A systematic framework for the assessment of the reliability of energy supply in Integrated Energy Systems based on a quasi-steady-state model

被引:21
作者
Chi, Lixun [1 ,2 ]
Su, Huai [1 ]
Zio, Enrico [3 ,4 ]
Qadrdan, Meysam [5 ]
Zhou, Jing [1 ]
Zhang, Li [1 ]
Fan, Lin [1 ]
Yang, Zhaoming [1 ]
Xie, Fei [6 ]
Zuo, Lili [1 ]
Zhang, Jinjun [1 ]
机构
[1] China Univ Petr, Natl Engn Lab Pipeline Safety, MOE Key Lab Petr Engn, Beijing Key Lab Urban Oil & Gas Distribut Technol, Beijing 102249, Peoples R China
[2] China Natl Petr Corp, PetroChina Planning & Engn Inst, 9 Dongzhimen North St, Beijing 100007, Peoples R China
[3] Politecn Milan, Dipartimento Energia, Via Masa 34, I-20156 Milan, Italy
[4] Kyung Hee Univ, Coll Engn, Dept Nucl Engn, Seoul, South Korea
[5] Cardiff Univ, Sch Engn, Cardiff, Wales
[6] Natl Petr & Nat Gas Pipeline Network Grp Co LTD, North China Branch, Tianjin 300000, Peoples R China
基金
中国国家自然科学基金;
关键词
Reliability assessment; Quasi -steady-state model; CSML model; POWER-TO-GAS; NATURAL-GAS; FAILURE PROBABILITY; UNCERTAINTY ANALYSIS; ELECTRICITY NETWORK; INFRASTRUCTURES; COPULA; IMPACT; STRATEGIES; FLOW;
D O I
10.1016/j.energy.2022.125740
中图分类号
O414.1 [热力学];
学科分类号
摘要
The reliability analysis of IESs (Integrated Energy Systems) is a complicated task because of the complex char-acteristics of different subsystems and the multi-scale dynamics that develop therein. To effectively address such problems, this paper proposes a systematic framework to analyse the reliability of energy supply in IESs, considering the dynamics of IESs and the inter-relationships among uncertainties. First, based on the linepack-based performance analysis model of IES, a quasi-steady-state model is established to model the dynamic be-haviours in IESs, properly accounting for practical engineering and operational strategies. Then, considering the inter-correlations among different uncertainty sources and time-dependent relationships of each variable, a model that combines the statistical structure of copula with the machine learning method of stacked autoencoder (CSML) is adopted to establish the timely multivariate joint distributions for variables. Monte Carlo simulation combined with Order Statistics is used for assessing supply reliability. Case studies are performed on a realistic IES that combines an IEEE-15 power system with an 18-node natural gas pipeline network. The efficiency and accuracy of the quasi-steady-state model are validated. The reliability evaluation results show that the inter -correlations among variables and time-dependent relationships of each variable have great effects on the sys-tem reliability assessment. The consideration of linepack can significantly improve the supply reliability of IES whereas the management strategy of linepack may lead to some risky points.
引用
收藏
页数:17
相关论文
共 59 条
  • [1] Coordination of Interdependent Natural Gas and Electricity Infrastructures for Firming the Variability of Wind Energy in Stochastic Day-Ahead Scheduling
    Alabdulwahab, Ahmed
    Abusorrah, Abdullah
    Zhang, Xiaping
    Shahidehpour, Mohammad
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (02) : 606 - 615
  • [2] Reliability analysis and functional design using Bayesian networks generated automatically by an "Idea Algebra" framework
    Amrin, Andas
    Zarikas, Vasileios
    Spitas, Christos
    [J]. RELIABILITY ENGINEERING & SYSTEM SAFETY, 2018, 180 : 211 - 225
  • [3] Recent development in copula and its applications to the energy, forestry and environmental sciences
    Bhatti, M. Ishaq
    Hung Quang Do
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (36) : 19453 - 19473
  • [4] Empirical and sequential empirical copula processes under serial dependence
    Buecher, Axel
    Volgushev, Stanislav
    [J]. JOURNAL OF MULTIVARIATE ANALYSIS, 2013, 119 : 61 - 70
  • [5] Multi-time period combined gas and electricity network optimisation
    Chaudry, Modassar
    Jenkins, Nick
    Strbac, Goran
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (07) : 1265 - 1279
  • [6] Data-driven reliability assessment method of Integrated Energy Systems based on probabilistic deep learning and Gaussian mixture Model-Hidden Markov Model
    Chi, Lixun
    Su, Huai
    Zio, Enrico
    Qadrdan, Meysam
    Li, Xueyi
    Zhang, Li
    Fan, Lin
    Zhou, Jing
    Yang, Zhaoming
    Zhang, Jinjun
    [J]. RENEWABLE ENERGY, 2021, 174 : 952 - 970
  • [7] Integrated Deterministic and Probabilistic Safety Analysis of Integrated Energy Systems with bi-directional conversion
    Chi, Lixun
    Su, Huai
    Zio, Enrico
    Zhang, Jinjun
    Li, Xueyi
    Zhang, Li
    Fan, Lin
    Zhou, Jing
    Bai, Hua
    [J]. ENERGY, 2020, 212
  • [8] Integrated Modeling and Assessment of the Operational Impact of Power-to-Gas (P2G) on Electrical and Gas Transmission Networks
    Clegg, Stephen
    Mancarella, Pierluigi
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (04) : 1234 - 1244
  • [9] Smart Energy Europe: The technical and economic impact of one potential 100% renewable energy scenario for the European Union
    Connolly, D.
    Lund, H.
    Mathiesen, B. V.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 : 1634 - 1653
  • [10] Cw A, 2021, FAST SUPPLY RELIABIL, P208