Diffusion MRI with pulsed and free gradient waveforms: Effects of restricted diffusion and exchange

被引:17
|
作者
Chakwizira, Arthur [1 ]
Westin, Carl-Fredrik [2 ]
Brabec, Jan [1 ]
Lasic, Samo [3 ,4 ]
Knutsson, Linda [1 ,5 ,6 ]
Szczepankiewicz, Filip [1 ]
Nilsson, Markus [7 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[2] Harvard Med Sch, Dept Radiol, Brigham & Womens Hosp, Boston, MA 02115 USA
[3] Copenhagen Univ Hosp Amager & Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Copenhagen, Denmark
[4] Random Walk Imaging AB, Lund, Sweden
[5] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[6] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD USA
[7] Lund Univ, Dept Clin Sci Lund, Radiol, Lund, Sweden
基金
瑞典研究理事会; 欧洲研究理事会; 美国国家卫生研究院;
关键词
cumulant expansion; diffusion MRI; exchange; gradient waveform; restricted diffusion; restriction-exchange space; restriction-exchange weighting; time dependence; OPTIMAL EXPERIMENTAL-DESIGN; TIME-DEPENDENT DIFFUSION; FIELD-GRADIENT; WATER DIFFUSION; MAGNETIC-RESONANCE; SELF-DIFFUSION; CELL-SIZE; IN-VIVO; ANALYTICAL-MODEL; NMR DIFFUSION;
D O I
10.1002/nbm.4827
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Monitoring time dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can lead to errors in parameter estimates. In this work, we propose a signal representation that incorporates the effects of both restricted diffusion and exchange up to second order in b-value and is compatible with gradient waveforms of arbitrary shape. The representation features mappings from a gradient waveform to two scalars that separately control the sensitivity to restriction and exchange. We demonstrate that these scalars span a two-dimensional space that can be used to choose waveforms that selectively probe restricted diffusion or exchange, eliminating the correlation between the two phenomena. We found that waveforms with specific but unconventional shapes provide an advantage over conventional pulsed and oscillating gradient acquisitions. We also show that parametrization of waveforms into a two-dimensional space can be used to understand protocols from other approaches that probe restricted diffusion and exchange. For example, we found that the variation of mixing time in filter-exchange imaging corresponds to variation of our exchange-weighting scalar at a fixed value of the restriction-weighting scalar. The proposed signal representation was evaluated using Monte Carlo simulations in identical parallel cylinders with hexagonal and random packing as well as parallel cylinders with gamma-distributed radii. Results showed that the approach is sensitive to sizes in the interval 4-12 mu m$$ \upmu \mathrm{m} $$ and exchange rates in the simulated range of 0 to 20 s-1$$ {\mathrm{s}}<^>{-1} $$, but also that there is a sensitivity to the extracellular geometry. The presented theory constitutes a simple and intuitive description of how restricted diffusion and exchange influence the signal as well as a guide to protocol design capable of separating the two effects.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] In vivo detection of microscopic anisotropy using quadruple pulsed-field gradient (qPFG) diffusion MRI on a clinical scanner
    Avram, Alexandru V.
    Oezarslan, Evren
    Sarlls, Joelle E.
    Basser, Peter J.
    NEUROIMAGE, 2013, 64 : 229 - 239
  • [32] Observation of restricted diffusion in the presence of a free diffusion compartment: Single- and double-PFG experiments
    Shemesh, Noam
    Oezarslan, Evren
    Bar-Shir, Amnon
    Basser, Peter J.
    Cohen, Yoram
    JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (02) : 214 - 225
  • [33] Restricted diffusion in the brain on MRI: do not stop at stroke
    Rathore, Deepander Singh
    Brar, Rahat
    Dwivedi, Ankur
    Prasad, Abhishek
    Rana, Shaleen
    ACTA NEUROLOGICA BELGICA, 2017, 117 (04) : 957 - 960
  • [34] Restricted diffusion in the brain on MRI: do not stop at stroke
    Deepander Singh Rathore
    Rahat Brar
    Ankur Dwivedi
    Abhishek Prasad
    Shaleen Rana
    Acta Neurologica Belgica, 2017, 117 : 957 - 960
  • [35] Automated correction of improperly rotated diffusion gradient orientations in diffusion weighted MRI
    Jeurissen, Ben
    Leemans, Alexander
    Sijbers, Jan
    MEDICAL IMAGE ANALYSIS, 2014, 18 (07) : 953 - 962
  • [36] Cumulant expansions for measuring water exchange using diffusion MRI
    Ning, Lipeng
    Nilsson, Markus
    Lasic, Samo
    Westin, Carl-Fredrik
    Rathi, Yogesh
    JOURNAL OF CHEMICAL PHYSICS, 2018, 148 (07)
  • [37] Self-diffusion of polymers in cartilage as studied by pulsed field gradient NMR
    Trampel, R
    Schiller, J
    Naji, L
    Stallmach, F
    Kärger, J
    Arnold, K
    BIOPHYSICAL CHEMISTRY, 2002, 97 (2-3) : 251 - 260
  • [38] Mapping Immune Cells Infiltration Using Restricted Diffusion MRI
    Yeh, Fang-Cheng
    Ho, Chien
    2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [39] Imaging Local Diffusive Dynamics Using Diffusion Exchange Spectroscopy MRI
    Benjamini, Dan
    Komlosh, Michal E.
    Basser, Peter J.
    PHYSICAL REVIEW LETTERS, 2017, 118 (15)
  • [40] Effects of restricted diffusion on MR signal formation
    Sukstanskii, AL
    Yablonskiy, DA
    JOURNAL OF MAGNETIC RESONANCE, 2002, 157 (01) : 92 - 105