Local volumetric mass transfer coefficients in sections of multiple-impeller stirred tank reactors: Data analysis

被引:2
作者
Zak, Adrian [1 ]
Zednikova, Maria [1 ,2 ]
Moucha, Tomas [1 ]
机构
[1] Univ Chem & Technol Prague, Dept Chem Engn, Tech 5, Prague 6, Czech Republic
[2] CAS, Inst Chem Proc Fundamentals, Rozvojova 135, Prague 6, Czech Republic
关键词
Gas -liquid mass transfer; Fermenters design; Hydrodynamics; Impellers pumping intensity; DYNAMIC PRESSURE METHOD; GAS-LIQUID; POWER-CONSUMPTION; INDIVIDUAL STAGES; RUSHTON TURBINES; KLA MEASUREMENT; K(L)A VALUES; BIOREACTORS; DISPERSION; VESSELS;
D O I
10.1016/j.cherd.2023.01.001
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The analysis of local values of volumetric mass transfer coefficient, kLa, was performed to identify the effects of local hydrodynamics on the mass transfer rate in multiple-impeller stirred tank reactors. The database of kLa values measured by Dynamic Pressure Method was analysed. The database provides data for two vessel sizes (laboratory and pilot-scale reactor), a wide range of operational conditions (gas flow rate, impeller speed), various impeller geometries and sizes and four different batches including viscous media. The local kLa values in multiple impeller configurations were measured in several positions corresponding to the individual impeller regions. The overall kLa value averaged through the whole volume is considered as the best representation of the correct kLa value. Different hydrodynamic effects on mass transfer rate were obtained in the two end re-gions. In the bottom region, the local kLa values increase with impeller speed faster than the overall kLa. The opposite behaviour was obtained in the uppermost region corre-sponding to the decrease of power consumption and the mass transfer rate with in-creasing surface aeration under high impeller speeds. The best representation of the overall kLa value was obtained in the middle position of the vessel, where the exchange flows bring the liquid saturated to different measure from the end regions. Even if the local kLa data in individual impellers' regions are shifted to the average values due to the inter-impeller exchange flows, the differences between them are still significant. We show the local kLa values by the combination of the data measured at different liquid level heights. The results can be used in the fermenter design with various impeller combi-nations.(c) 2023 Institution of Chemical Engineers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:829 / 841
页数:13
相关论文
共 51 条