Safety-aware robotic steering of a flexible endoscope for nasotracheal intubation

被引:5
作者
Deng, Zhen [1 ,2 ]
Jiang, Peijie [3 ]
Guo, Yuxin [2 ]
Zhang, Shengzhan [2 ]
Hu, Ying [3 ]
Zheng, Xiaochun [1 ]
He, Bingwei [2 ]
机构
[1] Shengli Clin Med Coll Fujian Med Univ, Fujian Prov Hosp, Dept Anesthesiol, Fuzhou 350108, Peoples R China
[2] Fuzhou Univ, Dept Mech Engn & Automation, Fuzhou 350108, Peoples R China
[3] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Robotic endoscopy; Endoscopic image processing; Depth estimation; Visual feedback control; Nasotracheal intubation; TRACKING; NAVIGATION;
D O I
10.1016/j.bspc.2022.104504
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automation in robotic endoscopy surgery is an important but challenging research topic. The flexible deformation of the endoscope makes it difficult for surgeons to steer it, especially in a narrow workspace. The safety of endoscope steering has been a major concern in a robotic endoscope. This study presents a safety-aware control framework to enable a robotic endotracheal intubation system (RNIS) to automatically steer the flexible endoscope during nasotracheal intubation (NTI). With the endoscopic image as feedback, we used the fusion of image intensity and optical flow measurements to detect the lumen center. A velocity-based orientation controller is designed to adjust the orientation of the endoscope tip to track the lumen center. To ensure surgical safety, the relative depth from the endoscope tip to the lumen surface is calculated from endoscopic images. With the relative depth as feedback, the feed motion of the endoscope is controlled to prevent the collision between the endoscope tip and its surrounding tissue. The position and orientation of the endoscope tip can be adjusted by the RNIS during NTI. Finally, extensive experiments based on a training manikin were performed. The results indicate that the proposed control framework enables the RNIS to successfully steer the flexible endoscope along the upper respiratory tract with high safety. The performance of lumen center detection is good according to the annotation of experienced users.
引用
收藏
页数:9
相关论文
共 33 条
[1]  
Bell CS, 2014, IEEE INT CONF ROBOT, P5386, DOI 10.1109/ICRA.2014.6907651
[2]   REALITI: A Robotic Endoscope Automated via Laryngeal Imaging for Tracheal Intubation [J].
Boehler, Quentin ;
Gage, David S. ;
Hofmann, Phyllis ;
Gehring, Alexandra ;
Chautems, Christophe ;
Spahn, Donat R. ;
Biro, Peter ;
Nelson, Bradley J. .
IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2020, 2 (02) :157-164
[3]  
Bouguet J-Y., 1999, Pyramidal implementation of the lucas kanade feature tracker
[4]  
Choi Y.F., 2003, HONG KONG J EMERG ME, V10, P138
[5]   Robust feature tracking on the beating heart for a robotic-guided endoscope [J].
Elhawary, Haytham ;
Popovic, Aleksandra .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (04) :459-468
[6]  
Fleet D, 2006, HANDBOOK OF MATHEMATICAL MODELS IN COMPUTER VISION, P239
[7]   Multi-View Stereo: A Tutorial [J].
Furukawa, Yasutaka ;
Hernandez, Carlos .
FOUNDATIONS AND TRENDS IN COMPUTER GRAPHICS AND VISION, 2013, 9 (1-2) :1-148
[8]   First robotic tracheal intubations in humans using the Kepler intubation system [J].
Hemmerling, T. M. ;
Taddei, R. ;
Wehbe, M. ;
Zaouter, C. ;
Cyr, S. ;
Morse, J. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (06) :1011-1016
[9]   Navigation strategy for robotic soft endoscope intervention [J].
Jiang, Wei ;
Zhou, Yuanyuan ;
Wang, Chongyang ;
Peng, Lihua ;
Yang, Yunsheng ;
Liu, Hao .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (02)
[10]   Prediction of the Location of the Glottis in Laryngeal Images by Using a Novel Deep-Learning Algorithm [J].
Kim, Jong Soo ;
Cho, Yongil ;
Lim, Tae Ho .
IEEE ACCESS, 2019, 7 (79545-79554) :79545-79554