Minimizing Surgeon Radiation Exposure During Operative Treatment of Pediatric Supracondylar Humerus Fractures

被引:0
作者
Montgomery, Blake K. [1 ,3 ]
Cidambi, Emily O. [4 ]
Birch, Craig M. [1 ,3 ]
Wang, Kemble [5 ]
Miller, Patricia E. [1 ]
Kim, Don-Soo [2 ]
Shore, Benjamin J. [1 ,3 ,6 ]
机构
[1] Boston Childrens Hosp, Dept Orthopaed Surg, Boston, MA USA
[2] Boston Childrens Hosp, Dept Radiol, Boston, MA USA
[3] Harvard Med Sch, Boston, MA USA
[4] Rady Childrens Hosp, Dept Orthopaed Surg, San Diego, CA USA
[5] Melbourne Orthopaedic Surgeon, East Melbourne, Australia
[6] Boston Childrens Hosp, Dept Orthopaed Surg, 300 Longwood Ave, Boston, MA 02215 USA
关键词
radiation; C-arm; fluoroscopy; supracondylar humerus fracture; CANCER; PREVALENCE; POSITION;
D O I
10.1097/BPO.0000000000002421
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background:Orthopaedic surgeons are exposed to high levels of radiation, which may lead to higher rates of cancer among orthopaedic surgeons. There are a series of techniques currently practiced to pin supracondylar humerus fractures including pinning the arm on the C-arm itself, using a plexiglass rectangle or a graphite floating arm board; however, the variation in radiation exposure to the surgeon is unknown. We aimed to determine how the position of the C-arm affects radiation exposure to the surgeon during the treatment of a pediatric supracondylar humerus fracture. Material and Methods:A simulated operating room was created to simulate a closed reduction and percutaneous pinning of a supracondylar humerus fracture. A phantom model was used to simulate the patient's arm. We assessed performing the procedure with the arm on plexiglass, graphite, or on top of the C-arm image receptor. The C-arm was positioned either with the source down and image receptor up (standard position) or with the source up and image receptor down (inverted position). Radiation exposure was recorded from levels corresponding to the surgeon's head, midline, and groin. The estimated effective dose equivalent was calculated to account for the varying radiation sensitivity of different organs. Results:We found the effective dose equivalent, or the overall body damage from radiation, was 5.4 to 7.8% higher than the surgeon when the C-arm was in the inverted position (source up, image receptor down). We did not find any differences in radiation exposure to the surgeon when the arm was supported on plexiglass versus graphite. Conclusion:The C-arm positioned in the standard fashion exposes the surgeon to less damaging radiation. Therefore, when the surgeon is standing, we recommend using the C-arm in the standard position.
引用
收藏
页码:414 / 417
页数:4
相关论文
共 15 条
[1]  
[Anonymous], 2010, United States Nuclear Regulatory Commission Technical Training Center Rev 325C
[2]  
[Anonymous], 1996, N13411997 ANSIHPS
[3]   Increased Breast Cancer Prevalence Among Female Orthopedic Surgeons [J].
Chou, Loretta B. ;
Chandran, Sheena ;
Harris, Alex H. S. ;
Tung, Joanna ;
Butler, Lesley M. .
JOURNAL OF WOMENS HEALTH, 2012, 21 (06) :683-689
[4]   Prevalence of Cancer in Female Orthopedic Surgeons in the United States [J].
Chou, Loretta B. ;
Cox, Christopher A. ;
Tung, Joanna J. ;
Harris, Alex H. S. ;
Brooks-Terrell, Daria ;
Sieh, Weiva .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (01) :240-244
[5]   Direct Beam Radiation Exposure to Surgeons During Pinning of Supracondylar Humerus Fractures: Does C-Arm Position and the Attending Surgeon Matter? [J].
Eismann, Emily A. ;
Wall, Eric J. ;
Thomas, Elizabeth C. ;
Little, Megan A. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2014, 34 (02) :166-171
[6]   The Effect of C-Arm Position on Radiation Exposure During Fixation of Pediatric Supracondylar Fractures of the Humerus [J].
Hsu, Raymond Y. ;
Lareau, Craig R. ;
Kim, Jeom Soon ;
Koruprolu, Sarath ;
Born, Christopher T. ;
Schiller, Jonathan R. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (15) :e129(1)
[7]   Intraoperative risks of radiation exposure for the surgeon and patient [J].
Jenkins, Nathaniel W. ;
Parrish, James M. ;
Sheha, Evan D. ;
Singh, Kern .
ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (01)
[8]   Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine [J].
Jones, DPG ;
Robertson, PA ;
Lunt, B ;
Jackson, SA .
SPINE, 2000, 25 (12) :1538-1541
[9]   Intraoperative radiation safety in orthopaedics: A review of the ALARA (As low as reasonably achievable) principle [J].
Kaplan D.J. ;
Patel J.N. ;
Liporace F.A. ;
Yoon R.S. .
Patient Safety in Surgery, 10 (1)
[10]   Measurements of Surgeons' Exposure to Ionizing Radiation Dose During Intraoperative Use of C-Arm Fluoroscopy [J].
Lee, Kisung ;
Lee, Kyoung Min ;
Park, Moon Seok ;
Lee, Boram ;
Kwon, Dae Gyu ;
Chung, Chin Youb .
SPINE, 2012, 37 (14) :1240-1244