Development and evaluation of a new high-TOF-resolution all-digital brain PET system

被引:9
作者
Fang, Lei [1 ]
Zhang, Bo [1 ]
Li, Bingxuan [2 ]
Zhang, Xiangsong [3 ]
Zhou, Xiaoyun [1 ]
Yang, Jigang [4 ]
Li, Ang [1 ]
Shi, Xinchong [3 ]
Liu, Yuqing [2 ]
Kreissl, Michael [5 ,6 ,7 ]
D'Ascenzo, Nicola [1 ,8 ,9 ]
Xiao, Peng [1 ,8 ]
Xie, Qingguo [1 ,8 ,9 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan, Hubei, Peoples R China
[2] Hefei Comprehens Natl Sci Ctr, Inst Artificial Intelligence, Hefei, Anhui, Peoples R China
[3] Sun Yat sen Univ, Affiliated Hosp 1, Dept Nucl Med, Guangzhou, Guangdong, Peoples R China
[4] Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing, Peoples R China
[5] Otto von Guericke Univ, Univ Hosp Magdeburg, Div Nucl Med, Deprtment Radiol & Nucl Med, Magdeburg, Germany
[6] Otto von Guericke Univ, Res Campus STIMULATE, Magdeburg, Germany
[7] German Ctr Neurodegenerat Dis DZNE, Magdeburg, Germany
[8] Univ Sci & Technol China, Dept Elect Engn & Informat Sci, Hefei, Anhui, Peoples R China
[9] Ist Neurol Mediterraneo NEUROMED IRCCS, Dept Innovat Engn & Phys, Pozzilli, Italy
基金
中国国家自然科学基金;
关键词
Brain PET; TOF; 249; ps; MVT sampling method; DIGITIZER;
D O I
10.1088/1361-6560/ad164d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Time-of-flight (TOF) capability and high sensitivity are essential for brain-dedicated positron emission tomography (PET) imaging, as they improve the contrast and the signal-to-noise ratio (SNR) enabling a precise localization of functional mechanisms in the different brain regions. Approach. We present a new brain PET system with transverse and axial field-of-view (FOV) of 320 mm and 255 mm, respectively. The system head is an array of 6 x 6 detection elements, each consisting of a 3.9 x 3.9 x 20 mm3 lutetium-yttrium oxyorthosilicate crystal coupled with a 3.93 x 3.93 mm2 SiPM. The SiPMs analog signals are individually digitized using the multi-voltage threshold (MVT) technology, employing a 1:1:1 coupling configuration. Main results. The brain PET system exhibits a TOF resolution of 249 ps at 5.3 kBq ml-1, an average sensitivity of 22.1 cps kBq-1, and a noise equivalent count rate (NECR) peak of 150.9 kcps at 8.36 kBq ml-1. Furthermore, the mini-Derenzo phantom study demonstrated the system's ability to distinguish rods with a diameter of 2.0 mm. Moreover, incorporating the TOF reconstruction algorithm in an image quality phantom study optimizes the background variability, resulting in reductions ranging from 44% (37 mm) to 75% (10 mm) with comparable contrast. In the human brain imaging study, the SNR improved by a factor of 1.7 with the inclusion of TOF, increasing from 27.07 to 46.05. Time-dynamic human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 2 s per time frame. Significance. The system exhibited a good TOF capability, which is coupled with the high sensitivity and count rate performance based on the MVT digital sampling technique. The developed TOF-enabled brain PET system opens the possibility of precise kinetic brain PET imaging, towards new quantitative predictive brain diagnostics.
引用
收藏
页数:18
相关论文
共 32 条
[11]   Quadratic Programming Time Pickoff Method for Multivoltage Threshold Digitizer in PET [J].
Deng, Zhenzhou ;
Xie, Qingguo .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) :805-813
[12]   The PETcoil project: PET performance evaluation of two detector modules for a second generation RF-penetrable TOF-PET brain dedicated insert for simultaneous PET/MRI [J].
Dong, Qian ;
Chang, Chen-Ming ;
Lee, Brian J. ;
Sacco, Ilaria ;
Sajedi, Salar ;
Adams, Zander ;
Fischer, Peter ;
Levin, Craig S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (08)
[13]   Kinetic evaluation and test-retest reproducibility of [11C]UCB-J, a novel radioligand for positron emission tomography imaging of synaptic vesicle glycoprotein 2A in humans [J].
Finnema, Sjoerd J. ;
Nabulsi, Nabeel B. ;
Mercier, Joel ;
Lin, Shu-fei ;
Chen, Ming-Kai ;
Matuskey, David ;
Gallezot, Jean-Dominique ;
Henry, Shannan ;
Hannestad, Jonas ;
Huang, Yiyun ;
Carson, Richard E. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2018, 38 (11) :2041-2052
[14]   Evolution of PET Detectors and Event Positioning Algorithms Using Monolithic Scintillation Crystals [J].
Gonzalez-Montoro, Andrea ;
Gonzalez, Antonio J. ;
Pourashraf, Shirin ;
Miyaoka, Robert S. ;
Bruyndonckx, Peter ;
Chinn, Garry ;
Pierce, Larry A., II ;
Levin, Craig S. .
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (03) :282-305
[15]   National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner [J].
Grogg, Kira S. ;
Toole, Terrence ;
Ouyang, Jinsong ;
Zhu, Xuping ;
Normandin, Marc D. ;
Li, Quanzheng ;
Johnson, Keith ;
Alpert, Nathaniel M. ;
El Fakhri, Georges .
JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (04) :646-652
[16]  
Guan Y, 2023, Arxiv, DOI arXiv:2310.01885
[17]   Technical performance evaluation of a human brain PET/MRI system [J].
Kolb, Armin ;
Wehrl, Hans F. ;
Hofmann, Matthias ;
Judenhofer, Martin S. ;
Eriksson, Lars ;
Ladebeck, Ralf ;
Lichy, Matthias P. ;
Byars, Larry ;
Michel, Christian ;
Schlemmer, Heinz-Peter ;
Schmand, Matthias ;
Claussen, Claus D. ;
Sossi, Vesna ;
Pichler, Bernd J. .
EUROPEAN RADIOLOGY, 2012, 22 (08) :1776-1788
[18]   Mini EXPLORER II: a prototype high-sensitivity PET/CT scanner for companion animal whole body and human brain scanning [J].
Lv, Yang ;
Lv, Xinyu ;
Liu, Weiping ;
Judenhofer, Martin S. ;
Zwingenberger, Allison ;
Wisner, Erik ;
Berg, Eric ;
McKenney, Sarah ;
Leung, Edwin ;
Spencer, Benjamin A. ;
Cherry, Simon R. ;
Badawi, Ramsey D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (07)
[19]   Evaluation of the performance of a high-resolution time-of-flight PET system dedicated to the head and breast according to NEMA NU 2-2012 standard [J].
Morimoto-Ishikawa, Daisuke ;
Hanaoka, Kohei ;
Watanabe, Shota ;
Yamada, Takahiro ;
Yamakawa, Yoshiyuki ;
Minagawa, Suzuka ;
Takenouchi, Shiho ;
Ohtani, Atsushi ;
Mizuta, Tetsuro ;
Kaida, Hayato ;
Ishii, Kazunari .
EJNMMI PHYSICS, 2022, 9 (01)
[20]   Time of flight in PET revisited [J].
Moses, WW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1325-1330