Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes: a dynamic phantom study

被引:14
作者
Dobrolinska, Magdalena M. M. [1 ,2 ,3 ]
van der Werf, Niels R. R. [3 ]
van der Bie, Judith [3 ]
de Groen, Joel [3 ]
Dijkshoorn, Marcel [3 ]
Booij, Ronald [3 ]
Budde, Ricardo P. J. [3 ]
Greuter, Marcel J. W. [1 ,4 ]
van Straten, Marcel [3 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Groningen, Netherlands
[2] Med Univ Silesiain, Div Cardiol & Struct Heart Dis, Katowice, Poland
[3] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[4] Univ Twente, Dept Robot & Mechatron, Enschede, Netherlands
关键词
X-ray computed tomography; Calcium; Coronary vessels; Imaging phantoms; HEART-RATE; QUANTIFICATION; MOTION;
D O I
10.1007/s00330-023-09434-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom.MethodsA hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, < 60, 60-75, and > 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p < 0.05 indicating significant differences.ResultsA decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes.ConclusionPCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a >= 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate.
引用
收藏
页码:4668 / 4675
页数:8
相关论文
共 32 条
[1]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]  
[Anonymous], 2020, EUR HEART J, DOI [DOI 10.1093/eurheartj/ehz455, DOI 10.1093/EURHEARTJ/EHZ455]
[4]   Dose reduction for CT coronary calcium scoring with a calcium-aware image reconstruction technique: a phantom study [J].
Booij, Ronald ;
van der Werf, Niels R. ;
Budde, Ricardo P. J. ;
Bos, Daniel ;
van Straten, Marcel .
EUROPEAN RADIOLOGY, 2020, 30 (06) :3346-3355
[5]   Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT-First Evidence from Phantom and In-Vivo Scans [J].
Eberhard, Matthias ;
Mergen, Victor ;
Higashigaito, Kai ;
Allmendinger, Thomas ;
Manka, Robert ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Euler, Andre ;
Alkadhi, Hatem .
DIAGNOSTICS, 2021, 11 (09)
[6]   Basic principles and clinical potential of photon-counting detector CT [J].
Flohr, Thomas ;
Ulzheimer, Stefan ;
Petersilka, Martin ;
Schmidt, Bernhard .
CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2020, 3 (01) :19-34
[7]  
Grundy SM, 2019, J AM COLL CARDIOL, V73, P3168, DOI [10.1016/j.jacc.2018.11.003, 10.1016/j.jacc.2018.11.002, 10.1161/CIR.0000000000000625]
[8]   Coronary artery motion and cardiac phases: Dependency on heart rate - Implications for CT image reconstruction [J].
Husmann, Lars ;
Leschka, Sebastian ;
Desbiolles, Lotus ;
Schepis, Tiziano ;
Gaemperli, Oliver ;
Seifert, Burkhardt ;
Cattin, Philippe ;
Frauenfelder, Thomas ;
Flohr, Thomas G. ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
RADIOLOGY, 2007, 245 (02) :567-576
[9]   Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology [J].
Leng, Shuai ;
Bruesewitz, Michael ;
Tao, Shengzhen ;
Rajendran, Kishore ;
Halaweish, Ahmed F. ;
Campeau, Norbert G. ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2019, 39 (03) :729-743
[10]   CAC Score Improves Coronary and CV Risk Assessment Above Statin Indication by ESC and AHA/ACC Primary Prevention Guidelines [J].
Mahabadi, Amir A. ;
Moehlenkamp, Stefan ;
Lehmann, Nils ;
Kaelsch, Hagen ;
Dykun, Iryna ;
Pundt, Noreen ;
Moebus, Susanne ;
Joeckel, Karl-Heinz ;
Erbel, Raimund .
JACC-CARDIOVASCULAR IMAGING, 2017, 10 (02) :143-153