Patient and physician radiation exposure during minimally invasive lumbar decompression: A prospective assessment of X-ray exposure risks

被引:0
|
作者
Mekhail, Nagy [1 ]
Topalsky, Krista [2 ]
Templeton, Erin [1 ]
Armanyous, Sherif [1 ]
Prayson, Nicholas [1 ]
Olde, Carl [1 ]
Costandi, Shrif [1 ]
机构
[1] Cleveland Clin, Pathol Dept, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Univ Hosp, Internal Med Dept, Cleveland, OH USA
关键词
fluoroscopy; lumbar decompression; lumbar spinal stenosis; minimally invasive; patients safety; physician's X-ray exposure; radiation exposure; spine surgery; SPINAL STENOSIS; MILD(R); OUTCOMES;
D O I
10.1111/papr.13329
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Introduction: Minimally invasive lumbar decompression (mild (R)) is becoming a popular procedure for treating lumbar spinal stenosis (LSS) secondary to hypertrophic ligamentum flavum (LF). The mild (R) procedure is commonly performed under live fluoroscopic guidance and carries a risk of radiation exposure to the patient and healthcare.Methods: One physician performed mild (R) on 41 patients at the Cleveland Clinic Department of Pain Management from October 2019 to December 2021, while wearing a radiation exposure monitor (Mirion Technologies). Mean fluoroscopy time, mean exposure per case, and mean exposure per unilateral level decompressed were the primary outcomes measured. The secondary outcome was to provide a comparison of radiation exposure during similar fluoroscopically guided procedures.Results: Mean patient fluoroscopy exposure time was 2.1 min +/- 0.9 (range: 1.1-5.6) fluoroscopy time per unilateral level decompressed. The mean patient radiation skin exposure from mild (R) was 1.1 +/- 0.9 mGym(2), and the mean total dose was 142.3 +/- 108.6 mGy per procedure. On average, the physician was exposed to an average deep tissue exposure of 4.1 +/- 3.2 mRem, 2.9 +/- 2.2 mRem estimated eye exposure, and 14.7 +/- 11.0 mRem shallow tissue exposure per unilateral level decompressed. An individual physician would exceed the annual exposure limit of 5 Rem after approximately 610 mild (R) procedures per year.Conclusions: This study is an attempt to quantify the radiation exposure to the physician and patient during the mild (R) procedure. Compared with other fluoroscopically guided pain management procedures, patient and physician radiation exposure during mild (R) was low.
引用
收藏
页码:600 / 608
页数:9
相关论文
共 50 条
  • [41] The Impact of Novel X-Ray Systems and X-Ray System Optimization on Patient Radiation Dose Administered During Cardiac Catheterization
    Vemmou, Evangelia
    Nikolakopoulos, Ilias
    Xenogiannis, Iosif
    Megaly, Michael
    Omer, Mohamed A.
    Stanberry, Larissa
    Garberich, Ross
    Rangan, Bavana, V
    Baran, Kenneth W.
    Gossl, Mario
    Sorajja, Paul
    Chavez, Ivan
    Mooney, Michael
    Traverse, Jay
    Wang, Yale
    Garcia, Santiago
    Poulose, Anil
    Burke, M. Nicholas
    Brilakis, Emmanouil S.
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (06) : 218 - 221
  • [42] Direction-changeable cage reduces X-ray exposure in treating isthmic lumbar spondylolisthesis: a retrospective study
    Zhang, Heiping
    Miao, Qiang
    Hao, Dingjun
    Zhao, Qinpeng
    He, Simin
    Wang, Biao
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (02): : 1066 - 1072
  • [43] Bodily structure and radiation exposure in dynamic X-ray procedures: A contribution to determine national reference data
    Golder, W
    Weiner, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (08): : 756 - 762
  • [44] Radiation Exposure During Lumbar Interbody Fusion Surgery Can Be Reduced by Using a Three-Dimensional Patient-Specific Template Guide
    Nagashima, Yuki
    Ishikawa, Tetsuhiro
    Katsuragi, Joe
    Sasaki, Yasuhito
    Suzuki, Masahiro
    Umimura, Tomotaka
    Sawada, Ryohei
    Hashiba, Daisuke
    Yamamoto, Makoto
    Ohtori, Seiji
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [45] Bodily structures and radiation exposure in static x-ray procedures: A contribution to determine national reference data.
    Golder, W
    Weiner, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (06): : 563 - 568
  • [46] Visualization of multiple catheters with electroanatomical mapping reduces X-ray exposure during atrial fibrillation ablation
    Scaglione, Marco
    Biasco, Luigi
    Caponi, Domenico
    Anselmino, Matteo
    Negro, Andrea
    Di Donna, Paolo
    Corleto, Antonella
    Montefusco, Antonio
    Gaita, Fiorenzo
    EUROPACE, 2011, 13 (07): : 955 - 962
  • [47] The Dose and Risk Factors for Radiation Exposure to Medical Staff during Endobronchial Ultrasonography with a Guide Sheath for Peripheral Pulmonary Lesions under X-ray Fluoroscopy
    Katsurada, Masahiro
    Izumo, Takehiro
    Nagai, Yuichi
    Chavez, Christine
    Kitagawa, Mayumi
    Torii, Jun
    Iwase, Takumi
    Aso, Tomohiko
    Tsuchida, Takaaki
    Sasada, Shinji
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2014, 44 (03) : 257 - 262
  • [48] Circulating tRNA-Derived Small RNAs as Novel Radiation Biomarkers of Heavy Ion, Proton and X-ray Exposure
    Wei, Wenjun
    Bai, Hao
    Chen, Yaxiong
    Zhang, Tongshan
    Zhang, Yanan
    Hua, Junrui
    He, Jinpeng
    Ding, Nan
    Zhou, Heng
    Wang, Jufang
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (24)
  • [49] Patient Radiation Dose Reduction during Transarterial Chemoembolization Using a Novel X-Ray Imaging Platform
    Kohlbrenner, Ryan
    Kolli, Pallav
    Taylor, Andrew G.
    Kohi, Maureen P.
    Fidelman, Nicholas
    LaBerge, Jeanne M.
    Kerlan, Robert K.
    Agarwal, Vishal K.
    Lehrman, Evan D.
    Nanavati, Sujal
    Avrin, David E.
    Gould, Robert
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (09) : 1331 - 1338
  • [50] Comparative study of open Transforaminal Lumbar Interbody Fusion (TLIF) and Minimally Invasive Transforaminal Lumbar Interbody Fusion (MISTLIF) based on clinical outcome, radiological outcome, tissue injury markers and radiation exposure
    Srikanth, T.
    Thota, Silpa
    Venkat, K.
    Chandra, V. VRamesh
    Prasad, B. C. M.
    JOURNAL OF KRISHNA INSTITUTE OF MEDICAL SCIENCES UNIVERSITY, 2023, 12 (01) : 107 - 114