Quantitative bioanalysis of proteins by digestion and LC-MS/MS: the use of multiple signature peptides

被引:5
作者
Sleumer, Bas [1 ,2 ,3 ]
Kema, Ido P. [3 ]
van de Merbel, Nico C. [1 ,2 ]
机构
[1] ICON Bioanalyt Labs, Amerikaweg 18, NL-9407 TK Assen, Netherlands
[2] Univ Groningen, Dept Analyt Biochem, A Deusinglaan 1, NL-9700 AV Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Lab Med, EA61,POB 30-001, NL-9700 RB Groningen, Netherlands
关键词
bioanalysis; confirmation; digestion; LC-MS/MS; protein biotransformation; protein isoforms; protein quantification; signature peptides; INTERNAL STANDARD; THERAPEUTIC PROTEINS; MONOCLONAL-ANTIBODY; QUANTIFICATION; SERUM; ASSAY; MS; ABSOLUTE; PRODUCTS; PLASMA;
D O I
10.4155/bio-2023-0129
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of multiple signature peptides for the quantification of proteins by digestion and LC-MS/MS is reviewed and evaluated here. A distinction is made based on the purpose of the use of multiple peptides: confirmation of the protein concentration, discrimination between different protein forms or species and in vivo biotransformation. Most reports that describe methods with at least two peptides use these for confirmation, but it is not always mentioned how the peptides are used and how possible differences in concentration between the peptides are handled. Differences in concentration are often reported in the case of monitoring different protein forms or in vivo biotransformation, and this offers insight into the biological fate of the protein.
引用
收藏
页码:1203 / 1216
页数:14
相关论文
共 56 条
[41]   Quantitative protein mass-spectrometry requires a standardized pre-analytical phase [J].
Smit, Nico P. M. ;
Romijn, Fred P. H. T. M. ;
van Ham, Vanessa J. J. ;
Reijnders, Esther ;
Cobbaert, Christa M. ;
Ruhaak, L. Renee .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (01) :55-66
[42]  
Strohalm M., 2023, mMass - Open Source Mass Spectrometry Tool
[43]   Multiplexing Determination of Small Cell Lung Cancer Biomarkers and Their Isovariants in Serum by Immunocapture LC-MS/MS [J].
Torsetnes, Silje B. ;
Levernaes, Maren S. ;
Broughton, Marianne N. ;
Paus, Elisabeth ;
Halvorsen, Trine G. ;
Reubsaet, Leon .
ANALYTICAL CHEMISTRY, 2014, 86 (14) :6983-6992
[44]  
van de Merbel N, 2019, WIL SER PHARM SCI BI, P304
[45]   LC-MS-based quantification of intact proteins: perspective for clinical and bioanalytical applications [J].
van den Broek, Irene ;
van Dongen, William D. .
BIOANALYSIS, 2015, 7 (15) :1943-1958
[46]   Evaluation of Interspecimen Trypsin Digestion Efficiency Prior to Multiple Reaction Monitoring-Based Absolute Protein Quantification with Native Protein Calibrators [J].
van den Broek, Irene ;
Smit, Nico P. M. ;
Romijn, Fred P. H. T. M. ;
van der Laarse, Arnoud ;
Deelder, Andre M. ;
van der Burgt, Yuri E. M. ;
Cobbaert, Christa M. .
JOURNAL OF PROTEOME RESEARCH, 2013, 12 (12) :5760-5774
[47]   Bioanalytical LC-MS/MS of protein-based biopharmaceuticals [J].
van den Broek, Irene ;
Niessen, Wilfried M. A. ;
van Dongen, William D. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 929 :161-179
[48]   15N-Labeled Full-Length Apolipoprotein E4 as an Internal Standard for Mass Spectrometry Quantification of Apolipoprotein E Isoforms [J].
Wang, Meiyao ;
Chen, Junjun ;
Turko, Illarion V. .
ANALYTICAL CHEMISTRY, 2012, 84 (19) :8340-8344
[49]   Serum apolipoprotein A-1 quantification by LC-MS with a SILAC internal standard reveals reduced levels in smokers [J].
Wang, Qingqing ;
Zhang, Suhong ;
Guo, Lili ;
Busch, Christine M. ;
Jian, Wenying ;
Weng, Naidong ;
Snyder, Nathaniel W. ;
Rangiah, Kannan ;
Mesaros, Clementina ;
Blair, Ian A. .
BIOANALYSIS, 2015, 7 (22) :2895-2911
[50]   A new methodology for simultaneous quantification of total-Aβ, Aβx-38, Aβx-40, and Aβx-42 by column-switching LC/MS/MS [J].
Watanabe, Ken-ichi ;
Ishikawa, Chihiro ;
Kuwahara, Hiroshi ;
Sato, Kimihiko ;
Komuro, Setsuko ;
Nakagawa, Tetsuya ;
Nomura, Naruaki ;
Watanabe, Shiro ;
Yabuki, Masashi .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) :2033-2042