Development and validation of a clinical tool to semi-automatic measure three-dimensional TAR alignment on two-dimensional radiographs

被引:1
作者
van Hoogstraten, Sanne W. G. [1 ,2 ]
Hermus, Joris [1 ]
Verbiest, Vera [2 ]
van Rietbergen, Bert [1 ,2 ]
Arts, Jacobus J. C. [1 ,2 ]
机构
[1] Maastricht Univ Med Ctr, Dept Orthoped Surg, Lab Expt Orthoped, Maastricht, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn Orthoped Biomech, Eindhoven, Netherlands
关键词
Total Ankle Replacement; Malalignment; Radiographic measurements; Subsidence; Migration; TOTAL ANKLE REPLACEMENT; RADIOSTEREOMETRIC ANALYSIS; FOLLOW-UP; DEFORMITY; ARTHROPLASTIES; PROSTHESIS; MIGRATION; REGISTER; TERM;
D O I
10.1186/s13047-023-00640-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Malalignment is often postulated as an important reason for the high failure rate of total ankle replacements (TARs). The correlation between TAR malalignment and clinical outcome, however, is not fully understood. Improving and expanding radiographic TAR alignment measurements in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurements on radiographs in the clinic. Methods A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed in MATLAB. Using the principle of edge contouring and the perpendicular relationship between the anteroposterior and lateral radiographs, the exact configuration of the TAR components can be found. Two observers validated the tool by measuring TAR alignment of ten patients using the tool. The Intraclass Coefficient (ICC) was calculated to assess the reliability of the developed method. The results obtained by the tool were compared to clinical results during radiographic follow-up in the past, and the accuracy of both methods was calculated using three-dimensional CT data. Results The tool showed an accuracy of 76% compared to 71% for the method used during follow-up. ICC values were 0.94 (p < 0.01) and higher for both inter-and intra-observer reliability. Conclusions The tool presents a reproducible method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to most TAR designs, it offers a valuable addition in the clinic and for research purposes.
引用
收藏
页数:9
相关论文
共 45 条
  • [31] Accuracy assessment of measuring component position after total ankle arthroplasty using a conventional method
    Lee, Kyoung-Jai
    Wang, Shao-Hua
    Lee, Gun-Woo
    Lee, Keun-Bae
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [32] Imaging of Ankle Replacements
    LiMarzi, Gary M.
    Fursevich, Dzmitry M.
    Cole, J. Dean
    Wasyliw, Christopher W.
    Bancroft, Laura W.
    [J]. SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (01) : 67 - 76
  • [33] Evaluation of hindfoot dimensions: A radiological study
    Magerkurth, Olaf
    Knupp, Markus
    Ledermann, Hanspeter
    Hintermann, Beat
    [J]. FOOT & ANKLE INTERNATIONAL, 2006, 27 (08) : 612 - 616
  • [34] Increased Radiographic Posterior Tibial Slope Is Associated With Subsequent Injury Following Revision Anterior Cruciate Ligament Reconstruction
    Napier, Richard J.
    Garcia, Enrique
    Devitt, Brian M.
    Feller, Julian A.
    Webster, Kate E.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (11)
  • [35] Early migration of the tibial component of the Buechel-Pappas total ankle prosthesis
    Nelissen, Rob G. H. H.
    Doets, H. Cornelis
    Valstar, Edward R.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) : 146 - 151
  • [36] The use of three-dimensional biometric Foot and Ankle Offset to predict additional realignment procedures in total ankle replacement
    Netto, Cesar de Cesar
    Day, Jonathan
    Godoy-Santos, Alexandre Leme
    Roney, Andrew
    Mansur, Nacime S. Barbachan
    Lintz, Francois
    Ellis, Scott J.
    Demetracopoulos, Constantine A.
    [J]. FOOT AND ANKLE SURGERY, 2022, 28 (07) : 1029 - 1034
  • [37] PALEY D, 1994, ORTHOP CLIN N AM, V25, P425
  • [38] Subsidence of SB Charit, total disc replacement and the role of undersizing
    Punt, Ilona
    van Rijsbergen, Marc
    van Rietbergen, Bert
    Ito, Keita
    van Rhijn, Lodewijk
    van Ooij, Andre
    Willems, Paul
    [J]. EUROPEAN SPINE JOURNAL, 2013, 22 (10) : 2264 - 2270
  • [39] Results of more than 11,000 scans with weightbearing CT-Impact on costs, radiation exposure, and procedure time
    Richter, Martinus
    Lintz, Francois
    Netto, Cesar de Cesar
    Barg, Alexej
    Burssens, Arne
    [J]. FOOT AND ANKLE SURGERY, 2020, 26 (05) : 518 - 522
  • [40] Fast algorithm for Probabilistic bone edge detection (FAPBED)
    Scepanovic, D
    Kirshtein, J
    Jain, AK
    Taylor, RH
    [J]. MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 1753 - 1765