ECG R-Wave Detection and Its Application in Left Ventricular Assist Device

被引:0
|
作者
Yan, Rongguo [1 ]
Wang, Jie [1 ]
Wang, Jiahui [1 ]
Shao, Hongran [1 ]
Fang, Xuchen [2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
[2] Shidong Hosp, Dept Intens Care Unit, Shanghai 200438, Peoples R China
关键词
Real-time R-wave detection; field programmable gate array; ECG signal; left ventricular assist; Shannon energy;
D O I
10.1142/S0218126623503085
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Heart failure is one of the major diseases endangering human life. As a transitional support treatment before heart transplantation, the left ventricular assist device (LVAD) has significantly improved the quality of life and survival rate of patients with end-stage heart failure. In the automatic detection of electrocardiogram (ECG), the detection of QRS wave groups is the most critical aspect, which affects the correctness and accuracy of subsequent data analysis and processing. The paper used the data from the MIT-BIH database and the data collected from human ECG as the original number of samples for further processing. It processed the data through a high-order finite impulse response (FIR) low-pass filter and Shannon energy algorithm, and added the use of a high-order adaptive median filter algorithm on a field programmable gate array (FPGA) to minimize the noise of the processed real-time data. Finally, the tested ECG R-wave was used to drive the LVAD. After successful simulation by MATLAB and Modelsim software, the scheme of the real-time ECG signal controlling blood pump system was realized on the FPGA platform. The experiment showed that the method proposed could accurately extract the R-wave and control the LVAD to pump blood simultaneously.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] R-WAVE AMPLITUDE WITH EXERCISE - RELATION TO LEFT-VENTRICULAR VOLUME VARIATION
    TAMARI, I
    HOCHREITER, C
    NILES, N
    SATO, N
    KLIGFIELD, P
    DEVEREUX, R
    BORER, J
    CLINICAL RESEARCH, 1988, 36 (03): : A322 - A322
  • [22] R-WAVE AMPLITUDE WITH EXERCISE - RELATION TO LEFT-VENTRICULAR VOLUME VARIATION
    TAMARI, I
    HOCHREITER, C
    NILES, N
    SATO, N
    KLIGFIELD, P
    DEVEREUX, R
    BORER, JS
    CLINICAL RESEARCH, 1987, 35 (03): : A329 - A329
  • [23] R-WAVE AMPLITUDE WITH EXERCISE - RELATION TO LEFT-VENTRICULAR VOLUME VARIATION
    TAMARI, I
    HOCHREITER, C
    NILES, N
    SATO, N
    KLIGFIELD, P
    DEVEREUX, R
    BORER, JS
    CLINICAL RESEARCH, 1986, 34 (03): : A864 - A864
  • [24] A CORRELATIVE STUDY OF R-WAVE AMPLITUDE AND LEFT-VENTRICULAR FUNCTION AT REST
    GODISH, D
    ROTMENSCH, HH
    BRAUN, S
    LANIADO, S
    CLINICAL RESEARCH, 1982, 30 (02): : A189 - A189
  • [25] ECG POOR R-WAVE PROGRESSION - REVIEW AND SYNTHESIS
    ZEMA, MJ
    KLIGFIELD, P
    ARCHIVES OF INTERNAL MEDICINE, 1982, 142 (06) : 1145 - 1148
  • [26] Atrophy of myocardium and its myocytes by left ventricular assist device
    Soloff, LA
    CIRCULATION, 1999, 100 (09) : 1012 - 1012
  • [27] Ventricular arrhythmias and left ventricular assist device
    Ozcan, Cevher
    Barrett, Conor D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : E81 - E83
  • [28] Pulse wave analysis in the assessment of patients with left ventricular assist device
    Vlachopoulos, C
    Mcdonald, P
    Spratt, P
    O'Rourke, M
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2001, 20 (01): : 98 - 102
  • [29] IMPLANTATION TECHNIQUE FOR THE HEARTMATE(R) LEFT-VENTRICULAR ASSIST DEVICE
    RADOVANCEVIC, B
    FRAZIER, OH
    DUNCAN, JM
    JOURNAL OF CARDIAC SURGERY, 1992, 7 (03) : 203 - 207
  • [30] A real-time R-wave detection method for wireless ambulatory ECG telemetry
    Dai, Chenchen
    Deng, Yan
    Chen, Feifan
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2015, 19 (01) : 26 - 39