Determination of lead and cadmium by magnetic solid-phase extraction (MSPE) using Co3O4@Fe3O4 nanoflowers and flame atomic absorption spectrometry (FAAS)

被引:3
作者
Korkmaz, Seyma [1 ]
Yetim, Nurdan Kurnaz [1 ]
Koc, Mumin Mehmet [2 ,3 ]
Ozcan, Cemile [1 ]
机构
[1] Kirklareli Univ, Fac Arts & Sci, Dept Chem, Kirklareli, Turkiye
[2] Kirklareli Univ, Fac Arts & Sci, Dept Phys, Kirklareli, Turkiye
[3] Kirklareli Univ, Sch Med Serv, Kirklareli, Turkiye
关键词
Magnetic solid-phase extraction (MSPE); Co3O4@Fe3O4-doped nanoflowers; Flame atomic absorption spectrometry (FAAS); HEAVY-METALS; WASTE-WATER; NANOPARTICLES; REMOVAL; CD(II); PB(II); CO(II); NANOCOMPOSITE; ADSORPTION; SEPARATION;
D O I
10.1007/s11696-024-03413-6
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Heavy metal ions penetrate wastewater and clean water sources, leading to environmental pollution which adversely affecting human health. The determination and extraction of metal ions help to prevent unwanted effects on the environment and human health. Solid phase extraction method is used for the removal of heavy metal ions. Such method is rapid, reliable and affordable method which provide high recovery rate. For this purpose, cobalt(II/III) oxide@iron(II/III) oxide (Co3O4@Fe3O4) core-shell composite nanoflowers were fabricated via hydrothermal synthesis for the recovery of heavy metal ions (Pb2+ and Cd2+). X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and vibrating sample magnetometry (VSM) were used in the chemical and structural characterization of Co3O4@Fe3O4. Flame atomic absorption spectrometry (FAAS) was used for the determination of total metal content. In our work, optimum conditions for heavy metal on recovery such as eluent concentration, eluent type, pH, adsorbent amount, solution volume, sonication duration, were studied. As a result of these studies, quantitative recovery of analyte ions was obtained at pH 7.5. Quantitative recovery of Pb2+ ions was observed with 20 mL 1 M HNO3 solution as eluent and 100 mg amount of adsorbent while, they were found for Cd2+ ion recovery with 5 mL 1 M HNO3 solution as eluent and 200 mg amount of adsorbent. The highest recovery rates were found to be 99.6% and 99.9% for Pb2+ and Cd2+ heavy metal ions, respectively.
引用
收藏
页码:4495 / 4506
页数:12
相关论文
共 50 条
  • [1] Ultrasound-Assisted Dispersive Magnetic Solid-Phase Extraction Using Fe3O4@Hydroxypropyl Methylcellulose Combined with Flame Atomic Absorption Spectrometry for Determination of Cadmium(II) in Food Samples
    Esmaeili Lashkarian, Elham
    Ahmadi, Shahin
    Beigmohammadi, Faranak
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (01) : 209 - 219
  • [2] Magnetic Solid Phase Extraction of Lead (II) and Cadmium (II) From Water Samples Using ZnO@Fe3O4 Nanoparticles Combined With Flame Atomic Absorption Spectrometry Determination
    Korkmaz, Seyma
    Ozkan, Elvan Hasanoglu
    Uzun, Demet
    Yetim, Nurdan Kurnaz
    Ozcan, Cemile
    JOURNAL OF SEPARATION SCIENCE, 2025, 48 (03)
  • [3] Rapid Determination of Cadmium and Lead in Maca (Lepidium meyenii) by Magnetic Solid-Phase Extraction and Flame Atomic Absorption Spectrometry
    Ju, Shuangqiao
    Yu, Jianping
    Ma, Yanqiong
    Yang, Yaling
    Liu, Mousheng
    ANALYTICAL LETTERS, 2015, 48 (16) : 2566 - 2580
  • [4] Preconcentration and Determination of Cadmium, Lead, and Cobalt in Moringa Oleifera (Moringaceae) Using Magnetic Solid-Phase Extraction and Flame Atomic Absorption Spectrometry
    Ju, Shuangqiao
    Liu, Mousheng
    Yang, Yaling
    ANALYTICAL LETTERS, 2016, 49 (04) : 511 - 522
  • [5] Determination of Rhodium in Soil by Dispersive Solid-Phase Extraction (DSPE) with Manganese Ferrite Nanoparticles and Flame Atomic Absorption Spectrometry (FAAS)
    Serbest, Hakan
    ANALYTICAL LETTERS, 2024, 57 (03) : 456 - 468
  • [6] Rapid determination of copper and lead in Panax notoginseng by magnetic solid-phase extraction and flame atomic absorption spectrometry
    Yin, Qinhong
    Zhu, Yanqin
    Ju, Shuangqiao
    Liao, Wenlong
    Yang, Yaling
    RESEARCH ON CHEMICAL INTERMEDIATES, 2016, 42 (05) : 4985 - 4998
  • [7] Magnetic solid-phase extraction of U(VI) in aqueous solution by Fe3O4@hydroxyapatite
    Zeng, Dejun
    Dai, Ying
    Zhang, Zhibing
    Wang, Youqun
    Cao, Xiaohong
    Liu, Yunhai
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 324 (03) : 1329 - 1337
  • [8] Solid Phase Extraction of Cadmium and Lead from Water by Amberlyst 15 and Determination by Flame Atomic Absorption Spectrometry
    Tunceli, Adalet
    Ulas, Abdullah
    Acar, Orhan
    Turker, Ali Rehber
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2019, 102 (02) : 297 - 302
  • [9] Magnetic nanobiosorbent (MG-Chi/Fe3O4) for dispersive solid-phase extraction of Cu(II), Pb(II), and Cd(II) followed by flame atomic absorption spectrometry determination
    Salehi, Narges
    Moghimi, Ali
    Shahbazi, Hamidreza
    IET NANOBIOTECHNOLOGY, 2021, 15 (06) : 575 - 584
  • [10] Determination of lead and cadmium in water samples by magnetic solid-phase extraction with iron oxide@silicon oxide-graphene oxide (Fe3O4@SiO2-GO) hybrid magnetic nanoparticles and microinjection sampling flame atomic absorption spectrometry
    Baykal, Gulser
    Kazan, Damla
    Seval, Kadir
    Bulut, Duygu Takanoglu
    Elci, Sukru Gokhan
    Divrikli, Umit
    Akdogan, Abdullah
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2021, 50 (03) : 288 - 305