H
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1974, SU21 (01): : 1 - 6
  • [6] Nonlinear imaging
    Burns, PN
    Simpson, DH
    Averkiou, MA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 : S19 - S22
  • [7] Chiao RY, 1997, 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, P1679, DOI 10.1109/ULTSYM.1997.663318
  • [8] SUPER-RESOLUTION ULTRASOUND IMAGING
    Christensen-Jeffries, Kirsten
    Couture, Olivier
    Dayton, Paul A.
    Eldar, Yonina C.
    Hynynen, Kullervo
    Kiessling, Fabian
    O'Reilly, Meaghan
    Pinton, I. Gianmarco F.
    Schmitz, Georg
    Tang, Meng-Xing
    Tanter, Mickael
    Van Sloun, Ruud J. G.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (04) : 865 - 891
  • [9] Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
    Couture, Olivier
    Hingot, Vincent
    Heiles, Baptiste
    Muleki-Seya, Pauline
    Tanter, Mickael
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (08) : 1304 - 1320
  • [10] ULTRAFAST IMAGING OF ULTRASOUND CONTRAST AGENTS
    Couture, Olivier
    Bannouf, Souad
    Montaldo, Gabriel
    Aubry, Jean-Francois
    Fink, Mathias
    Tanter, Mickael
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (11) : 1908 - 1916