An Electrochemical Screen-Printed Sensor Based on Gold-Nanoparticle-Decorated Reduced Graphene Oxide-Carbon Nanotubes Composites for the Determination of 17-β Estradiol

被引:25
作者
Musa, Auwal M. [1 ]
Kiely, Janice [2 ]
Luxton, Richard [2 ]
Honeychurch, Kevin C. [1 ,2 ]
机构
[1] Univ West England, Inst Biosensing Technol IBST, Bristol BS16 1QY, Gloucestershire, England
[2] Univ West England, Ctr Res Biosci CRIB, Sch Appl Sci, Bristol BS16 1QY, Gloucestershire, England
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 04期
关键词
estradiol; gold nanoparticles; graphene oxide; carbon nanotubes; disposable screen-printed electrodes; MOLECULARLY IMPRINTED POLYMER; GLASSY-CARBON; GREEN REDUCTION; DIFFUSION-COEFFICIENTS; SENSITIVE DETECTION; ELECTRODE; WATER; 17-BETA-ESTRADIOL; VOLTAMMETRY; BEHAVIOR;
D O I
10.3390/bios13040491
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a screen-printed electrode (SPE) modified with gold-nanoparticle-decorated reduced graphene oxide-carbon nanotubes (rGO-AuNPs/CNT/SPE) was used for the determination of estradiol (E2). The AuNPs were produced through an eco-friendly method utilising plant extract, eliminating the need for severe chemicals, and remove the requirements of sophisticated fabrication methods and tedious procedures. In addition, rGO-AuNP serves as a dispersant for the CNT to improve the dispersion stability of CNTs. The composite material, rGO-AuNPs/CNT, underwent characterisation through scanning electron microscopy (SEM), ultraviolet-visible absorption spectroscopy (UV-vis), Fourier-transform infrared (FTIR) spectroscopy, and atomic force microscopy (AFM). The electrochemical performance of the modified SPE for estradiol oxidation was characterised using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The rGO-AuNPs/CNT/SPE exhibited a notable improvement compared to bare/SPE and GO-CNT/SPE, as evidenced by the relative peak currents. Additionally, we employed a baseline correction algorithm to accurately adjust the sensor response while eliminating extraneous background components that are typically present in voltammetric experiments. The optimised estradiol sensor offers linear sensitivity from 0.05-1.00 mu M, with a detection limit of 3 nM based on three times the standard deviation (3 delta). Notably, this sensing approach yields stable, repeatable, and reproducible outcomes. Assessment of drinking water samples indicated an average recovery rate of 97.5% for samples enriched with E2 at concentrations as low as 0.5 mu M%, accompanied by only a modest coefficient of variation (%CV) value of 2.7%.
引用
收藏
页数:17
相关论文
共 87 条
[1]   Honeycomb Carbon: A Review of Graphene [J].
Allen, Matthew J. ;
Tung, Vincent C. ;
Kaner, Richard B. .
CHEMICAL REVIEWS, 2010, 110 (01) :132-145
[2]   NanoMIP based optical sensor for pharmaceuticals monitoring [J].
Altintas, Zeynep ;
Guerreiro, Antonio ;
Piletsky, Sergey A. ;
Tothill, Ibtisam E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 :305-313
[3]   Electrochemically Exfoliated Graphene and Graphene Oxide for Energy Storage and Electrochemistry Applications [J].
Ambrosi, Adriano ;
Pumera, Martin .
CHEMISTRY-A EUROPEAN JOURNAL, 2016, 22 (01) :153-159
[4]   Analytical methodology for the electro-catalytic determination of estradiol and progesterone based on graphene quantum dots and poly(sulfosalicylic acid) co-modified electrode [J].
Arvand, Majid ;
Hemmati, Shiva .
TALANTA, 2017, 174 :243-255
[5]   The green reduction of graphene oxide [J].
Aunkor, M. T. H. ;
Mahbubul, I. M. ;
Saidur, R. ;
Metselaar, H. S. C. .
RSC ADVANCES, 2016, 6 (33) :27807-27828
[6]   Graphene: synthesis and applications [J].
Avouris, Phaedon ;
Dimitrakopoulos, Christos .
MATERIALS TODAY, 2012, 15 (03) :86-97
[7]  
Azzaroni O, 2011, FUNCTIONAL POLYMER FILMS, VOLS 1 AND 2, P809
[8]  
Balandin AA, 2011, NAT MATER, V10, P569, DOI [10.1038/nmat3064, 10.1038/NMAT3064]
[9]   Determination of estrogenic endocrine disruptors in water at sub-ng L-1 levels in compliance with Decision 2015/495/EU using offline-online solid phase extraction concentration coupled with high performance liquid chromatography-tandem mass spectrometry [J].
Barreca, Salvatore ;
Busetto, Maddalena ;
Colzani, Luisa ;
Clerici, Laura ;
Daverio, Daniela ;
Dellavedova, Pierluisa ;
Balzamo, Stefania ;
Calabretta, Elisa ;
Ubaldi, Vanessa .
MICROCHEMICAL JOURNAL, 2019, 147 :1186-1191
[10]   Analysis of 17-β-estradiol and 17-α-ethinylestradiol in biological and environmental matrices - A review [J].
Barreiros, Luisa ;
Queiroz, Joana F. ;
Magalhaes, Luis M. ;
Silva, Adrian M. T. ;
Segundo, Marcela A. .
MICROCHEMICAL JOURNAL, 2016, 126 :243-262