The Left Outflow Tract in Fetal Cardiac Screening Examination: Introduction of Quality Criteria Is Not Always Associated With an Improvement of Practice When Supervised by Humans

被引:0
|
作者
Regouin, Maud [1 ]
Mancini, Julien [2 ]
Lafouge, Antoine [3 ]
Mace, Pierre [4 ,5 ]
Fontaine, Nathalie [1 ]
Roussin, Stephanie [6 ]
Guichard, Jimmy [7 ]
Dumont, Coralie [1 ]
Quarello, Edwin [4 ,8 ,9 ]
机构
[1] Hop Sud Reunion, Dept Gynecol Obstet, Le Tampon, Reunion, France
[2] Aix Marseille Univ, Hop Timone, AP HM, Publ Hlth Dept BIOSTIC,INSERM,IRD,SESSTIM, Marseille, France
[3] Cabinet Gynecol & Obstet, Hyeres, France
[4] Inst Mediterraneen Imagerie Med Appl Gynecol Gross, Marseille, France
[5] Hop Beauregard, Marseille, France
[6] Clin Anjou, Pole Mere Enfant, Angers, France
[7] Cabinet Echog Gynecol & Obstet Espace 9Mois, Montreuil, France
[8] Hop St Joseph, Unite Depistage & Diagnost Prenatal, Marseille, France
[9] Image 2 Ctr, 6 Rue Rocca, Marseille, France
关键词
fetal cardiac examination; left ventricular outflow tract; prenatal; quality criteria; ultrasound; PRACTICE GUIDELINES; PRENATAL DETECTION; HEART; IMPACT; TRANSPOSITION; OUTCOMES; IMAGES;
D O I
10.1002/jum.16231
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Since 2016, the French CNEOF included the left ventricular outflow tract (LVOT) in the second and third trimester of pregnancy in addition to the four-chamber view and the parasagittal view of the right outflow tract. The objective of this study was to define quality criteria for fetal LVOT assessment and to perform a human audit of past and current practices, before and after the implementation of those quality criteria at a large scale.Methods-Seven quality criteria were investigated and rated from 0 to 1 during three periods of interest. Files were randomly selected from three centers, and average total and specific scores were calculated.Results-LVOT pictures were present in more than 94.3% of reports. The average quality score was 5.49/7 (95% confidence interval [CI]: 5.36-5.62), 5.91/7 (95% CI: 5.80-6.03), and 5.70/7 (95% CI: 5.58-5.82) for the three centers in the three periods of interest. There was no significant difference following the introduction of the quality criteria, 2017 versus 2020, P = .054.Conclusion-Fetal LVOT images were present in most of ultrasound reports but the introduction of the proposed quality criteria under human supervision seems not associated with a significant change in practice.
引用
收藏
页码:2095 / 2105
页数:11
相关论文
empty
未找到相关数据