A Model-Based Markerless Protocol for Clinical Gait Analysis Based on a Single RGB-Depth Camera: Concurrent Validation on Patients With Cerebral Palsy

被引:5
作者
Balta, Diletta [1 ]
Figari, Giulio [2 ]
Paolini, Gabriele [2 ]
Pantzar-Castilla, Evelina [3 ]
Riad, Jacques [4 ,5 ,6 ]
Croce, Ugo Della [7 ]
Cereatti, Andrea [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
[2] GPEM Srl, I-07041 Alghero, Italy
[3] Orebro Univ Hosp, Dept Orthoped, S-70185 Orebro, Sweden
[4] Skaraborg Hosp Skovde, Dept Orthoped, D-40530 Skovde, Sweden
[5] Inst Clin Sci, S-40530 Skovde, Sweden
[6] Univ Gothenburg, Sahlgrenska Acad, S-41390 Gothenburg, Sweden
[7] Univ Sassari, Dept Biomed Sci, I-07100 Sassari, Italy
关键词
Legged locomotion; Gait recognition; Cerebral Palsy; Spatial temporal resolution; Kinematics; Musculoskeletal system; Markerless gait analysis; RGB-depth camera; cerebral palsy; spatial-temporal parameters; sagittal lower-limb joint kinematics; MOTION TRACKING; KINEMATICS; VALIDITY; ACCURACY; PATTERNS; KINECT; RELIABILITY; CALIBRATION; MANAGEMENT; OPENPOSE;
D O I
10.1109/ACCESS.2023.3340622
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Clinical gait analysis is a diagnostic tool often used for identifying and quantifying gait alterations in cerebral palsy (CP) patients. To date, 3D clinical gait analysis protocols based on motion capture systems featuring multiple infrared cameras and retroreflective markers to be attached to the subject's skin are considered the gold standard. However, the need for fully dedicated personnel and space in addition to the inconvenient requirement of multiple markers attached on the patient's body limit their use in the clinical practice. To shorten the time necessary to setup the patient and to limit his/her discomfort motion tracking performed using markerless technologies may offer a promising alternative to marker-based motion capture. This study aims at proposing and validating on 18 CP patients, an original markerless clinical gait analysis protocol based on a single RGB-D camera. Accuracy and reliability of the spatial-temporal parameters and sagittal lower limb joint kinematics were assessed based on a 3D marker-based clinical gait analysis protocol. The smallest percent mean absolute errors were obtained for stride duration (2%), followed by the step and stride length (2.2% and 2.5%, respectively) and by gait speed (3.1%). The average angular offset values between the two protocols were 8 degrees for the ankle, 6 degrees for the knee and 7 degrees for the hip joint. The smallest root mean square error values were found for the knee joint kinematics (3.2 degrees), followed by the hip (3.5 degrees) and the ankle (4.5 degrees). Both protocols showed a good-to-excellent reliability. Thus, this study demonstrated the technical validity of a markerless single-camera protocol for clinical gait analysis in CP population. The dataset containing markerless data from 10 CP patients along with the MATLAB codes have been made available.
引用
收藏
页码:144377 / 144393
页数:17
相关论文
共 67 条
  • [31] Evaluation of Arm Swing Features and Asymmetry during Gait in Parkinson's Disease Using the Azure Kinect Sensor
    Ferraris, Claudia
    Amprimo, Gianluca
    Masi, Giulia
    Vismara, Luca
    Cremascoli, Riccardo
    Sinagra, Serena
    Pettiti, Giuseppe
    Mauro, Alessandro
    Priano, Lorenzo
    [J]. SENSORS, 2022, 22 (16)
  • [32] Monitoring of Gait Parameters in Post-Stroke Individuals: A Feasibility Study Using RGB-D Sensors
    Ferraris, Claudia
    Cimolin, Veronica
    Vismara, Luca
    Votta, Valerio
    Amprimo, Gianluca
    Cremascoli, Riccardo
    Galli, Manuela
    Nerino, Roberto
    Mauro, Alessandro
    Priano, Lorenzo
    [J]. SENSORS, 2021, 21 (17)
  • [33] Goffredo M., 2009, P 4 EUR C INT FED ME
  • [34] A kinematic-geometric model based on ankles? depth trajectory in frontal plane for gait analysis using a single RGB-D camera
    Hatamzadeh, Mehran
    Buse, Laurent
    Chorin, Frederic
    Alliez, Pierre
    Favreau, Jean-Dominique
    Zory, Raphael
    [J]. JOURNAL OF BIOMECHANICS, 2022, 145
  • [35] Joint Depth and Color Camera Calibration with Distortion Correction
    Herrera, Daniel C.
    Kannala, Juho
    Heikkila, Janne
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2012, 34 (10) : 2058 - 2064
  • [36] Concurrent Validity of a Custom Method for Markerless 3D Full-Body Motion Tracking of Children and Young Adults Based on a Single RGB-D Camera
    Hesse, Nikolas
    Baumgartner, Sandra
    Gut, Anja
    van Hedel, Hubertus J. A.
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 1943 - 1951
  • [37] MEASUREMENT OF LOWER-EXTREMITY KINEMATICS DURING LEVEL WALKING
    KADABA, MP
    RAMAKRISHNAN, HK
    WOOTTEN, ME
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) : 383 - 392
  • [38] Using 2D video-based pose estimation for automated prediction of autism spectrum disorders in young children
    Kojovic, Nada
    Natraj, Shreyasvi
    Mohanty, Sharada Prasanna
    Maillart, Thomas
    Schaer, Marie
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [39] A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
    Koo, Terry K.
    Li, Mae Y.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) : 155 - 163
  • [40] Ambulant adults with spastic cerebral palsy: The validity of lower limb joint angle measurements from sagittal video recordings
    Larsen, Kerstin L.
    Maanum, Grethe
    Froslie, Kathrine F.
    Jahnsen, Reidun
    [J]. GAIT & POSTURE, 2012, 35 (02) : 186 - 191