Size-controllable synthesis of large-size spherical 3D covalent organic frameworks as efficient on-line solid-phase extraction sorbents coupled to HPLC

被引:8
|
作者
Chen, Ying [1 ]
He, Qiong [1 ]
Liu, Yuyang [1 ]
Wang, Qiang [1 ]
He, Chiyang [1 ]
Liu, Shaorong [2 ]
机构
[1] Wuhan Text Univ, Coll Chem & Chem Engn, Hubei Key Lab Biomass & Ecodyeing & Finishing, Wuhan 430073, Peoples R China
[2] Univ Oklahoma, Dept Chem & Biochem, Norman, OK 73019 USA
关键词
Three-dimension imine covalent organic; frameworks; Large-size spherical particles; Size-controllable synthesis; Two-step strategy; On-line solid-phase extraction; STATIONARY-PHASE; SEPARATION; REMOVAL; FACILE;
D O I
10.1016/j.aca.2023.342061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Covalent organic frameworks (COFs) have found promising applications in separation fields due to their large surface area and high adsorption capacity, but the exiting COFs can not be directly used as the packing materials of on-line solid-phase extraction (SPE) coupled to HPLC and HPLC because their nano/submicron size or irregular shapes might cause ultrahigh column back pressure and low column efficiency. To synthesize the large-size spherical COFs larger than 3 mu m as sorbents might be able to address these problems, however it is still a great challenge till now. Results: In this work, two large-size spherical 3D COFs (COF-320 and COF-300) were size-controllably synthesized within 10-90 mu m via a two-step strategy. These two spherical COFs showed large surface area, fine crystallinity, good chemical/mechanical stability, and good reproducibility. As an application case, when used as the on-line SPE sorbents coupled to HPLC, the large-size spherical COF-320 displayed high binding capacity for bisphenol F (Qmax of 452.49 mg/g), low column back pressure (6-8 psi at flow rate of 1 mL/min), and good reusability (at least 30 cycles). The developed on-line-SPE-HPLC-UV method presented good analytical performance with enrichment factor of 667 folds, linear range of 1.0-400 ng/mL, limit of detection (LOD, S/N = 3) of 0.3 ng/mL, limit of quantification (LOQ, S/N = 10) of 1.0 ng/mL, and recoveries of 100.3-103.2 % (RSDs of 2.0-3.5 %) and 95.2-97.0 % (RSDs of 4.3-5.6 %) for tap water and lake water samples, respectively. Significance: This is the first case to synthesize the large-size spherical COFs within 10-90 mu m, and this work made it possible to directly use COFs as the filling materials of on-line SPE coupled to HPLC and HPLC. The developed analytical method can be potentially applied to the rapid and sensitive detection of trace bisphenol F in environmental water samples.
引用
收藏
页数:9
相关论文
共 4 条
  • [1] Online solid-phase extraction based on size-controllable spherical covalent organic framework for efficient determination of polybrominated diphenyl ethers in foods
    Lu, Xiao-Fan
    Nan, Zi-Xuan
    Li, Xinyu
    Li, Xuemei
    Liu, Tuanwei
    Ji, Wenhua
    Guo, Dian-Shun
    FOOD CHEMISTRY, 2023, 410
  • [2] Large-size porous spherical 3D covalent organic framework for preconcentration of bisphenol F in water samples and orange juice
    He, Qiong
    Chen, Ying
    Liu, Yuyang
    Wang, Qiang
    He, Chiyang
    Liu, Shaorong
    TALANTA, 2024, 270
  • [3] Aspartic Acid-Assisted Size-Controllable Synthesis of Nanoscale Spherical Covalent Organic Frameworks with Chiral Interfaces for Inhibiting Amyloid-β Fibrillation
    Gao, Kai-Xiang
    Zhou, Zhe
    Yao, Linli
    Wang, Suxiao
    Zhang, Yuexing
    Zou, Qichao
    Ma, Li-Xin
    Wang, Hang-Xing
    ACS APPLIED BIO MATERIALS, 2022, 5 (03) : 1210 - 1221
  • [4] On-line solid-phase extraction of large-volume injections coupled to liquid chromatography-tandem mass spectrometry for the quantitation and confirmation of 14 selected trace organic contaminants in drinking and surface water
    Garcia-Ac, Araceli
    Segura, Pedro A.
    Viglino, Liza
    Furtos, Alexandra
    Gagnon, Christian
    Prevost, Michele
    Sauve, Sebastien
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (48) : 8518 - 8527