Novel technique to reduce prolapsed device in atrial septal defect closure

被引:0
作者
Liao, Li-Chin [1 ,2 ]
Jan, Sheng-Ling [2 ]
Lin, Ming-Chih [2 ]
Lee, Ho-Hsun [3 ]
Fu, Yun-Ching [2 ,4 ,5 ]
机构
[1] Wuri Lin Shin Hosp, Dept Pediat, Taichung, Taiwan
[2] Taichung Vet Gen Hosp, Childrens Med Ctr, Dept Pediat, Taichung, Taiwan
[3] Good Day Psychiat Clin, Taichung, Taiwan
[4] Natl Chung Hsing Univ, Sch Med, Dept Pediat, Taichung, Taiwan
[5] Natl Yang Ming Chiao Tung Univ, Inst Clin Med, Dept Pediat, Taipei, Taiwan
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
atrial septal defect; push back technique; left atrial disc prolapse; transcatheter closure; transcatheter atrial septal defects closure; TRANSCATHETER CLOSURE; PREVENT PROLAPSE; OCCLUDER DEVICE;
D O I
10.3389/fcvm.2023.1164061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveTranscatheter closure of atrial septal defect (ASD) has become an alternative treatment to surgical repair. One of the challenges is the prolapse of the left atrial disc during the procedure. Many techniques have been developed to prevent the prolapse but not reduce it. In this study, we present a novel technique, termed push back technique, that help reduce the prolapsed device. MethodsWe enrolled 24 patients (8 males, 16 females) between May 2008 and January 2023 who underwent the push back technique during transcatheter closure of ASD in Taichung Veterans General Hospital. We recorded the hemodynamic data, success rate and complications including device embolization/migration, valvular regurgitation, pericardial effusion, and residual shunt. ResultsThe median age was 6.3 years (1.2-70.5 years) and the median weight was 19.1 kg (7.8-90 kg). Fifteen (62.5%) patients had mild pulmonary hypertension. The median Qp/Qs was 2.54 (1.5-8.8). The median ASD stretched size was 21.2 mm (7.7-35.3 mm). The median device size was 22 mm (8-40 mm). The median fluoroscopy time was 14 min (5-23 min) and median procedure time was 47 min (25-78 min). The push back technique successfully reduced the prolapsed device in 21 (87.5%) patients. There was no complication in all patients. ConclusionWe present a novel push back technique that can successfully reduce the prolapsed device in 87.5% (21/24) patients without complications. It is feasible, safe and effective.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Comparison of the OcclutechA® FigullaA® Septal Occluder and AmplatzerA® Septal Occluder for Atrial Septal Defect Device Closure
    Roymanee, Supaporn
    Promphan, Worakan
    Tonklang, Nakharin
    Wongwaitaweewong, Kanjarut
    PEDIATRIC CARDIOLOGY, 2015, 36 (05) : 935 - 941
  • [32] Percutaneous Closure of Atrial Septal Defect
    Ben Zekry, Sagit
    Guthikonda, Sasidhar
    Little, Stephen H.
    Nagueh, Sherif F.
    Garcia, Kathleen M.
    Zoghbi, William A.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (04) : 515 - 517
  • [33] Atrial septal defect closure: rethinking device vs surgery
    Shamsher Singh Lohchab
    Sunil Sharma
    Indian Journal of Thoracic and Cardiovascular Surgery, 2021, 37 : 255 - 256
  • [34] Atrial septal defect closure: rethinking device vs surgery
    Lohchab, Shamsher Singh
    Sharma, Sunil
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 37 (03) : 255 - 256
  • [35] Atrial septal defect closure and migraine with aura: is there a correlation?
    Castellini, Paola
    Lambru, Giorgio
    Manzoni, Gian Camillo
    Torelli, Paola
    NEUROLOGICAL SCIENCES, 2009, 30 (04) : 339 - 342
  • [36] Device embolization associated with percutaneous closure of atrial septal defect
    Gur, Ali Kemal
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 21 (04): : 1061 - 1063
  • [37] Transcatheter closure of atrial septal defect in a geriatric population
    Nakagawa, Koji
    Akagi, Teiji
    Taniguchi, Manabu
    Kijima, Yasufumi
    Goto, Keiji
    Kusano, Kengo F.
    Itoh, Hiroshi
    Sano, Shunji
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (01) : 84 - 90
  • [38] Transcatheter atrial septal defect closure guided by colour flow Doppler
    Tzifa, Aphrodite
    Gordon, Justin
    Tibby, Shane M.
    Rosenthal, Eric
    Qureshi, Shakeel A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 149 (03) : 299 - 303
  • [39] Transhepatic device closure of atrial septal defect in children associated with interrupted inferior vena cava
    Dhulipudi, Bhargavi
    Bakhru, Shweta
    Singh, Jagadeesh
    Koneti, Nageswara
    ANNALS OF PEDIATRIC CARDIOLOGY, 2022, 15 (02) : 160 - 163
  • [40] Challenges in Device Closure of Secundum Atrial Septal Defect in Older Patients in Their Fifth Decade and Beyond
    Singhi, Anil K.
    Mahapatra, Soumya K.
    Kumar, Dilip
    Dey, Somnath
    Mishra, Amiya
    De, Arnab
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)