Integrated absolute full energy peak efficiency: A measure of photon registration efficiency

被引:1
作者
Jednorog, Slawomir [1 ]
Klis, Bartlomiej [1 ]
Szewczak, Kamil [2 ]
机构
[1] Cent Lab Radiol Protect, Konwaliowa 7, PL-03194 Warsaw, Poland
[2] Polish Acad Sci, Inst Agrophys, Doswiadczalna 4, PL-20290 Lublin, Poland
关键词
Gamma spectrometry; Absolute full energy peak efficiency; Integrated absolute full energy peak efficiency; CALIBRATION;
D O I
10.1016/j.apradiso.2024.111237
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Integrated absolute full energy peak efficiency (IAFEPE) is a measure of photon registration efficiency using the gamma-ray spectrometry method. We have derived appropriate formulas and theoretical explanations of IAFEPE for the first time. IAFEPE is a definite integral (Riemann integral) of the photon registration efficiency function within the detection energy range. IAFEPE, along with associated quantities such as mass integrated absolute full energy peak efficiency and surface integrated absolute full energy peak efficiency, allows for the quantitative validation of measurement conditions.
引用
收藏
页数:8
相关论文
共 23 条
[1]   HPGe detector absolute full-energy peak efficiency calibration including coincidence correction for circular disc sources [J].
Abbas, Mahmoud I. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (18) :3952-3958
[2]  
Batistoni, 2018, NUCL FUSION, V58, P106016
[3]   14 MeV calibration of JET neutron detectors-phase 1: calibration and characterization of the neutron source [J].
Batistoni, P. ;
Popovichev, S. ;
Cufar, A. ;
Ghani, Z. ;
Giacomelli, L. ;
Jednorog, S. ;
Klix, A. ;
Lilley, S. Y. ;
Laszynska, E. ;
Loreti, S. ;
Packer, L. ;
Peacock, A. ;
Pillon, M. ;
Price, R. ;
Rebai, M. ;
Rigamonti, D. ;
Roberts, N. ;
Tardocchi, M. ;
Thomas, D. ;
Litaudon, X. ;
Abduallev, S. ;
Abhangi, M. ;
Abreu, P. ;
Afzal, M. ;
Aggarwal, K. M. ;
Ahlgren, T. ;
Ahn, J. H. ;
Aho-Mantila, L. ;
Aiba, N. ;
Airila, M. ;
Albanese, R. ;
Aldred, V. ;
Alegre, D. ;
Alessi, E. ;
Aleynikov, P. ;
Alfier, A. ;
Alkseev, A. ;
Allinson, M. ;
Alper, B. ;
Alves, E. ;
Ambrosino, G. ;
Ambrosino, R. ;
Amicucci, L. ;
Amosov, V. ;
Sunden, E. Andersson ;
Angelone, M. ;
Anghel, M. ;
Angioni, C. ;
Appel, L. ;
Appelbee, C. .
NUCLEAR FUSION, 2018, 58 (02)
[4]   Nuclear data sheets for A=137 [J].
Browne, E. ;
Tuli, J. K. .
NUCLEAR DATA SHEETS, 2007, 108 (10) :2173-+
[5]   Evaluation of efficiency for in situ gamma spectrometer based upon cerium-doped lanthanum bromide detector dedicated for environmental radiation monitoring [J].
Ciupek, Krzysztof ;
Jednorog, Slawomir ;
Fujak, Marian ;
Szewczak, Kamil .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (03) :1345-1350
[6]  
Cooke P., 1989, AEA Culham Laboratory report CLM-R298
[7]   A NUMERICAL METHOD FOR THE CALIBRATION OF IN SITU GAMMA RAY SPECTROSCOPY SYSTEMS [J].
Dewey, S. C. ;
Whetstone, Z. D. ;
Kearfott, K. J. .
HEALTH PHYSICS, 2010, 98 (05) :657-671
[8]   A novel technique for the optimization and reduction of gamma spectroscopy geometry uncertainties [J].
Frosio, Thomas ;
Menaa, Nabil ;
Bertreix, Philippe ;
Rimlinger, Maeva ;
Theis, Chris .
APPLIED RADIATION AND ISOTOPES, 2020, 156
[9]  
Gilmore G., 2011, PRACTICAL GAMMA RAY, V2nd
[10]   Absolute peak-efficiency calibration of a well-type germanium detector using multiple gamma-emitting nuclides with the "Solver" add-in in Excel™ [J].
Ishizu, H. ;
Yamada, T. .
APPLIED RADIATION AND ISOTOPES, 2017, 126 :158-161