Experimental and numerical investigation on the effect of concrete infill in pultruded GFRP CHS intermediate and long columns under axial and eccentric compression

被引:5
作者
Higgoda, Thumitha Mandula [1 ]
Elchalakani, Mohamed [1 ]
Kimiaei, Mehrdad [2 ]
Wittek, Adam [3 ]
Yang, Bo [4 ]
机构
[1] Univ Western Australia, Dept Civil Environm & Min Engn, 35 Stirling Highway, Perth, WA 6009, Australia
[2] Univ Western Australia, Oceans Grad Sch, 35 Stirling Highway, Perth, WA 6009, Australia
[3] Univ Western Australia, Dept Mech Engn, Intelligent Syst Med Lab, 35 Stirling Highway, Perth, WA 6009, Australia
[4] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
关键词
Localised hoop rupture; Longitudinal splitting; Concrete filled; GFRP; Pultruded; FLEXURAL BEHAVIOR; COMPOSITE TUBES; FRP TUBES; SQUARE; STRENGTH; MODEL;
D O I
10.1016/j.istruc.2023.03.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents an experimental investigation of concrete-filled (CFFT) pultruded glass fibre-reinforced (GFRP) circular tubular columns under concentric and eccentric loading. The effective slenderness ratios of the CFFTs were 33, 44 and 55 and were tested under two different eccentricities of 28.5 mm and 57 mm. The failure modes observed for the CFFTs include localised hoop rupture and longitudinal splitting of the GFRP tube with concrete crushing. The axial load-carrying capacities of the CFFTs decreased with increasing eccentricity and slenderness. The strength and the ductility of the CFFTs were compared with their circular hollow section (CHS) counterparts tested in a previous study. A P-M interaction curve was developed, and its applicability was assessed against the experimental results for different slenderness ratios. The ultimate axial load and the locus and nature of the failure modes of CFFTs predicted from the developed finite element models were in good agreement with the experimental observations. The extent of damage of the GFRP tube in the CFFTs was compared to the damage of the GFRP CHS columns using FE analysis employing the Hashin damage material model for GFRP tube.
引用
收藏
页码:137 / 157
页数:21
相关论文
共 47 条
[1]   Analytical investigation on the load-moment interaction behavior of the FRP reinforced geopolymer concrete filled FRP tube circular columns [J].
Ahmad, Junaid ;
Ali, Shehroze ;
Yu, Tao ;
Sheikh, M. Neaz ;
Hadi, Muhammad N. S. .
JOURNAL OF BUILDING ENGINEERING, 2021, 42
[2]   Structural applications of fibre reinforced polymer (FRP) composite tubes: A review of columns members [J].
Al-saadi, Ali Umran ;
Aravinthan, Thiru ;
Lokuge, Weena .
COMPOSITE STRUCTURES, 2018, 204 :513-524
[3]   Mechanical models for predicting the strength and stiffness of a beam-to-column adhesively-bonded connection between pultruded profiles [J].
Ascione, Francesco ;
Granata, Luigi .
STRUCTURES, 2022, 43 :493-507
[4]   On the flexural behaviour of GFRP beams obtained by bonding simple panels: An experimental investigation [J].
Ascione, Francesco ;
Mancusi, Geminiano ;
Spadea, Saverio ;
Lamberti, Marco ;
Lebon, Frederic ;
Maurel-Pantel, Aurelien .
COMPOSITE STRUCTURES, 2015, 131 :55-65
[5]  
ASTM International, D2344 STAND TEST MET
[6]  
ASTM International, D695 STAND TEST METH
[7]  
ASTM International, D3171 STAND TEST MET
[8]  
ASTM International, D2290 STAND TEST MET
[9]  
ASTM International,, D3039 STAND TEST MET
[10]   Fiber-reinforced polymer composites for construction-state-of-the-art review [J].
Bakis, CE ;
Bank, LC ;
Brown, VL ;
Cosenza, E ;
Davalos, JF ;
Lesko, JJ ;
Machida, A ;
Rizkalla, SH ;
Triantafillou, TC .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2002, 6 (02) :73-87