Assessment of factors associated with improved glycemic control after switching from intermittently scanned to real-time continuous glucose monitoring in Japanese patients with type 1 diabetes

被引:0
|
作者
Yamada, Eijiro [1 ]
Nakajima, Yasuyo [1 ]
Horiguchi, Kazuhiko [1 ]
Okada, Shuichi [1 ]
Yamada, Masanobu [1 ]
机构
[1] Gunma Univ, Grad Sch Med, Dept Internal Med, Div Endocrinol & Metab, 3-39-15 Showa, Maebashi 3718511, Japan
关键词
Type; 1; diabetes; Real-time continuous glucose monitoring; Intermittently scanned continuous glucose monitoring; Glycated hemoglobin (HbA1c); Time below range; MULTICENTER; MANAGEMENT; ADULTS;
D O I
10.1507/endocrj.EJ23-0125
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The advantages of real-time continuous glucose monitoring (rtCGM) over intermittently scanned CGM (isCGM) reportedly include lower glycated hemoglobin (HbA1c) levels as well as reduced glycemic variability. However, there have been few studies of the effect of switching from isCGM to rtCGM on glycemic control, as well as the specific factors underlying any observed improvements. To that end, all patients with type 1 diabetes mellitus who used the DEXCOM rtCGM device (Terumo Corporation, Tokyo, Japan) at our institution were reviewed, and 16 individuals with type 1 diabetes who switched from isCGM to rtCGM were investigated. The patients' HbA1c decreased in 75% of the cases (p = 0.02). On the other hand, GMI increased in 75% of the cases (p = 0.01). Intriguingly, the percentage of time below range and coefficient of variation were significantly improved with rtCGM compared to isCGM (2.9% vs. 7.6%, p = 0.016 and 35% vs. 40%, p = 0.0019, respectively). We also found that the discrepancy between HbA1c and GMI among users of isCGM was a key indicator that improved when switching to rtCGM. If discrepancies are observed between HbA1c and GMI when using isCGM, switching to rtCGM should be considered for improving glycemic control.
引用
收藏
页码:1187 / 1193
页数:7
相关论文
共 50 条
  • [1] In type 1 diabetes, real-time vs. intermittently scanned continuous glucose monitoring improved glycemic control
    Olson, Darin E.
    ANNALS OF INTERNAL MEDICINE, 2021, 174 (10) : JC119 - JC119
  • [2] Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes
    Norgaard, Sidse Kjaerhus
    Mathiesen, Elisabeth Reinhardt
    Norgaard, Kirsten
    Ringholm, Lene
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 665 - 672
  • [3] Improved glycemic control with real-time continuous glucose sensors in patients with type 1 diabetes
    Ellis, Samuel L.
    Voelmle, Mary
    Gottlieb, Peter A.
    Gutin, Raymond
    Garg, Satish K.
    DIABETES, 2007, 56 : A119 - A120
  • [4] Comparison of glycaemic metrics from simultaneous use of intermittently scanned and real-time continuous glucose monitoring in patients with type 1 diabetes
    Siolos, A.
    Christou, M.
    Katsarou, D.
    Christou, P.
    Zessides, C.
    Georga, E.
    Fotiadis, D.
    Tigas, S.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S411 - S411
  • [5] Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    Deis, Dorothee
    Bolinder, Jan
    Riveline, Jean-Pierre
    Battelino, Tadej
    Bosi, Emanuele
    Tubiana-Rufi, Nadia
    Kerr, David
    Phillip, Moshe
    DIABETES CARE, 2006, 29 (12) : 2730 - 2732
  • [6] Intermittently Scanned Continuous Glucose Monitoring for Type 1 Diabetes
    Leelarathna, Lalantha
    Evans, Mark L. L.
    Neupane, Sankalpa
    Rayman, Gerry
    Lumley, Sarah
    Cranston, Iain
    Narendran, Parth
    Barnard-Kelly, Katharine
    Sutton, Christopher J. J.
    Elliott, Rachel A. A.
    Taxiarchi, Vicky P. P.
    Gkountouras, Georgios
    Burns, Matthew
    Mubita, Womba
    Kanumilli, Naresh
    Camm, Maisie
    Thabit, Hood
    Wilmot, Emma G. G.
    NEW ENGLAND JOURNAL OF MEDICINE, 2022, 387 (16): : 1477 - 1487
  • [7] Adherence to glucose monitoring with intermittently scanned continuous glucose monitoring in patients with type 1 diabetes
    Carolina Sousa
    João Sérgio Neves
    Cláudia Camila Dias
    Rute Sampaio
    Endocrine, 2023, 79 : 477 - 483
  • [8] Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes
    Guo, Lixin
    Li, Yuxiu
    Zhang, Mei
    Xiao, Xinhua
    Kuang, Hongyu
    Yang, Tao
    Jia, Xiaofan
    Zhang, Xianbo
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [9] Adherence to glucose monitoring with intermittently scanned continuous glucose monitoring in patients with type 1 diabetes
    Sousa, Carolina
    Neves, Joao Sergio
    Dias, Claudia Camila
    Sampaio, Rute
    ENDOCRINE, 2023, 79 (03) : 477 - 483
  • [10] Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
    Edelman, Steven V.
    Argento, Nicholas B.
    Pettus, Jeremy
    Hirsch, Irl B.
    DIABETES CARE, 2018, 41 (11) : 2265 - 2274