Efficacy of poller screw in addition to lag screw in the treatment of intertrochanteric fractures with proximal femoral nail: a biomechanical evaluation

被引:2
|
作者
Horoz, Levent [1 ]
Cakmak, Mehmet Fevzi [1 ]
Cici, Hakan [2 ]
机构
[1] Kirsehir Ahi Evran Univ, Kirsehir, Turkiye
[2] Demokrasi Univ, Izmir, Turkiye
关键词
Intertrochanteric fracture; Poller screw; Biomechanical study; Proximal femoral nail; SLIDING HIP SCREW; PERTROCHANTERIC FRACTURES; CEMENT AUGMENTATION; NECK FRACTURES; RISK-FACTORS; FIXATION; ANTIROTATION; FAILURE; PLATE;
D O I
10.1007/s00068-024-02477-z
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose The most common type of failure in treating intertrochanteric fractures with proximal femoral nails is cut-out due to varus collapse. We aim to evaluate the effect of the poller screw applied to the proximal fragment and the lag screw on varus collapse and stability in intertrochanteric fractures. Methods An unstable intertrochanteric fracture model without medial support was simulated in 20 synthetic femur models. In the poller screw group, in addition to the lag screw, pole screws were applied to the proximal fragment superior and inferior to the lag screw. In the progressive cyclic loading test, starting from 100 N, the loading was increased by 50 N in each cycle, and the test was continued until the maximum load at which failure occurred as a result of conditioning cycles and progressive cyclic loading tests, stiffness, type of failure, force at failure, lag screw displacement, and varus collapse were recorded. Result The average stiffness was found to be 124.705 N/mm in the poller screw group and 102.77 N/mm in the control group (P < 0.001). The maximum load to failure was 1897.10 N in the poller screw group and 1475.20 N in the control group (P < 0.001). The average displacement of the lag screw within the femoral head was 0.85 mm in the poller screw group and 3.60 mm in the control group (P < 0.001). Conclusion As a result, it has been shown that poller screws applied around the lag screw increase fixation stiffness and reduce varus collapse.
引用
收藏
页码:1591 / 1598
页数:8
相关论文
共 50 条
  • [41] Radiological evaluation of intertrochanteric fracture fixation by the proximal femoral nail
    Herman, Amir
    Landau, Yair
    Gutman, Gabriel
    Ougortsin, Vladislav
    Chechick, Aharon
    Shazar, Nachshon
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 856 - 863
  • [42] Femoral Head Lag Screw Position for Cephalomedullary Nails: A Biomechanical Analysis
    Kuzyk, Paul R. T.
    Zdero, Rad
    Shah, Suraj
    Olsen, Michael
    Waddell, James P.
    Schemitsch, Emil H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (07) : 414 - 421
  • [43] Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures
    von der Linden, P.
    Gisep, A.
    Boner, V.
    Windolf, M.
    Appelt, A.
    Suhm, N.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (12) : 2230 - 2237
  • [44] TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURE OF FEMUR WITH DYNAMIC HIP SCREW VERSUS PROXIMAL FEMORAL NAIL: A COMPARATIVE STUDY
    Chander, S. G.
    Kanagasarathy, K.
    Chander, Vijaysharathy
    Reddy, Narayana M.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (59): : 10284 - 10293
  • [45] Surgical Treatment of Type 31-A1 Two-part Intertrochanteric Femur Fractures: Is Proximal Femoral Nail Superior to Dynamic Hip Screw Fixation?
    Mohan, Hariharan
    Kumar, Prakash
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (02)
  • [46] Comparison of clinical outcomes with proximal femoral nail anti-rotation versus dynamic hip screw for unstable intertrochanteric femoral fractures: A meta-analysis
    Zhang, Cong
    Chen, Zhangxin
    Wang, Mengyuan
    Chen, Wei
    Ding, Zhenqi
    MEDICINE, 2023, 102 (06) : E32920
  • [47] Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails
    Lee, Cheng-Hung
    Su, Kuo-Chih
    Chen, Kun-Hui
    Pan, Chien-Chou
    Wu, Yun-Che
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (06) : 2128 - 2140
  • [48] Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures
    Nherera, Leo
    Trueman, Paul
    Horner, Alan
    Watson, Tracy
    Johnstone, Alan J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [49] Comparison of Proximal Femoral Nail Antirotation and Dynamic Hip Screw Internal Fixation on Serum Markers in Elderly Patients with Intertrochanteric Fractures
    Wang, Bin
    Liu, Qingbai
    Liu, Yu
    Jiang, Rui
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (07): : 644 - 648
  • [50] Predictors of failure following fixation of intertrochanteric fractures with proximal femoral nail antirotation
    Raghuraman, Raghavan
    Kam, Jia Wen
    Chua, David Thai Chong
    SINGAPORE MEDICAL JOURNAL, 2019, 60 (09) : 463 - 467