Femoral Neck Fractures Treated by Closed Reduction and Internal Fixation with the Double Fluoroscope Technique: A Preliminary Study

被引:0
作者
Lee, Hyun Hee [1 ,2 ]
Kang, Kyung-Yil [1 ,3 ]
Sung, Seung-Yong [1 ]
Lee, Soo-Bin [1 ]
Kim, Sang-Hee [1 ]
Jung, Su-Il [1 ,3 ]
Shin, Dong Hyuk [4 ]
Oh, Byung Hak [4 ]
Chae, Dong-Sik [1 ]
机构
[1] Catholic Kwandong Univ, Int St Marys Hosp, Coll Med, Dept Orthoped Surg, Incheon 22711, South Korea
[2] Yonsei Grad Sch, Coll Med, Seoul 03722, South Korea
[3] Catholic Kwandong Grad Sch, Coll Med, Gangneungsi 25601, South Korea
[4] Konyang Univ Hosp, Dept Orthoped Surg, Daejeon 35365, South Korea
基金
新加坡国家研究基金会;
关键词
femoral neck fractures; closed reduction; internal fixation; double C-arm; radiation exposure reduction; RADIATION-EXPOSURE; RISK;
D O I
10.3390/jcm13051418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fractures of the femur require significant radiation exposure during operations using fluoroscopy (C-arm), posing a high risk of radiation exposure to the medical staff and patients. To address this concern, in this study, we investigated the efficacy of using two fluoroscopy machines simultaneously. Methods: We categorized 30 patients with femoral neck fracture (FNF) into single and double C-arm groups. The operation and radiation exposure times during a closed reduction and internal fixation operation were investigated to evaluate whether the operation and radiation exposure times were effectively audited when the operation was performed using a double C-arm. Results: The total operation times were 93.21 +/- 20.70 min and 66.69 +/- 13.97 min for the single and double C-arm groups, respectively. Additionally, the total radiation times were 100.43 +/- 24.59 s and 83.06 +/- 19.53 s for the single and double C-arm groups, respectively. Operation and radiation exposure times in the two groups showed statistically significant differences (p < 0.05). Conclusion: The use of double C-arm in FNF can reduce operation and radiation exposure times. Hence, using the double C-arm in surgical treatment could reduce the risk of radiation exposure to medical staff and patients.
引用
收藏
页数:9
相关论文
共 26 条
[1]  
Bailey J., 2022, Orthop. Trauma, V36, P194, DOI [10.1016/j.mporth.2022.06.001, DOI 10.1016/J.MPORTH.2022.06.001]
[2]   Prospective Assessment of the Oncogenic Risk to Patients From Fluoroscopy During Trauma Surgery [J].
Beebe, Michael J. ;
Jenkins, Peter ;
Rothberg, David L. ;
Kubiak, Erik N. ;
Higgins, Thomas F. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (07) :E223-E229
[3]   Fluoroscopic radiation exposure of the kyphoplasty patient [J].
Boszczyk, BM ;
Bierschneider, M ;
Panzer, S ;
Panzer, W ;
Harstall, R ;
Schmid, K ;
Jaksche, H .
EUROPEAN SPINE JOURNAL, 2006, 15 (03) :347-355
[4]   Percutaneous cannulated screw fixation of femoral neck fractures: The three point principle [J].
Bout, CA ;
Cannegieter, DM ;
Juttmann, JW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (02) :135-139
[5]   Closed reduction and internal fixation for intertrochanteric femoral fractures is safer and more efficient using two fluoroscopes simultaneously [J].
Brin, Y. S. ;
Palmanovich, E. ;
Aliev, E. ;
Laver, L. ;
Yaacobi, E. ;
Nyska, M. ;
Kish, B. J. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (07) :1071-1075
[6]  
Cho Youngho, 2023, Hip Pelvis, V35, P47, DOI 10.5371/hp.2023.35.1.47
[7]   Radiation exposure in spine surgery using an image-guided system based on intraoperative cone-beam computed tomography: analysis of 107 consecutive cases [J].
Costa, Francesco ;
Tosi, Giovanni ;
Attuati, Luca ;
Cardia, Andrea ;
Ortolina, Alessandro ;
Grimaldi, Marco ;
Galbusera, Fabio ;
Fornari, Maurizio .
JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (05) :654-659
[8]   Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels [J].
Crawley, MT ;
Rogers, AT .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871) :740-744
[9]   Technologies for Young Femoral Neck Fracture Fixation [J].
Duffin, Matthew ;
Pilson, Holly T. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 :S20-S26
[10]   Ionising radiation during internal fixation of extracapsular neck of femur fractures [J].
Giannoudis, PV ;
McGuigan, J ;
Shaw, DL .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06) :469-472