ECG R-Wave Detection and Its Application in Left Ventricular Assist Device

被引:0
|
作者
Yan, Rongguo [1 ]
Wang, Jie [1 ]
Wang, Jiahui [1 ]
Shao, Hongran [1 ]
Fang, Xuchen [2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
[2] Shidong Hosp, Dept Intens Care Unit, Shanghai 200438, Peoples R China
关键词
Real-time R-wave detection; field programmable gate array; ECG signal; left ventricular assist; Shannon energy;
D O I
10.1142/S0218126623503085
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Heart failure is one of the major diseases endangering human life. As a transitional support treatment before heart transplantation, the left ventricular assist device (LVAD) has significantly improved the quality of life and survival rate of patients with end-stage heart failure. In the automatic detection of electrocardiogram (ECG), the detection of QRS wave groups is the most critical aspect, which affects the correctness and accuracy of subsequent data analysis and processing. The paper used the data from the MIT-BIH database and the data collected from human ECG as the original number of samples for further processing. It processed the data through a high-order finite impulse response (FIR) low-pass filter and Shannon energy algorithm, and added the use of a high-order adaptive median filter algorithm on a field programmable gate array (FPGA) to minimize the noise of the processed real-time data. Finally, the tested ECG R-wave was used to drive the LVAD. After successful simulation by MATLAB and Modelsim software, the scheme of the real-time ECG signal controlling blood pump system was realized on the FPGA platform. The experiment showed that the method proposed could accurately extract the R-wave and control the LVAD to pump blood simultaneously.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] The Relationship Between R-Wave Magnitude and Ventricular Volume During Continuous Left Ventricular Assist Device Assistance: Experimental Study
    Fresiello, Libera
    Trivella, Maria Giovanna
    Di Molfetta, Arianna
    Ferrari, Gianfranco
    Bernini, Fabio
    Meste, Olivier
    ARTIFICIAL ORGANS, 2015, 39 (05) : 446 - 450
  • [2] Research on ECG R-wave Detection Algorithm Based on LabVIEW
    Huang, Danfei
    Zhang, Xiaofeng
    Jiang, Huilin
    Xu, Guozhong
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 709 - 712
  • [3] Effects of denoising strategies on R-wave detection in ECG analysis
    Kozlowski, Michal
    Singh, Sukhpreet
    Ramage, Georgina
    Rodriguez-Villegas, Esther
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 373 - 376
  • [4] Precise detection of R-wave in ECG signal by wavelet transform
    Zhu, HJ
    Qin, SR
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2002, : 661 - 666
  • [5] ECG POOR R-WAVE PROGRESSION
    FEYZ, BB
    ARCHIVES OF INTERNAL MEDICINE, 1987, 147 (07) : 1357 - 1357
  • [6] Adaptive learning and cross training improves R-wave detection in ECG
    Ganapathy, Nagarajan
    Swaminathan, Ramakrishnan
    Deserno, Thomas M.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 200
  • [7] Nonlinear high pass filter for R-wave detection in ECG signal
    Keselbrener, L
    Keselbrener, M
    Akselrod, S
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (05) : 481 - 484
  • [8] Detection of R-wave in ECG based on wavelet transform domain filters
    Dai, Y
    Tang, WY
    Zhang, J
    Li, HP
    Wang, J
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2004, : 837 - 843
  • [9] EXERCISE-INDUCED R-WAVE CHANGE IN THE LEFT PRECORDIAL ECG MAPPING
    UCHIYAMA, I
    MURAYAMA, M
    KAWAHARA, T
    MASHIMA, S
    MURAO, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1980, 44 (08): : 587 - 587
  • [10] R-WAVE AMPLITUDE ON THE ELECTROCARDIOGRAM - CHANGE WITH LEFT-VENTRICULAR VOLUME
    ILSLEY, C
    POOLEWILSON, PA
    RICKARDS, AF
    CLINICAL SCIENCE, 1980, 59 (03) : P21 - P21