Efficacy of poller screw in addition to lag screw in the treatment of intertrochanteric fractures with proximal femoral nail: a biomechanical evaluation

被引:2
|
作者
Horoz, Levent [1 ]
Cakmak, Mehmet Fevzi [1 ]
Cici, Hakan [2 ]
机构
[1] Kirsehir Ahi Evran Univ, Kirsehir, Turkiye
[2] Demokrasi Univ, Izmir, Turkiye
关键词
Intertrochanteric fracture; Poller screw; Biomechanical study; Proximal femoral nail; SLIDING HIP SCREW; PERTROCHANTERIC FRACTURES; CEMENT AUGMENTATION; NECK FRACTURES; RISK-FACTORS; FIXATION; ANTIROTATION; FAILURE; PLATE;
D O I
10.1007/s00068-024-02477-z
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose The most common type of failure in treating intertrochanteric fractures with proximal femoral nails is cut-out due to varus collapse. We aim to evaluate the effect of the poller screw applied to the proximal fragment and the lag screw on varus collapse and stability in intertrochanteric fractures. Methods An unstable intertrochanteric fracture model without medial support was simulated in 20 synthetic femur models. In the poller screw group, in addition to the lag screw, pole screws were applied to the proximal fragment superior and inferior to the lag screw. In the progressive cyclic loading test, starting from 100 N, the loading was increased by 50 N in each cycle, and the test was continued until the maximum load at which failure occurred as a result of conditioning cycles and progressive cyclic loading tests, stiffness, type of failure, force at failure, lag screw displacement, and varus collapse were recorded. Result The average stiffness was found to be 124.705 N/mm in the poller screw group and 102.77 N/mm in the control group (P < 0.001). The maximum load to failure was 1897.10 N in the poller screw group and 1475.20 N in the control group (P < 0.001). The average displacement of the lag screw within the femoral head was 0.85 mm in the poller screw group and 3.60 mm in the control group (P < 0.001). Conclusion As a result, it has been shown that poller screws applied around the lag screw increase fixation stiffness and reduce varus collapse.
引用
收藏
页码:1591 / 1598
页数:8
相关论文
共 50 条
  • [1] Comparative efficacy of proximal femoral nail vs dynamic condylar screw in treating unstable intertrochanteric fractures
    Mohamed, Ahmed Mohamed Yousif
    Salih, Monzir
    Abdulgadir, Mohanad
    Abbas, Ayman E.
    Turjuman, Duha Lutfi
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (08): : 796 - 806
  • [2] Computed Tomographic Image Analysis of Proximal Femoral Nail Antirotation and Dynamic Hip Screw in the Treatment of Intertrochanteric Fractures
    Teng, Yugang
    Zhang, Yuanzhen
    Wang, Zhenyu
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (08) : 1746 - 1752
  • [3] A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures
    Huang, Yanfeng
    Zhang, Chunlin
    Luo, Yi
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2465 - 2473
  • [4] Biomechanical evaluation of the modified proximal femoral nail for the treatment of reverse obliquity intertrochanteric fractures
    Wang, Qian
    Sun, Liang
    Liu, Lu
    Ma, Teng
    Li, Zhong
    Zhang, Kun
    Huang, Qiang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [5] Proximal Femoral Nail vs. Dynamic Hip Screw in Treatment of Intertrochanteric Fractures: A Meta-Analysis
    Zhang, Kairui
    Zhang, Sheng
    Yang, Jun
    Dong, Weiqiang
    Wang, Shengnan
    Cheng, Yirong
    Al-Qwbani, Mohammed
    Wang, Qiang
    Yu, Bin
    MEDICAL SCIENCE MONITOR, 2014, 20 : 1628 - 1633
  • [6] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [7] Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
    Wang, Chaofeng
    Duan, Ning
    Li, Zhong
    Ma, Teng
    Zhang, Kun
    Wang, Qian
    Huang, Qiang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [8] Limited Dynamic Hip Screw for Treatment of Intertrochanteric Fractures: A Biomechanical Study
    Zhang, Chunlei
    Zhang, Bin
    Dong, Qirong
    Ge, Dawei
    MEDICAL SCIENCE MONITOR, 2018, 24 : 1769 - 1775
  • [9] Comparison of helical blade versus lag screw in intertrochanteric fractures of the elderly treated with proximal femoral nail: A meta-analysis of randomized-controlled trials
    Huang, Jiazhi
    Wei, Qingjun
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (03) : 695 - 704
  • [10] Effect of hydroxyapatite tubes on the lag screw intraoperative insertion torque for the treatment of intertrochanteric femoral fractures
    Iwata, Hidetoshi
    Takada, Naoya
    Kuroyanagi, Gen
    Ikuta, Kenji
    Usami, Takuya
    Sekiya, Isato
    Murakami, Hideki
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (11): : 3377 - 3381