Higher sensitivity and accuracy of synovial next-generation sequencing in comparison to culture in diagnosing periprosthetic joint infection: a systematic review and meta-analysis

被引:16
作者
Hantouly, Ashraf T. [1 ]
Alzobi, Osama [1 ]
Toubasi, Ahmad A. [2 ]
Zikria, Bashir [3 ]
Al Dosari, Mohammed Al Ateeq [1 ]
Ahmed, Ghalib [1 ]
机构
[1] Hamad Med Corp, Surg Specialty Ctr, Dept Orthoped Surg, Doha, Qatar
[2] Univ Jordan, Fac Med, Amman, Jordan
[3] Aspetar Orthopaed & Sports Med Hosp, Doha, Qatar
关键词
Periprosthetic joint infection; Arthroplasty; Diagnosis; Next-generation sequencing; Culture; BACTERIA; FLUID;
D O I
10.1007/s00167-022-07196-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this meta-analysis was to compare the diagnostic parameters of synovial next-generation sequencing (NGS) and cultures in diagnosing periprosthetic joint infections (PJI). Methods PubMed, Web of Science, Cochrane, and Google Scholar were searched from inception until 8 Jan 2022 for literature investigating the role of NGS in comparison to culture in the diagnosis of PJI. The studies were included if they investigated the diagnostic value of culture and NGS in diagnosing PJIs against the Musculoskeletal Infection Society (MSIS) criteria. Diagnostic parameters, such as sensitivity, specificity, positive predictive value, negative predictive value, positive-likelihood ratio, negative-likelihood ratio, accuracy, and area under the curve (AUC), were calculated for the included studies to evaluate the performance of NGS in comparison to culture in PJI diagnosis. Results The total number of the included patients was 341 from seven articles. The pooled sensitivity, specificity, and diagnostic odds ratio of NGS were 94% (95% CI 91-97%), 89% (95% CI 82-95%), and 138.5 (95% CI 49.1-390.5), respectively. NGS has positive- and negative-likelihood ratios of 7.9 (95% CI 3.99-15.6) and 0.1 (95% CI 0.0-0.1), respectively. On the other hand, the pooled sensitivity, specificity, and diagnostic odds ratio of culture were 70% (95% CI 61-79%), 94% (95% CI 88-98%), and 28.0 (95% CI 12.6-62.2), respectively. The SROC curve for NGS showed that the accuracy (AUC) was 91.9%, and that the positive and negative predictive values were 8.6 (95% CI 5.0-19.5) and 0.1 (95% CI 0.0-0.1), respectively. While, culture SROC curve demonstrated that the accuracy (AUC) was 80.5% and the positive- and negative-likelihood ratio were 12.1 (95% CI 4.5-49.6) and 0.3 (95% CI 0.2-0.4). Conclusions NGS has a potential role in diagnosing hip and knee PJIs due to its high sensitivity, specificity, and accuracy. However, the sensitivity and specificity reported by the studies varied according to the time of synovial sampling (preoperative, postoperative, or mixed).
引用
收藏
页码:3672 / 3683
页数:12
相关论文
共 29 条
[21]  
Tan Timothy L, 2018, JB JS Open Access, V3, pe0060, DOI [10.2106/jbjs.oa.17.00060, 10.2106/JBJS.OA.17.00060]
[22]   Diagnosis of Periprosthetic Joint Infection: The Potential of Next-Generation Sequencing [J].
Tarabichi, Majd ;
Shohat, Noam ;
Goswami, Karan ;
Alvand, Abtin ;
Silibovsky, Randi ;
Belden, Katherine ;
Parvizi, Javad .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (02) :147-154
[23]   Comparison of microbial DNA enrichment tools for metagenomic whole genome sequencing [J].
Thoendel, Matthew ;
Jeraldo, Patricio R. ;
Greenwood-Quaintance, Kerryl E. ;
Yao, Janet Z. ;
Chia, Nicholas ;
Hanssen, Arlen D. ;
Abdel, Matthew P. ;
Patel, Robin .
JOURNAL OF MICROBIOLOGICAL METHODS, 2016, 127 :141-145
[24]   Evaluation and interpretation of prosthetic joint infection diagnostic investigations [J].
Trebse, Rihard ;
Roskar, Samo .
INTERNATIONAL ORTHOPAEDICS, 2021, 45 (04) :847-855
[25]   Comparison of broad-range polymerase chain reaction and metagenomic next-generation sequencing for the diagnosis of prosthetic joint infection [J].
Wang, Chao-xin ;
Huang, Zida ;
Fang, Xinyu ;
Li, Wenbo ;
Yang, Bin ;
Zhang, Wenming .
INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 95 :8-12
[26]   QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies [J].
Whiting, Penny F. ;
Rutjes, Anne W. S. ;
Westwood, Marie E. ;
Mallett, Susan ;
Deeks, Jonathan J. ;
Reitsma, Johannes B. ;
Leeflang, Mariska M. G. ;
Sterne, Jonathan A. C. ;
Bossuyt, Patrick M. M. .
ANNALS OF INTERNAL MEDICINE, 2011, 155 (08) :529-U104
[27]   Diagnostic value of next-generation sequencing to detect periprosthetic joint infection [J].
Yin, Han ;
Xu, Duliang ;
Wang, Dawei .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[28]  
Yoon Hong-Kwon, 2017, Knee Surg Relat Res, V29, P155, DOI [10.5792/ksrr.16.034, 10.5792/ksrr.16.034]
[29]   Value of mNGS in sonication fluid for the diagnosis of periprosthetic joint infection [J].
Zhang, Chongjing ;
Fang, Xinyu ;
Huang, Zida ;
Li, Wenbo ;
Zhang, Chao-fan ;
Yang, Bin ;
Zhang, Wenming .
ARTHROPLASTY, 2019, 1 (01)