Evaluation of Trabecular Microstructure of Cancellous Bone Using Quarter-Detector Computed Tomography

被引:1
|
作者
Hasegawa, Hiroaki [1 ]
Nango, Nobuhito [2 ]
Machida, Masafumi [3 ]
机构
[1] Int Univ Hlth & Welf, Dept Radiol Sci, Narita 2868686, Japan
[2] Ratoc Syst Engn Co Ltd, Tokyo 1620801, Japan
[3] Hakujikai Mem Hosp, Dept Orthoped Surg, Tokyo 1230864, Japan
关键词
osteoporosis; quarter-detector computed tomography; micro-computed tomography; trabecular microstructure; cancellous bone; HIGH-RESOLUTION CT; MINERAL DENSITY; MICROARCHITECTURE; THICKNESS; WOMEN; QUANTIFICATION; PREMENOPAUSAL; MONOTHERAPY; MECHANISMS; PATTERN;
D O I
10.3390/diagnostics13071240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quarter-detector computed tomography (QDCT) is an ultra-high-spatial-resolution imaging technique. This study aimed to verify the validity of trabecular structure evaluation using a QDCT scanner in the diagnosis of osteoporosis. We used a cancellous bone specimen image of the second lumbar vertebrae of an adult male with moderate osteoporosis. To obtain QDCT images, we created a three-dimensional model from micro-CT images of the specimen. Statistical analysis was performed on the relationship between micro-CT and QDCT imaging modalities. The differences between micro-CT and QDCT were assessed based on their significance with respect to the calculated mean measurements using the Mann-Whitney test. Single regression analysis was performed using linear regression, with micro-CT and QDCT as the explanatory and objective variables, respectively, to determine the relationship of the measured values between the two modalities. By applying the necessary correction to the micro-CT measured values, it is possible to perform an analysis equivalent to micro-CT, which offers higher spatial resolution than QDCT. We found evidence that if QDCT can be used, trabecular structure evaluation may contribute to image diagnosis to evaluate practical bone fragility.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Micro-computed tomography and compressive characterization of trabecular bone
    Catarina Vale, A.
    Pereira, M. F. C.
    Mauricio, A.
    Amaral, P.
    Rosa, L. G.
    Lopes, A.
    Rodrigues, A.
    Caetano-Lopes, J.
    Vidal, B.
    Monteiro, J.
    Fonseca, J. E.
    Canhao, H.
    Fatima Vaz, M.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 438 : 199 - 205
  • [32] Detection of trabecular bone microdamage by micro-computed tomography
    Wang, Xiang
    Masse, Daniel B.
    Leng, Huijie
    Hess, Kevin P.
    Ross, Ryan D.
    Roeder, Ryan K.
    Niebur, Glen L.
    JOURNAL OF BIOMECHANICS, 2007, 40 (15) : 3397 - 3403
  • [33] Micro-computed tomography evaluation of trabecular bone structure on loaded mice tail vertebrae
    Issever, AS
    Walsh, A
    Lu, Y
    Burghardt, A
    Lotz, JC
    Majumdar, S
    SPINE, 2003, 28 (02) : 123 - 128
  • [34] The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography
    Kang, Se-Ryong
    Bok, Sung-Chul
    Choi, Soon-Chul
    Lee, Sam-Sun
    Heo, Min-Suk
    Huh, Kyung-Hoe
    Kim, Tae-Il
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (02) : 116 - 127
  • [35] Predicting the permeability of trabecular bone by micro-computed tomography and finite element modeling
    Sandino, Clara
    Kroliczek, Paul
    McErlain, David D.
    Boyd, Steven K.
    JOURNAL OF BIOMECHANICS, 2014, 47 (12) : 3129 - 3134
  • [36] Three-dimensional multifractal analysis of trabecular bone under clinical computed tomography
    Baravalle, Rodrigo
    Thomsen, Felix
    Delrieux, Claudio
    Lu, Yongtao
    Gomez, Juan Carlos
    Stosic, Borko
    Stosic, Tatijana
    MEDICAL PHYSICS, 2017, 44 (12) : 6404 - 6412
  • [37] Assessment of trabecular and cortical architecture and mechanical competence of bone by high-resolution peripheral computed tomography: comparison with transiliac bone biopsy
    Cohen, A.
    Dempster, D. W.
    Mueller, R.
    Guo, X. E.
    Nickolas, T. L.
    Liu, X. S.
    Zhang, X. H.
    Wirth, A. J.
    van Lenthe, G. H.
    Kohler, T.
    McMahon, D. J.
    Zhou, H.
    Rubin, M. R.
    Bilezikian, J. P.
    Lappe, J. M.
    Recker, R. R.
    Shane, E.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 (02) : 263 - 273
  • [38] Morphometric Analysis of Mandibular Trabecular Bone Using Cone Beam Computed Tomography: An In Vitro Study
    Naitoh, Munetaka
    Aimiya, Hidetoshi
    Hirukawa, Akiko
    Ariji, Eiichiro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1093 - 1098
  • [39] Trabecular Bone Morphological Analysis for Preclinical Osteoporosis Application Using Micro Computed Tomography Scanner
    Jin, David Shih-Chun
    Chu, Chien-Hao
    Chen, Jyh-Cheng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (01) : 96 - 104
  • [40] Trabecular Bone Morphological Analysis for Preclinical Osteoporosis Application Using Micro Computed Tomography Scanner
    David Shih-Chun Jin
    Chien-Hao Chu
    Jyh-Cheng Chen
    Journal of Medical and Biological Engineering, 2016, 36 : 96 - 104