A Model-Based Markerless Protocol for Clinical Gait Analysis Based on a Single RGB-Depth Camera: Concurrent Validation on Patients With Cerebral Palsy

被引:5
作者
Balta, Diletta [1 ]
Figari, Giulio [2 ]
Paolini, Gabriele [2 ]
Pantzar-Castilla, Evelina [3 ]
Riad, Jacques [4 ,5 ,6 ]
Croce, Ugo Della [7 ]
Cereatti, Andrea [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
[2] GPEM Srl, I-07041 Alghero, Italy
[3] Orebro Univ Hosp, Dept Orthoped, S-70185 Orebro, Sweden
[4] Skaraborg Hosp Skovde, Dept Orthoped, D-40530 Skovde, Sweden
[5] Inst Clin Sci, S-40530 Skovde, Sweden
[6] Univ Gothenburg, Sahlgrenska Acad, S-41390 Gothenburg, Sweden
[7] Univ Sassari, Dept Biomed Sci, I-07100 Sassari, Italy
关键词
Legged locomotion; Gait recognition; Cerebral Palsy; Spatial temporal resolution; Kinematics; Musculoskeletal system; Markerless gait analysis; RGB-depth camera; cerebral palsy; spatial-temporal parameters; sagittal lower-limb joint kinematics; MOTION TRACKING; KINEMATICS; VALIDITY; ACCURACY; PATTERNS; KINECT; RELIABILITY; CALIBRATION; MANAGEMENT; OPENPOSE;
D O I
10.1109/ACCESS.2023.3340622
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Clinical gait analysis is a diagnostic tool often used for identifying and quantifying gait alterations in cerebral palsy (CP) patients. To date, 3D clinical gait analysis protocols based on motion capture systems featuring multiple infrared cameras and retroreflective markers to be attached to the subject's skin are considered the gold standard. However, the need for fully dedicated personnel and space in addition to the inconvenient requirement of multiple markers attached on the patient's body limit their use in the clinical practice. To shorten the time necessary to setup the patient and to limit his/her discomfort motion tracking performed using markerless technologies may offer a promising alternative to marker-based motion capture. This study aims at proposing and validating on 18 CP patients, an original markerless clinical gait analysis protocol based on a single RGB-D camera. Accuracy and reliability of the spatial-temporal parameters and sagittal lower limb joint kinematics were assessed based on a 3D marker-based clinical gait analysis protocol. The smallest percent mean absolute errors were obtained for stride duration (2%), followed by the step and stride length (2.2% and 2.5%, respectively) and by gait speed (3.1%). The average angular offset values between the two protocols were 8 degrees for the ankle, 6 degrees for the knee and 7 degrees for the hip joint. The smallest root mean square error values were found for the knee joint kinematics (3.2 degrees), followed by the hip (3.5 degrees) and the ankle (4.5 degrees). Both protocols showed a good-to-excellent reliability. Thus, this study demonstrated the technical validity of a markerless single-camera protocol for clinical gait analysis in CP population. The dataset containing markerless data from 10 CP patients along with the MATLAB codes have been made available.
引用
收藏
页码:144377 / 144393
页数:17
相关论文
共 67 条
  • [1] Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard: A Pilot Study
    Albert, Justin Amadeus
    Owolabi, Victor
    Gebel, Arnd
    Brahms, Clemens Markus
    Granacher, Urs
    Arnrich, Bert
    [J]. SENSORS, 2020, 20 (18) : 1 - 22
  • [2] Amprimo G., 2021, P IT WORKSH ART INT, P70
  • [3] [Anonymous], Move 4D
  • [4] [Anonymous], Theia Markerless
  • [5] A two-dimensional clinical gait analysis protocol based on markerless recordings from a single RGB-Depth camera
    Balta, Diletta
    Salvi, Massimo
    Molinari, Filippo
    Figari, Giulio
    Paolini, Gabriele
    Della Croce, Ugo
    Cereatti, Andrea
    [J]. 2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [6] SIAMOC position paper on gait analysis in clinical practice: General requirements, methods and appropriateness. Results of an Italian consensus conference
    Benedetti, Maria Grazia
    Beghi, Ettore
    De Tanti, Antonio
    Cappozzo, Aurelio
    Basaglia, Nino
    Cutti, Andrea Giovanni
    Cereatti, Andrea
    Stagni, Rita
    Verdini, Federica
    Manca, Mario
    Fantozzi, Silvia
    Mazza, Claudia
    Camomilla, Valentina
    Campanini, Isabella
    Castagna, Anna
    Cavazzuti, Lorenzo
    Del Maestro, Martina
    Della Croce, Ugo
    Gasperi, Marco
    Leo, Tommaso
    Marchi, Pia
    Petrarca, Maurizio
    Piccinini, Luigi
    Rabuffetti, Marco
    Ravaschio, Andrea
    Sawacha, Zimi
    Spolaor, Fabiola
    Tesio, Luigi
    Vannozzi, Giuseppe
    Visintin, Isabella
    Ferrarin, Maurizio
    [J]. GAIT & POSTURE, 2017, 58 : 252 - 260
  • [7] Data management in gait analysis for clinical applications
    Benedetti, MG
    Catani, F
    Leardini, A
    Pignotti, E
    Giannini, S
    [J]. CLINICAL BIOMECHANICS, 1998, 13 (03) : 204 - 215
  • [8] Estimating Orientation Using Magnetic and Inertial Sensors and Different Sensor Fusion Approaches: Accuracy Assessment in Manual and Locomotion Tasks
    Bergamini, Elena
    Ligorio, Gabriele
    Summa, Aurora
    Vannozzi, Giuseppe
    Cappozzo, Aurelio
    Sabatini, Angelo Maria
    [J]. SENSORS, 2014, 14 (10) : 18625 - 18649
  • [9] Accuracy and repeatability of the Microsoft Azure Kinect for clinical measurement of motor function
    Bertram, Johannes
    Krueger, Theresa
    Roehling, Hanna Marie
    Jelusic, Ante
    Mansow-Model, Sebastian
    Schniepp, Roman M.
    Wuehr, Max M.
    Otte, Karen
    [J]. PLOS ONE, 2023, 18 (01):
  • [10] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256