Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent

被引:8
作者
Amato, Carlo [1 ,2 ]
Susenburger, Markus [1 ,3 ]
Lehr, Samuel [1 ,3 ]
Kuntz, Jan [1 ]
Gehrke, Nicole [4 ]
Franke, Danielle [4 ]
Thuering, Thomas [5 ]
Briel, Andreas [4 ]
Broennimann, Christian [5 ]
Kachelriess, Marc [1 ,2 ]
Sawall, Stefan [1 ,2 ]
机构
[1] German Canc Res Ctr, Div Xray Imaging & Computed Tomog, D-69120 Heidelberg, Germany
[2] Ruprecht Karls Univ Heidelberg, Med Fac, D-69120 Heidelberg, Germany
[3] Ruprecht Karls Univ Heidelberg, Dept Phys & Astron, D-69120 Heidelberg, Germany
[4] nanoPET Pharma GmbH, D-10115 Berlin, Germany
[5] DECTRIS Ltd, CH-5405 Baden, Switzerland
关键词
photon-counting computed-tomography; micro-CT; high-Z nanoparticles; multi-contrast agent protocol; material decomposition; COMPUTED-TOMOGRAPHY;
D O I
10.1088/1361-6560/acdb42
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives. To characterize for the first time in vivo a novel bismuth-based nanoparticular contrast agent developed for preclinical applications. Then, to design and test in vivo a multi-contrast protocol for functional cardiac imaging using the new bismuth nanoparticles and a well-established iodine-based contrast agent. Approach. A micro-computed tomography scanner was assembled and equipped with a photon-counting detector. Five mice were administered with the bismuth-based contrast agent and systematically scanned over 5 h to quantify the contrast enhancement in relevant organs of interest. Subsequently, the multi-contrast agent protocol was tested on three mice. Material decomposition was performed on the acquired spectral data to quantify the concentration of bismuth and iodine in multiple structures, e.g. the myocardium and vasculature. Main results. In the vasculature, the bismuth agent provides a peak enhancement of 1100 HU and a half-life of about 260 min. After the injection, it accumulates in the liver, spleen and intestinal wall reaching a CT value of 440 HU about 5 h post injection. Phantom measurements showed that the bismuth provides more contrast enhancement than iodine for a variety of tube voltages. The multi-contrast protocol for cardiac imaging successfully allowed the simultaneous decomposition of the vasculature, the brown adipose tissue and the myocardium. Significance. The new bismuth-based contrast agent was proven to have a long circulation time suitable for preclinical applications and to provide more contrast than iodine agents. The proposed multi-contrast protocol resulted in a new tool for cardiac functional imaging. Furthermore, thanks to the contrast enhancement provided in the intestinal wall, the novel contrast agent may be used to develop further multi contrast agent protocols for abdominal and oncological imaging.
引用
收藏
页数:10
相关论文
共 31 条
[1]   Potential of contrast agents based on high-Z elements for contrast-enhanced photon-counting computed tomography [J].
Amato, Carlo ;
Klein, Laura ;
Wehrse, Eckhard ;
Rotkopf, Lukas T. ;
Sawall, Stefan ;
Maier, Joscha ;
Ziener, Christian H. ;
Schlemmer, Heinz-Peter ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2020, 47 (12) :6179-6190
[2]   AuNP-DG: Deoxyglucose-Labeled Gold Nanoparticles as X-ray Computed Tomography Contrast Agents for Cancer Imaging [J].
Aydogan, Bulent ;
Li, Ji ;
Rajh, Tijana ;
Chaudhary, Ahmed ;
Chmura, Steven J. ;
Pelizzari, Charles ;
Wietholt, Christian ;
Kurtoglu, Metin ;
Redmond, Peter .
MOLECULAR IMAGING AND BIOLOGY, 2010, 12 (05) :463-467
[3]   Functional imaging of tumor vasculature using iodine and gadolinium-based nanoparticle contrast agents: a comparison of spectral micro-CT using energy integrating and photon counting detectors [J].
Badea, C. T. ;
Clark, D. P. ;
Holbrook, M. ;
Srivastava, M. ;
Mowery, Y. ;
Ghaghada, K. B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06)
[4]   Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging [J].
Ballabriga, R. ;
Alozy, J. ;
Campbell, M. ;
Frojdh, E. ;
Heijne, E. H. M. ;
Koenig, T. ;
Llopart, X. ;
Marchal, J. ;
Pennicard, D. ;
Poikela, T. ;
Tlustos, L. ;
Valerio, P. ;
Wong, W. ;
Zuber, M. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[5]   Dual-Energy Computed Tomography Imaging of Atherosclerotic Plaques in a Mouse Model Using a Liposomal-Iodine Nanoparticle Contrast Agent [J].
Bhavane, Rohan ;
Badea, Cristian ;
Ghaghada, Ketan B. ;
Clark, Darin ;
Vela, Deborah ;
Moturu, Anoosha ;
Annapragada, Akshaya ;
Johnson, G. Allan ;
Willerson, James T. ;
Annapragada, Ananth .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (02) :285-294
[6]   IBEX: Versatile Readout ASIC With Spectral Imaging Capability and High Count Rate Capability [J].
Bochenek, M. ;
Bottinelli, S. ;
Broennimann, Ch. ;
Livi, P. ;
Loeliger, T. ;
Radicci, V. ;
Schnyder, R. ;
Zambon, P. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (06) :1285-1291
[7]   Cardiorespiratory motion-compensated micro-CT image reconstruction using an artifact model-based motion estimation [J].
Brehm, Marcus ;
Sawall, Stefan ;
Maier, Joscha ;
Sauppe, Sebastian ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2015, 42 (04) :1948-1958
[8]   Artifact-resistant motion estimation with a patient-specific artifact model for motion-compensated cone-beam CT [J].
Brehm, Marcus ;
Paysan, Pascal ;
Oelhafen, Markus ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2013, 40 (10)
[9]   Advances in micro-CT imaging of small animals [J].
Clark, D. P. ;
Badea, C. T. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 :175-192
[10]   Micro-CT of rodents: State-of-the-art and future perspectives [J].
Clark, D. P. ;
Badea, C. T. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06) :619-634