A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

被引:4
作者
King-Doonan, Elizabeth K. [1 ,2 ]
Bilenker, Laura D. [1 ,3 ]
Weis, Dominque [1 ]
Gordon, Kathy [1 ]
Fourny, Anais [1 ,5 ]
Patton, Genna M. [1 ,6 ]
Zhao, Ye [4 ]
机构
[1] Univ British Columbia, Pacific Ctr Isotop & Geochem Res, Dept Earth Ocean & Atmospher Sci, Multidisciplinary Appl Geochem Network, Vancouver, BC V6T 1Z4, Canada
[2] DEVCOM ARL, Army Res Off, Durham, NC 27709 USA
[3] Auburn Univ, Dept Geosci, Coll Sci & Math, Auburn, AL 36849 USA
[4] Nu Instrument Ltd, 74 Clywedog Rd South, Wrexham LL13 9XS, Wales
[5] Canadian Nucl Labs, Chalk River, ON K0J 1J0, Canada
[6] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
基金
加拿大自然科学与工程研究理事会;
关键词
iron isotopes; non-traditional stable isotope; geochemistry; mass spectrometry; correction method; standard-sample bracketing; RATIO MEASUREMENTS; MASS-SPECTROMETRY; DOUBLE SPIKE; IRON; FRACTIONATION; PRECISE; CONSTRAINTS; COPPER; BIAS; INTERFERENCES;
D O I
10.1111/ggr.12541
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." This study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.
引用
收藏
页码:309 / 330
页数:22
相关论文
共 56 条
  • [1] Isotopic evidence of unaccounted for Fe and Cu erythropoietic pathways
    Albarede, Francis
    Telouk, Philippe
    Lamboux, Aline
    Jaouen, Klervia
    Balter, Vincent
    [J]. METALLOMICS, 2011, 3 (09) : 926 - 933
  • [2] Sources of mass bias and isotope ratio variation in multicollector ICP-MS:: optimization of instrumental parameters based on experimental observations
    Andrén, H
    Rodushkin, I
    Stenberg, A
    Malinovsky, D
    Baxter, DC
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) : 1217 - 1224
  • [3] An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry
    Barling, Jane
    Weis, Dominique
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) : 653 - 662
  • [4] Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry
    Baxter, DC
    Rodushkin, I
    Engström, E
    Malinovsky, D
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (04) : 427 - 430
  • [5] Beard BL, 2003, GEOLOGY, V31, P629, DOI 10.1130/0091-7613(2003)031<0629:IICOFC>2.0.CO
  • [6] 2
  • [7] High precision measurement of iron isotopes by plasma source mass spectrometry
    Belshaw, NS
    Zhu, XK
    Guo, Y
    O'Nions, RK
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 : 191 - 195
  • [8] THE APPLICATION OF STABLE Fe ISOTOPES TO MAGMATIC SULFIDE SYSTEMS: CONSTRAINTS ON THE Fe ISOTOPE COMPOSITION OF MAGMATIC PYRRHOTITE
    Bilenker, Laura D.
    Weis, Dominique
    Scoates, James S.
    Perry, Eden
    [J]. ECONOMIC GEOLOGY, 2018, 113 (05) : 1181 - 1192
  • [9] Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
    Brand, Willi A.
    Coplen, Tyler B.
    Vogl, Jochen
    Rosner, Martin
    Prohaska, Thomas
    [J]. PURE AND APPLIED CHEMISTRY, 2014, 86 (03) : 425 - 467
  • [10] Evaluation of the use of cold plasma conditions for Fe isotopic analysis via multi-collector ICP-mass spectrometry: effect on spectral interferences and instrumental mass discrimination
    Chernonozhkin, Stepan M.
    Costas-Rodriguez, Marta
    Claeys, Philippe
    Vanhaecke, Frank
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (03) : 538 - 547