Implementation of geant4 application for tomography emission Monte Carlo Code in the calculation of dose distribution in external radiation therapy

被引:0
作者
Dehghan, A. B. Yeke [1 ]
Mostaar, A. [1 ,2 ]
Azadeh, P. [3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Iran Univ Med Sci, Radiat Biol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Med, Dept Radiat Oncol, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2023年 / 21卷 / 04期
关键词
GATE; geant4; Monte Carlo Code; photon beam; COLLAPSED CONE CONVOLUTION; CALCULATION ALGORITHMS; SIMULATION PLATFORM; TISSUE PARAMETERS; CT NUMBERS; GATE; VERIFICATION; RADIOTHERAPY; MODEL; PET;
D O I
10.61186/ijrr.21.4.663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The "Geant4 Application for Tomography Emission" (GATE) toolkit comprises advanced open-source Monte Carlo (MC) code for use in medical imaging and radiotherapy simulations. This study aimed to verify the GATE toolkit results against a water phantom and then to show the dose calculation capabilities of the GATE for radiotherapy. The results were compared with three dose calculation algorithms using patients' Computerized Tomography (CT) data. Materials and Methods: A Linac with a 6 MV photon beam was simulated in the GATE code. The code was verified, head CT images of three patients were inserted into the GATE as realistic phantoms , and simulations were performed for different field sizes and angles. The Percent Depth Doses (PDDs) and transverse profiles were extracted from the GATE simulation and calculation algorithms. Their results were compared regarding the Dose Difference (DD) and gamma index for the PDDs and the Full Width at Half Maximum (FWHM) for the profiles. Results: Using the patient CT data for the PDDs, the gamma pass rate with 3%/3 mm criteria in the comparison between the GATE simulation and algorithms for all fields ranged from 89.4% to 98.8%, with an average of 92.8%. The extracted FWHMs from the GATE and algorithms were in good agreement, and their differences ranged from 0.1 to 1.2 mm. Conclusions: The GATE MC toolkit has good potential for implementation in radiotherapy Treatment Planning Systems (TPS) for dose calculations.
引用
收藏
页数:12
相关论文
共 47 条
[1]   Representation and illustration of the initial parameters in GATE 8.1 monte carlo simulation of an Elekta Versa-HD linear accelerator [J].
Abolaban, Fouad A. ;
Taha, Eslam M. .
JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2020, 13 (01) :642-647
[2]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[3]   A study to assess and improve dose computations in photon beam therapy [J].
Aspradakis, MM .
MEDICAL PHYSICS, 1997, 24 (08) :1334-1334
[4]   Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations [J].
Benhalouche, S. ;
Visvikis, D. ;
Le Maitre, A. ;
Pradier, O. ;
Boussion, N. .
MEDICAL PHYSICS, 2013, 40 (02)
[5]  
Brualla L, 2017, STRAHLENTHER ONKOL, V193, P243, DOI 10.1007/s00066-016-1075-8
[6]   Verification of the Elekta Monaco TPS Monte Carlo in modelling radiation transmission through metals in a water equivalent phantom [J].
Byrnes, Kurt ;
Ford, Andriana ;
Bennie, Nick .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) :639-645
[7]  
Chopra KL., 2018, Ther Radiol Oncol, V2, P28, DOI [DOI 10.21037/TRO.2018.07.01, 10.21037/tro.2018.07.01]
[8]   Variations of lung density and geometry on inhomogeneity correction algorithms: A Monte Carlo dosimetric evaluation [J].
Chow, James C. L. ;
Leung, Michael K. K. ;
Van Dyk, Jake .
MEDICAL PHYSICS, 2009, 36 (08) :3619-3630
[9]   Dosimetric and Monte Carlo verification of jaws-only IMRT plans calculated by the Collapsed Cone Convolution algorithm for head and neck cancers [J].
Duong Thanh Tai ;
Luong Thi Oanh ;
Nguyen Dong Son ;
Truong Thi Hong Loan ;
Chow, James C. L. .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (01) :105-114
[10]   Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy [J].
Elcim, Yelda ;
Dirican, Bahar ;
Yavas, Omer .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05) :616-624