Dual-Conductive and Stiffness-Morphing Microneedle Patch Enables Continuous In Planta Monitoring of Electrophysiological Signal and Ion Fluctuation

被引:7
作者
Kong, Lingxuan [1 ]
Wen, Hanqi [1 ,2 ]
Luo, Yifei [3 ]
Chen, Xiaodong [4 ,5 ]
Sheng, Xing [6 ]
Liu, Yuxin [3 ,7 ,8 ,9 ]
Chen, Peng [1 ,5 ]
机构
[1] Nanyang Technol Univ, Sch Chem Chem Engn & Biotechnol, Singapore 637457, Singapore
[2] Inst Flexible Elect Technol THU, Jiaxing 314000, Zhejiang, Peoples R China
[3] Inst Mat Res & Engn, Agcy Sci Technol & Res ASTAR, 2 Fusionopolis Way, Singapore 138634, Singapore
[4] Nanyang Technol Univ, Innovat Ctr Flexible Devices IFLEX, Sch Mat Sci & Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[5] Nanyang Technol Univ, Inst Digital Mol Analyt & Sci IDMxS, Singapore 636921, Singapore
[6] Tsinghua Univ, Beijing Natl Res Ctr Informat Sci & Technol, Ctr Flexible Elect Technol, Dept Elect Engn, Beijing 100084, Peoples R China
[7] Natl Univ Singapore, Coll Design & Engn, Dept Biomed Engn, 4 Engn Dr 3, Singapore 117583, Singapore
[8] Natl Univ Singapore, Inst Hlth Innovat & Technol, Singapore 117599, Singapore
[9] Natl Univ Singapore, Inst Hlth N1, Singapore 117456, Singapore
关键词
conducting polymers; microneedle; plant physiology; smart agriculture; in situ biosensors; ELECTRODE ARRAY; CALCIUM; SOFT;
D O I
10.1021/acsami.3c08783
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The use of conductive microneedles presents a promising solution for achieving high-fidelity electrophysiological recordings with minimal impact on the interfaced tissue. However, a conventional metal-based microneedle suffers from high electrochemical impedance and mechanical mismatch. In this paper, we report a dual-conductive (i.e., both ionic and electronic conductive) and stiffness-morphing microneedle patch (DSMNP) for high-fidelity electrophysiological recordings with reduced tissue damage. The polymeric network of the DSMNP facilitates electrolyte absorption and therefore allows the transition of stiffness from 6.82 to 0.5139 N m(-1). Furthermore, the nanoporous conductive polymer increases the specific electrochemical surface area after tissue penetration, resulting in an ultralow specific impedance of 893.13 ? mm(2) at 100 Hz. DSMNPs detect variation potential and action potential in real time and cation fluctuations in plants in response to environmental stimuli. After swelling, DSMNPs mechanically "lock" into biological tissues and prevent motion artifact by providing a stable interface. These results demonstrate the potential of DSMNPs for various applications in the field of plant physiology research and smart agriculture.
引用
收藏
页码:43515 / 43523
页数:9
相关论文
共 40 条
  • [11] The hierarchical structure and mechanics of plant materials
    Gibson, Lorna J.
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2012, 9 (76) : 2749 - 2766
  • [12] Sodium Intake and Hypertension
    Grillo, Andrea
    Salvi, Lucia
    Coruzzi, Paolo
    Salvi, Paolo
    Parati, Gianfranco
    [J]. NUTRIENTS, 2019, 11 (09)
  • [13] Quantification of Plant Cell Death by Electrolyte Leakage Assay
    Hatsugai, Noriyuki
    Katagiri, Fumiaki
    [J]. BIO-PROTOCOL, 2018, 8 (05):
  • [14] The key mechanism of conductivity in PEDOT:PSS thin films exposed by anomalous conduction behaviour upon solvent-doping and sulfuric acid post-treatment
    Hosseini, Ehsan
    Kollath, Vinayaraj Ozhukil
    Karan, Kunal
    [J]. JOURNAL OF MATERIALS CHEMISTRY C, 2020, 8 (12) : 3982 - 3990
  • [15] A CALCIUM INFLUX PRECEDES ORGANOGENESIS IN GRAPTOPETALUM
    HUSH, JM
    OVERALL, RL
    NEWMAN, IA
    [J]. PLANT CELL AND ENVIRONMENT, 1991, 14 (07) : 657 - 665
  • [16] Cytosolic calcium and pH signaling in plants under salinity stress
    Kader, Md Abdul
    Lindberg, Sylvia
    [J]. PLANT SIGNALING & BEHAVIOR, 2010, 5 (03) : 233 - 238
  • [17] Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
    Kayser, Laure, V
    Lipomi, Darren J.
    [J]. ADVANCED MATERIALS, 2019, 31 (10)
  • [18] Arabidopsis H+-ATPase AHA1 controls slow wave potential duration and wound-response jasmonate pathway activation
    Kumari, Archana
    Chetelat, Aurore
    Nguyen, Chi Tam
    Farmer, Edward E.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (40) : 20226 - 20231
  • [19] A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring
    Lee, Su Jin
    Yoon, Hyo Sang
    Xuan, Xing
    Park, Jae Y.
    Paik, Seung-Joon
    Allen, Mark G.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 1144 - 1151
  • [20] The optimization of thermoelectric properties in a PEDOT:PSS thin film through post-treatment
    Liu, Siyao
    Deng, Hua
    Zhao, Yun
    Ren, Shijie
    Fu, Qiang
    [J]. RSC ADVANCES, 2015, 5 (03): : 1910 - 1917