External cardioversion of atrial fibrillation and flutter in patients with cardiac implantable electrical devices

被引:3
作者
Elgaard, Anders Fyhn [1 ,2 ]
Dinesen, Pia Thisted [3 ]
Riahi, Sam [1 ,2 ]
Hansen, John [4 ]
Lundbye-Christensen, Soren [5 ]
Thogersen, Anna Margrethe [1 ]
Larsen, Jacob Moesgaard [1 ,2 ]
机构
[1] Aalborg Univ Hosp, Dept Cardiol, Sdr Skovvej 15, DK-9000 Aalborg, Denmark
[2] Aalborg Univ, Dept Clin Med, Aalborg, Denmark
[3] Aalborg Univ Hosp, Dept Anaesthesia & Intens Care Med, Aalborg, Denmark
[4] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[5] Aalborg Univ Hosp, Dept Res Data & Stat, Aalborg, Denmark
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2023年 / 46卷 / 02期
关键词
CIED; defibrillation; device complication; external cardioversion; ICD; interrogation; Pacemaker; PACEMAKER; SHOCK; BURDEN;
D O I
10.1111/pace.14616
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrial fibrillation and flutter are often treated with external electrical cardioversion (ECV) in patients with potentially electrically sensitive cardiovascular implantable electronic devices (CIED). Long-term follow-up data on contemporary CIED undergoing ECV is sparse. The aim is to investigate shock-related complications and impact on CIEDs. MethodsAll ECV procedures from 2010 to 2020 in patients with CIED performed at a tertiary university hospital were identified in the Danish National Patient Registry. Changes in device measurements after ECV were retrospectively studied and procedure-related complications were identified by review of medical records. ResultsWe analyzed 763 ECV procedures in 372 patients, median device implant time 1.9 years. The mean age of patients was 69.9 +/- 9.9 years of which 73.4% were men. We identified two cases of device programming changes and four cases of premature battery depletion (<= 3 years after device implant). Minor changes in device measurements were found for impedances, sensing, and pacing thresholds. No patients died due to ECV-related device dysfunctions within the first 12 months after cardioversions. ConclusionExternal cardioversion in patients with contemporary pacemakers and implantable cardioverter-defibrillators seems safe in the majority of patients. Clinically important changes in device function following cardioversion were rarely observed but may be critical for device function. In an observational study, causality between cardioversion and device dysfunction cannot be established. For patient safety, we suggest that routine device interrogation after cardioversion still should be part of standard care.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 22 条
[1]   Positive predictive value of cardiac examination, procedure and surgery codes in the Danish National Patient Registry: a population-based validation study [J].
Adelborg, Kasper ;
Sundboll, Jens ;
Munch, Troels ;
Froslev, Trine ;
Sorensen, Henrik Toft ;
Botker, Hans Erik ;
Schmidt, Morten .
BMJ OPEN, 2016, 6 (12)
[2]   TRANSTHORACIC DC SHOCK MAY REPRESENT A SERIOUS HAZARD IN PACEMAKER DEPENDENT PATIENTS [J].
ALTAMURA, G ;
BIANCONI, L ;
LOBIANCO, F ;
TOSCANO, S ;
AMMIRATI, F ;
PANDOZI, C ;
CASTRO, A ;
CARDINALE, M ;
MENNUNI, M ;
SANTINI, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (01) :194-198
[3]  
Annamaria Martino, 2008, Indian Pacing Electrophysiol J, V8, P222
[4]   Atrial fibrillation: Profile and burden of an evolving epidemic in the 21st century [J].
Ball, Jocasta ;
Carrington, Melinda J. ;
McMurray, John J. V. ;
Stewart, Simon .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) :1807-1824
[5]  
Barold SSFM., 1991, CARDIAC PACING ELECT, pS608
[6]   Cardioversion of atrial fibrillation and atrial flutter revisited: current evidence and practical guidance for a common procedure [J].
Brandes, Axel ;
Crijns, Harry J. G. M. ;
Rienstra, Michiel ;
Kirchhof, Paulus ;
Grove, Erik L. ;
Pedersen, Kenneth Bruun ;
Van Gelder, Isabelle C. .
EUROPACE, 2020, 22 (08) :1149-1161
[7]  
Camm AJ, 2010, EUR HEART J, V31, P2369, DOI [10.1093/eurheartj/ehq278, 10.1093/europace/euq350]
[8]   Worldwide Epidemiology of Atrial Fibrillation A Global Burden of Disease 2010 Study [J].
Chugh, Sumeet S. ;
Havmoeller, Rasmus ;
Narayanan, Kumar ;
Singh, David ;
Rienstra, Michiel ;
Benjamin, Emelia J. ;
Gillum, Richard F. ;
Kim, Young-Hoon ;
McAnulty, John H. ;
Zheng, Zhi-Jie ;
Forouzanfar, Mohammad H. ;
Naghavi, Mohsen ;
Mensah, George A. ;
Ezzati, Majid ;
Murray, Christopher J. L. .
CIRCULATION, 2014, 129 (08) :837-847
[9]   2011 ACCF/AHA/HRS Focused Updates Incorporated Into the ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines 2006 WRITING COMMITTEE MEMBERS Developed in partnership with the European Society of Cardiology and in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, Davis S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Kay, G. Neal ;
Le Huezey, Jean-Yves ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, L. Samuel ;
Estes, N. A. Mark, III ;
Ezekowitz, Michael D. ;
Jackman, Warren M. ;
January, Craig T. ;
Page, Richard L. ;
Slotwiner, David J. ;
Stevenson, William G. ;
Tracy, Cynthia M. ;
Jacobs, Alice K. ;
Anderson, Jeffrey L. ;
Albert, Nancy ;
Buller, Christopher E. ;
Creager, Mark A. ;
Ettinger, Steven M. ;
Guyton, Robert A. ;
Hochman, Judith S. ;
Kushner, Frederick G. ;
Ohman, Erik Magnus ;
Tarkington, Lynn G. ;
Yancy, Clyde W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (11) :E101-E198
[10]   Research electronic data capture (REDCap)-A metadata-driven methodology and workflow process for providing translational research informatics support [J].
Harris, Paul A. ;
Taylor, Robert ;
Thielke, Robert ;
Payne, Jonathon ;
Gonzalez, Nathaniel ;
Conde, Jose G. .
JOURNAL OF BIOMEDICAL INFORMATICS, 2009, 42 (02) :377-381