Modelling the ingress and charge enhanced deposition behaviour of radioactive aerosols in dwellings

被引:2
作者
Din, Tashfeen Muhammad Hammad Ud [1 ]
Byrne, Miriam A. [1 ]
McGrath, James A. [1 ,2 ]
机构
[1] Univ Galway, Ryan Inst Ctr Climate & Air Pollut Studies, Sch Nat Sci, Phys, Univ Rd, Galway H91 CF50, Ireland
[2] Maynooth Univ, Dept Expt Phys, Maynooth, Kildare, Ireland
关键词
Indoor air quality; Radioactive aerosol; Aerosol charge; Computational modelling; Multizone modelling; Deposition velocity; SIZE DISTRIBUTIONS; EXPOSURE; AIR; RADIONUCLIDES; BUILDINGS;
D O I
10.1016/j.atmosenv.2023.119793
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radioactive aerosols of accidental origin can travel long distances once airborne and although dwellings can provide some shelter, ingressed radioactive aerosol has been shown to be injurious to human health. Modelling approaches have been widely used to study indoor aerosol behaviour, but such approaches have not to date considered the self-charging nature of radioactive aerosol and the consequent effect upon aerosol deposition. In this work, a multi-zone modeling tool is used to simulate indoor aerosol concentrations in the individual rooms of a bungalow and semi-detached dwelling, for three radioactive aerosol particles sizes (0.5, 1.0, 2.0 mu m, with aerosol deposition enhancement due to particle charge), two plume types (5 h and 24 h), and a range of representative dwelling airflow conditions (low air flow LAF and high air flow HAF1), including mechanical extract ventilation (HAF2). When comparing the time series of aerosol concentrations in different rooms, lower concentrations of charged aerosol, relative to uncharged, were observed, suggesting charge-enhanced deposition, and this phenomena is more striking during a 24 h plume compared to 5 h plume, where the difference between the two is up to 50% in one of the zones of the dwelling. The concentration comparison of charged aerosols concentration between LAF and HAF1 cases also showed that during a 5 h plume, the aerosol concentration is twice as high for the HAF1 case. These simulation results demonstrate that the effect of charged-enhanced aerosol deposition should be considered when assessing the benefits of sheltering in a building in the event of a nuclear accident.
引用
收藏
页数:11
相关论文
共 49 条
[1]  
Balonov M., 2013, ENCY ENV HLTH, P448
[2]   The removal of radioactive aerosols by electric fields [J].
Barrett, J. C. ;
Clement, C. F. ;
Virdee, A. B. S. .
JOURNAL OF AEROSOL SCIENCE, 2009, 40 (03) :185-192
[3]   Experimental study of radioactive aerosols in the vicinity of the Chernobyl Nuclear Power Plant [J].
Boulyga, SF ;
Lomonosova, EM ;
Zhuk, IV ;
Yaroshevich, OI ;
Kudrjashov, VP ;
Mironov, VP .
RADIATION MEASUREMENTS, 1999, 30 (06) :703-707
[4]   STABLE TRACER AEROSOL DEPOSITION MEASUREMENTS IN A TEST CHAMBER [J].
BYRNE, MA ;
GODDARD, AJH ;
LANGE, C ;
ROED, J .
JOURNAL OF AEROSOL SCIENCE, 1995, 26 (04) :645-653
[5]  
Central Statistics Office, 2017, CENS POP 2016 PROF 1
[6]   Effectiveness of urban shelter-in-place-II: Residential districts [J].
Chan, Wanyu R. ;
Nazaroff, William W. ;
Price, Phillip N. ;
Gadgil, Ashok J. .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (33) :7082-7095
[7]   Effectiveness of urban shelter-in-place-I: Idealized conditions [J].
Chan, Wanyu R. ;
Nazaroff, William W. ;
Price, Phillip N. ;
Gadgil, Ashok J. .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (23) :4962-4976
[8]   Protecting building occupants against the inhalation of outdoor-origin aerosols [J].
Dillon, Michael B. ;
Sextro, Richard G. ;
Delp, W. Woody .
ATMOSPHERIC ENVIRONMENT, 2022, 268
[9]   INDAIR: A probabilistic model of indoor air pollution in UK homes [J].
Dimitroulopoulou, C. ;
Ashmore, M. R. ;
Hill, M. T. R. ;
Byrne, M. A. ;
Kinnersley, R. .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (33) :6362-6379
[10]   A Test Chamber Investigation of the Effect of Charging on Aerosol Deposition on Indoor Surfaces [J].
Din, Tashfeen Muhammad Hammad Ud ;
McGrath, James A. ;
Byrne, Miriam A. .
AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (12) :2669-2680