Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials

被引:0
|
作者
Tariq, Muhammad A. [1 ,3 ]
Ali, Uzair [1 ]
Uddin, Qazi S. [2 ]
Altaf, Zahabia [2 ]
Mohiuddin, Ashar [1 ]
机构
[1] Dow Univ Hlth Sci, Dow Univ Hosp, Dept Surg, Karachi, Pakistan
[2] Dow Univ Hlth Sci, Dow Med Coll, Dept Surg, Karachi, Pakistan
[3] Dow Univ Hosp, Dept Surg, Gulzar e Hijri Scheme 33,Suparco Rd, Karachi 74200, Pakistan
关键词
distal radius fracture; Kirschner wire; meta-analysis; volar locking plating; DORSALLY DISPLACED FRACTURE; INTERNAL-FIXATION; PERCUTANEOUS FIXATION; FUNCTIONAL OUTCOMES; SURGICAL-TREATMENT; EXTERNAL FIXATION; OPEN REDUCTION; HAND; REHABILITATION; COMPLICATIONS;
D O I
10.1055/s-0043-1768235
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective This study aims to compare the outcomes of volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of unstable distal radius fractures. Methods We systematically searched multiple databases, including MEDLINE, EMBASE, Cochrane Central till January 2022 for randomized controlled trials (RCTs) that met eligibility criteria. Following outcomes were evaluated at 6-week, 3-, 6-, and 12-month follow-up period: Disabilities of the Arm, Shoulder, and Hand (DASH) score, Patient Rated Wrist Evaluation (PRWE) score, grip strength, range of motion, and complication incidence. Meta-analysis was performed using random effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval. Results Fourteen RCTs with 1,450 participants met the inclusion criteria. DASH scores were significantly better for VLP fixation at 6th week (MD = 19.02; p < 0.001), 3rd (MD = 10.79; p < 0.001), 6th (MD= 7.78; p < 0.001), and 12th month (MD = 2.94; p < 0.001) postoperation. At 3-month follow-up period, VLP treatment exhibited better grip strength (MD = - 10.32; p < 0.001) and PRWE scores (MD = 8.78; p < 0.001). There was a statistically significant early advantage in flexion, extension, pronation, supination, radial deviation, and ulnar deviation in the VLP group at 6-week follow-up, but at 1-year follow-up only significantly better extension was observed. At 1 year, radiographic outcomes were similar except for volar tilt favoring VLP fixation (p < 0.001). Superficial infections were more common in patients treated with K-wire (RR = 2.89; p = 0.001), but there was no difference in total complications or reoperation rates (p > 0.05). Conclusion This meta-analysis suggests that VLP fixation and K-wire fixation are both effective procedures, but existing literature does not provide sufficient evidence to demonstrate the superiority of either method. Although VLP fixation improves DASH score, extension and volar tilt at 12-month follow-up, the difference is small and unlikely to be noticeable to the patients.
引用
收藏
页码:469 / 480
页数:12
相关论文
共 50 条
  • [21] Locking plate versus external fixation for type C distal radius fractures: A meta-analysis of randomized controlled trials
    Wang, Dong
    Shan, Lei
    Zhou, Jun-Lin
    CHINESE JOURNAL OF TRAUMATOLOGY, 2018, 21 (02) : 113 - 117
  • [22] Volar Locking Plate versus Closed Reduction and Immobilization for Distal Radius Fracture in the Elderly: Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Latypov, Niyaz
    Golubev, Igor
    Borisova, Alyona
    JOURNAL OF WRIST SURGERY, 2024, 13 (06) : 559 - 571
  • [23] Volar locking plate versus external fixation in distal radius fractures: A meta-analysis
    Maccagnano, Giuseppe
    Noia, Giovanni
    Vicenti, Giovanni
    Baglioni, Marco
    Masciale, Maria Rosa
    Cassano, Giuseppe Danilo
    Vitiello, Raffaele
    Moretti, Biagio
    Pesce, Vito
    ORTHOPEDIC REVIEWS, 2021, 13 (01)
  • [24] External fixation versus open reduction with plate fixation for distal radius fractures: A meta-analysis of randomised controlled trials
    Esposito, John
    Schemitsch, Emil H.
    Saccone, Michel
    Sternheim, Amir
    Kuzyk, Paul R. T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 409 - 416
  • [25] Effectiveness of early versus delayed motion in patients with distal radius fracture treated with volar locking plate: A systematic review and meta-analysis
    Gutierrez-Espinoza, H.
    Araya-Quintanilla, F.
    Olguin-Huerta, C.
    Gutierrez-Monclus, R.
    Jorquera-Aguilera, R.
    Mathoulin, C.
    HAND SURGERY & REHABILITATION, 2021, 40 (01) : 6 - 16
  • [26] Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis
    Walenkamp, Monique M. J.
    Bentohami, Abdelali
    Beerekamp, M. Suzan H.
    Peters, Rolf W.
    van der Heiden, Remy
    Goslings, J. Carel
    Schep, Niels W. L.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2013, 8 (02) : 67 - 75
  • [27] Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius
    Khan, Naveed Ullah
    Khan, Abdul Qadir
    Jameel, Muhammad
    Yaqoob, Hafiz Muhammad
    Khan, Zeeshan
    Bajwa, Mubashar Ahmad
    RAWAL MEDICAL JOURNAL, 2020, 45 (01): : 107 - 110
  • [28] Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation
    Erhart, S.
    Toth, S.
    Kaiser, P.
    Kastenberger, T.
    Deml, C.
    Arora, R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (06) : 879 - 885
  • [29] Complications following dorsal versus volar plate fixation of distal radius fracture: A meta-analysis
    Wei, Jie
    Yang, Tu-Bao
    Luo, Wei
    Qin, Jia-Bi
    Kong, Fan-Jing
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (02) : 265 - 275
  • [30] Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
    Shinohara, Takaaki
    Hirata, Hitoshi
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2017, 79 (04): : 551 - 557